Phase Contrast Microradiography of Mouse Lung Using Synchrotron X-ray: Correlation with Optical Microscopy

被引:6
|
作者
Yong, Hwan Seok [1 ,5 ]
Kang, Eun-Young [1 ]
Kim, Yoon Kyung [1 ]
Woo, Ok Hee [1 ]
Shin, Bong Kyoung [2 ]
Oh, Chil Hwan [3 ]
Je, Jung Ho [4 ]
Han, Heon [5 ]
Seo, Jae Seung [5 ,6 ]
机构
[1] Korea Univ, Guro Hosp, Dept Radiol, Seoul 152703, South Korea
[2] Korea Univ, Guro Hosp, Dept Pathol, Seoul 152703, South Korea
[3] Korea Univ, Guro Hosp, Res Inst Skin Imaging, Seoul 152703, South Korea
[4] Pohang Univ Sci & Technol, Dept Mat Sci & Engn, Pohang, South Korea
[5] Kangwon Natl Univ, Dept Radiol, Coll Med, Chunchon, South Korea
[6] Chung Ang Univ, Coll Med, Dept Radiol, Seoul 156756, South Korea
关键词
Phase contrast microradiography; polychromatic synchrotron X-ray; refraction enhanced imaging; lung; RABBIT LUNGS; INJURY; CT;
D O I
10.3349/ymj.2009.50.3.422
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure. Materials and Methods: Normal mice were used for experiments. Some of the mouse lungs were prepared by the lung fixation-inflation method. The resulting sponge-like inflated lung samples were used for microtomography. The remaining mouse lungs were cut into 10 um sections and were used for microradiography and optical microscopic correlation. The experiments on mouse lung samples were per-formed at the 7B2 beamline of the Pohang Light Source in Korea. Results: Phase contrast X-ray microtomography of inflated lung samples showed individual alveolar structure on 3-D reconstruction. Phase contrast microradiographs of thin lung samples showed microstructure of lung, such as alveoli and bronchioles, and were well correlated with optical microscopic images. Conclusions: The results indicate that the phase contrast X-ray microtomography and microradiography using polychromatic synchrotron X-ray is feasible for evaluation of microstructure of the lung.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 50 条
  • [1] Phase-contrast imaging with synchrotron x-ray for mouse lung
    Chen, ZH
    Pan, L
    Li, G
    Xu, M
    Xu, B
    Zhao, TD
    Chen, WC
    Tang, JT
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 : 83 - 85
  • [2] Dynamic In Vivo Synchrotron Phase-Contrast X-Ray Lung Microscopy
    Bayat, S.
    Fardin, L.
    Mittone, A.
    Larsson, A. S.
    Bravin, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [3] ADVANCES IN MICRORADIOGRAPHY AND X-RAY MICROSCOPY
    MITCHELL, GAG
    JOURNAL OF ANATOMY, 1956, 90 (04) : 598 - 598
  • [4] Phase contrast X-ray tomography using synchrotron radiation
    Bonse, U
    Beckmann, F
    Bartscher, M
    Biermann, T
    Busch, F
    Gunnewig, O
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 108 - 119
  • [5] Phase-Contrast Hard X-ray Microscopy Using Synchrotron Radiation for the Diagnosis of Onychomycosis
    Lee, Onseok
    Ha, Seunghan
    Lee, Gunwoo
    Kim, Jaeyoung
    Huang, Jungyun
    Jin, Kyeongsik
    Oh, Chilhwan
    MICROSCOPY RESEARCH AND TECHNIQUE, 2010, 73 (12) : 1110 - 1114
  • [6] MICRORADIOGRAPHY AS AN APPROACH TO X-RAY MICROSCOPY
    NEWBERRY, SP
    JOURNAL OF APPLIED PHYSICS, 1953, 24 (01) : 114 - 114
  • [7] Phase-contrast hard X-ray microscopy using synchrotron radiation for the properties of skeletal muscle in mouse hind limbs
    Jang, Sanghun
    Lim, Jaehong
    Lee, Onseok
    MICROSCOPY RESEARCH AND TECHNIQUE, 2017, 80 (11) : 1221 - 1228
  • [8] Detection of lung cancer with phase-contrast X-ray imaging using synchrotron radiation
    Liu, Ping
    Sun, Jianqi
    Guan, Yijing
    Zhang, Guilin
    Xu, Lisa Xuemin
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2942 - +
  • [9] Ex vivo imaging of basal cell carcinoma using synchrotron phase-contrast X-ray microscopy
    Son, Sang Wook
    Park, Sang Yong
    Park, Gyu Man
    Ha, Seung Han
    Lee, Gun Woo
    Lee, On Seok
    Hwu, Yeukuang
    Kim, Ae Ree
    Je, Jung Ho
    Oh, Chil Hwan
    SKIN RESEARCH AND TECHNOLOGY, 2008, 14 (01) : 13 - 17
  • [10] Combining optical microscopy, X-ray microradiography and X-ray topography in the study of individual CVD diamond crystallites
    Lang, AR
    Makepeace, APW
    Martineau, PM
    Cooper, MA
    DIAMOND AND RELATED MATERIALS, 1997, 6 (09) : 1226 - 1230