Biomechanical and viscoelastic properties of different posterior meniscal root fixation techniques

被引:21
|
作者
Forkel, Philipp [1 ]
Foehr, Peter [2 ]
Meyer, Johannes C. [1 ]
Herbst, Elmar [1 ]
Petersen, Wolf [3 ]
Brucker, Peter U. [1 ]
Burgkart, Rainer [2 ]
Imhoff, Andreas B. [1 ]
机构
[1] TUM, Dept Orthopaed Sports Med, Ismaninger Str 22, D-81675 Munich, Germany
[2] TUM, Dept Orthopaed, Ismaninger Str 22, D-81675 Munich, Germany
[3] Martin Luther Hosp, Clin Orthopaed & Trauma Surg, Caspar Theyss Str 27-31, D-14193 Berlin, Germany
关键词
Meniscus root fixation; Root tear; ACL; Transtibial; PULL-OUT REPAIR; TEAR;
D O I
10.1007/s00167-016-4237-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the present study was to biomechanically compare three different posterior meniscal root repair techniques. Transtibial fixation of a posterior meniscus root tear (PMRT) combined with an anterior cruciate ligament (ACL) reconstruction via one tunnel only shows similar properties in terms of cyclic loading and load to failure compared with direct anchor fixation. Twenty-eight porcine knees were randomly assigned to 4 groups (n = 7 each): (1) native posterior meniscal root, (2) suture anchor repair, (3) refixation via a tibial ACL tunnel in combination with an interference screw fixation of the ACL graft, and (4) refixation via a tibial ACL tunnel in combination with an interference screw fixation of the ACL graft with an additional extracortical button fixation. The four groups underwent cyclic loading followed by a load-to-failure testing. Construct elongation during 1000 cycles, dynamic stiffness, attenuation, maximum force during load-to-failure testing, and failure mode were recorded. All reconstructions showed a significant lower maximum load (p < 0.0001) compared with the native meniscal root. The elongation for the transtibial fixation via the ACL tunnel without an additional extracortical backup fixation was significantly higher compared with the suture anchor technique (p < 0.0001). The additional use of a backup fixation led to similar results compared with the anchor repair technique. The transtibial refixation of the meniscal root can be combined with an ACL reconstruction using the same tibial bone tunnel. However, an additional extracortical backup fixation is necessary. This might avoid a slippage of suture material and a failure of meniscus root fixation.
引用
收藏
页码:403 / 410
页数:8
相关论文
共 50 条
  • [31] Posterior Meniscal Root Repair With Transtibial Double Tunnel Pullout Technique and Anchor Fixation
    Barnes, Ryan H.
    Hobayan, Grace P.
    Cavendish, Parker A.
    Milliron, Eric M.
    Flanigan, David C.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (07): : E1133 - E1138
  • [32] Biomechanical comparison of C1-2 posterior fixation techniques
    Hott, JS
    Lynch, JJ
    Chamberlain, RH
    Sonntag, VKH
    Crawford, NR
    JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (02) : 175 - 181
  • [33] Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures
    Comstock, CP
    vanderMeulen, MCH
    Goodman, SB
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (08) : 517 - 522
  • [34] A biomechanical analysis of meniscal repair techniques
    Rankin, CC
    Lintner, DM
    Noble, PC
    Paraciv, V
    Greer, E
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (04): : 492 - 497
  • [35] Medial Meniscal Root Avulsion: A Biomechanical Comparison of 4 Different Repair Constructs
    Mitchell, Richard
    Pitts, Ryan
    Kim, Young-Mo
    Matava, Matthew J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (01): : 111 - 119
  • [36] Anterior atlanto-occipital transarticular screw fixation: a biomechanical comparison with posterior fixation techniques
    Xu, Panjie
    Huang, Zhiping
    Xiao, Hang
    Lin, Junyu
    Zhu, Qingan
    Ji, Wei
    JOURNAL OF NEUROSURGERY-SPINE, 2023, 38 (03) : 366 - 371
  • [37] Anterior occiput to axis screw fixation - Part II: A biomechanical comparison with posterior fixation techniques
    Dvorak, MFS
    Sekeramayi, F
    Zhu, QG
    Hoekema, J
    Fisher, C
    Boyd, M
    Goertzen, DJ
    Oxland, TR
    SPINE, 2003, 28 (03) : 239 - 245
  • [38] A biomechanical comparison of different fixation techniques for fractures of the acetabular posterior wall (vol 42, pg 673, 2018)
    Cao, Qiyong
    Jiang, Yu
    Li, Yuneng
    Wang, Hao
    Huan, Yong
    Wu, Xinbao
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (05) : 1277 - 1277
  • [39] Posterior Meniscal Root Repair Using a Meniscal Suture Device
    Rocha de Faria, Jose Leonardo
    Pavao, Douglas Mello
    Menescal Pedrinha, Igor Stefano
    de Sousa, Eduardo Branco
    Guimaraes, Joao Matheus
    Gomes, Berliet Assad
    Mozella, Alan de Paula
    ARTHROSCOPY TECHNIQUES, 2020, 9 (07): : E905 - E912
  • [40] Bone Plug versus Suture Fixation of the Posterior Horn in Medial Meniscal Allograft Transplantation A Biomechanical Study
    Hunt, Stephen
    Kaplan, Kevin
    Ishak, Charbel
    Kummer, Frederick J.
    Meislin, Robert
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2008, 66 (01): : 22 - 26