Successive digestions for pre-concentration and ultra-trace determination of Br and I by plasma-based atomic spectrometry and ion chromatography

被引:10
|
作者
Cauduro, Vitoria H. [1 ]
Doneda, Morgana [1 ]
Barin, Juliano S. [2 ]
Mello, Paola A. [1 ]
Flores, Erico M. M. [1 ]
Picoloto, Rochele S. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Santa Maria, Dept Tecnol & Ciencia Alimentos, BR-97105900 Santa Maria, RS, Brazil
关键词
Bromine determination; Iodine determination; Microwave-induced combustion; ICP-MS; Ion chromatography; Halogen determination; IODINE; BROMINE; FOOD; SHRIMP; FEED;
D O I
10.1016/j.microc.2019.03.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study demonstrates the feasibility of successive digestions as a strategy for Br and I pre-concentration and ultra-trace determination by ion chromatography and plasma-based spectrometric techniques. Digestion and pre-concentration steps were performed by using microwave-induced combustion (MIC), and milk powder samples for adult and infant nutrition were used as an example of application. Samples were pressed as pellets (up to 0.7 g) and combusted in closed quartz vessels pressurized with oxygen. Up to 5 combustion cycles were sequentially performed using the same vessel without changing the absorbing solution. In each cycle, a new filter paper, igniter, and sample pellet (0.7 g) were used allowing digestion and pre-concentration. Ammonium hydroxide solutions (100 to 300 mmol L-1) were evaluated for analytes absorption. Using 300 mmol L-1 NH4OH as absorbing solution, up to 5 digestion cycles (0.7 g each cycle, total mass of 3.5 g) can be applied while keeping a suitable relative standard deviation ( < 5%). The accuracy of the proposed MIC method was evaluated by using a whole milk powder reference material (RM NIST 8435) and results were in agreement with reference values (better than 95%). The digestion efficiency was demonstrated by the low residual carbon in digests ( < 25 mg L-1), allowing Br and I determination virtually free of interferences caused by the presence of dissolved organic matter. The limits of detection (LODs) for Br and I were 1.25 and 0.15 ng g(-1), respectively, which are 5 times lower than the LOD obtained using the conventional MIC method. Taking into account the very low LODs obtained, the proposed sequential digestion and pre-concentration MIC method can be recommended for further Br and I determination in ultra-trace levels by inductively coupled plasma mass spectrometry or even by less sensitive techniques, such as inductively coupled plasma optical emission spectrometry or ion chromatography.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 50 条
  • [41] ANALYSIS OF HIGH-PURITY GRAPHITE FOR TRACE-ELEMENTS BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AFTER CHELATING RESIN PRE-CONCENTRATION
    MAHANTI, HS
    BARNES, RM
    ANALYTICAL CHEMISTRY, 1983, 55 (02) : 403 - 405
  • [42] On-line determination of the trace amount of cobalt(II) in real samples by flame atomic absorption spectrometry method after pre-concentration by modified polyvinyl chloride
    Tahere Zarnoushe Farahani
    Ghadamali Bagherian
    Mansour Arab Chamjangali
    Motahare Ashrafi
    SN Applied Sciences, 2023, 5
  • [43] On-line determination of the trace amount of cobalt(II) in real samples by flame atomic absorption spectrometry method after pre-concentration by modified polyvinyl chloride
    Farahani, Tahere Zarnoushe
    Bagherian, Ghadamali
    Chamjangali, Mansour Arab
    Ashrafi, Motahare
    SN APPLIED SCIENCES, 2023, 5 (07):
  • [44] Ion-association dispersive liquid–liquid microextraction of ultra-trace amount of gold in water samples using Aliquat 336 prior to inductively coupled plasma atomic emission spectrometry determination
    Jalal Hassan
    Naeemeh Zari
    Kourosh Tabar-Heydar
    Seyyed Hamid Ahmadi
    Journal of Analytical Science and Technology, 7
  • [45] Corona discharge ionization ion mobility spectrometry for ultra-trace determination of methamphetamine extracted from urine and plasma samples by dispersive liquid–liquid microextraction
    Parisa Darougheh
    Elham Jazan
    Mohammad R. Rezayat
    Mohammad T. Jafari
    Analytical Sciences, 2022, 38 : 1533 - 1540
  • [46] On-line pre-concentration system for vanadium determination in drinking water using flow injection-inductively coupled plasma atomic emission spectrometry
    Wuilloud, RG
    Salonia, JA
    Gásquez, JA
    Olsina, RA
    Martinez, LD
    ANALYTICA CHIMICA ACTA, 2000, 420 (01) : 73 - 79
  • [47] Ultra-Trace Determination of Co (D†D†) in Real Samples Using Ion Pair-Based Dispersive Liquid-Liquid Microextraction Followed by Electrothermal Atomic Absorption Spectrometry
    Eftekhari, Mohammad
    Javedani-Asleh, Farzaneh
    Chamsaz, Mahmoud
    FOOD ANALYTICAL METHODS, 2016, 9 (07) : 1985 - 1992
  • [48] Determination of Trace Nickel(II) by Inductively Coupled Plasma Mass Spectrometry after Pre-concentration/Separation with Monoclinic Fusiform Nanometer-Size Zirconium Dioxide
    Du Ying-Qiu
    Yin Yi-Dong
    Fan Nai-Ying
    Chen Peng-Gang
    Zhang Xiao-Bo
    Jin Hai-Tao
    Shan Hong
    Qu Qiu-Yao
    Sun Zhi-Bo
    Chen Yue-Xin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (12) : 1890 - 1896
  • [49] Corona discharge ionization ion mobility spectrometry for ultra-trace determination of methamphetamine extracted from urine and plasma samples by dispersive liquid-liquid microextraction
    Darougheh, Parisa
    Jazan, Elham
    Rezayat, Mohammad R.
    Jafari, Mohammad T.
    ANALYTICAL SCIENCES, 2022, 38 (12) : 1533 - 1540
  • [50] Ion-association dispersive liquid-liquid microextraction of ultra-trace amount of gold in water samples using Aliquat 336 prior to inductively coupled plasma atomic emission spectrometry determination
    Hassan, Jalal
    Zari, Naeemeh
    Tabar-Heydar, Kourosh
    Ahmadi, Seyyed Hamid
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2016, 7