Fatigue life enhancement of NiTi rotary endodontic instruments by progressive reciprocating operation

被引:17
|
作者
Shin, C. S. [1 ]
Huang, Y. H. [1 ]
Chi, C. W. [2 ,3 ]
Lin, C. P. [2 ,3 ]
机构
[1] Natl Taiwan Univ, Dept Mech Engn, Taipei 10764, Taiwan
[2] Natl Taiwan Univ, Sch Dent, Grad Inst Clin Dent, Taipei 10764, Taiwan
[3] Natl Taiwan Univ Hosp, Taipei 10048, Taiwan
关键词
cyclic fatigue failure; fatigue life enhancement; fractographic analysis; NiTi endodontic instrument; progressive reciprocation; stationary reciprocation; ROTATING-BENDING FATIGUE; CURVED ROOT CANALS; CYCLIC FATIGUE; SHAPING ABILITY; CLINICAL-USE; PROTAPER; MOVEMENT; MOTION; RESISTANCE; FRACTURE;
D O I
10.1111/iej.12233
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate the effect of reciprocating amplitude and progressive angular increment on fatigue life enhancement of NiTi rotary endodontic instruments. Methodology ProTaper F2 instruments were operated in steel artificial canals with both stationary reciprocating (SR) and progressive reciprocating (PR) motions. The SR motions involved symmetric to and fro reciprocation of +/- 180 degrees, +/- 135 degrees, +/- 90 degrees, +/- 60 degrees and +/- 45 degrees. The PR motions were +/- 45 degrees stationary motion superimposed with angular increments of 7 degrees, 11 degrees, 22.5 degrees or 31 degrees whenever an instrument completed 1, 10 or 30 reciprocating cycles (rc). The fatigue lives were compared with those under continuous rotation (CR) and a reciprocating operation with a forward 144 degrees and backward 72 degrees motion proposed by Yared (2008). The statistical significance of these operating modes on fatigue life was examined using one way ANOVA and post hoc Tukey's tests at P = 0.05. Fractographic analysis was also applied to probe the fracture mechanisms of different rotation motions. Results Fatigue life increased with decreasing reciprocating amplitude. Operating in the SR increased fatigue life by 355% over that in the CR. Except for the 22.5 degrees increment, all PR motions yielded longer fatigue lives than the SR motion. A progressive reciprocating operation with a +/- 45 degrees reciprocating amplitude and a + 7 degrees progressive angular increment every 10 reciprocating cycles (+/- 45 degrees/10rc/+ 7 degrees) increased fatigue life by 990% over that in the CR motion. In terms of life enhancement over the CR motion, the larger the curvature the less are the differences between different movements. Single crack initiation sites were found in the CR and SR motions, while three crack initiation sites were typical in the +/- 45 degrees/10rc/+ 7 degrees motion. Conclusions Fatigue life increased with decreasing reciprocating amplitude in stationary reciprocation. A progressive reciprocating operation with +/- 45 degrees/10rc/ + 7 degrees motion led to significant fatigue life enhancement and multiple fatigue crack initiation in NiTi endodontic instruments.
引用
收藏
页码:882 / 888
页数:7
相关论文
共 50 条
  • [1] Research that matters: studies on fatigue of rotary and reciprocating NiTi root canal instruments
    Huelsmann, Michael
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (10) : 1401 - 1402
  • [2] Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution
    Cheung, Gary S. P.
    Darvell, Brian W.
    [J]. DENTAL MATERIALS, 2008, 24 (06) : 753 - 759
  • [3] Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion
    Gambarini, G.
    Gergi, R.
    Naaman, A.
    Osta, N.
    Al Sudani, D.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (09) : 802 - 806
  • [4] Mechanism of fracture of NiTi superelastic endodontic rotary instruments
    Javier Gil
    Elisa Rupérez
    Eugenio Velasco
    Conrado Aparicio
    José María Manero
    [J]. Journal of Materials Science: Materials in Medicine, 2018, 29
  • [5] Mechanism of fracture of NiTi superelastic endodontic rotary instruments
    Gil, Javier
    Ruperez, Elisa
    Velasco, Eugenio
    Aparicio, Conrado
    Maria Manero, Jose
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2018, 29 (08)
  • [6] Sterilization of rotary NiTi instruments within endodontic sponges
    Chan, H. W. A.
    Tan, K. H.
    Dashper, S. G.
    Reynolds, E. C.
    Parashos, P.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (09) : 850 - 857
  • [7] Torsional fatigue strength of reciprocating and rotary pathfinding instruments manufactured from different NiTi alloys
    Vivan, Rodrigo Ricci
    Alcalde, Murilo Priori
    Candeiro, George
    Gavini, Giulio
    Caldeira, Celso Luis
    Hungaro Duarte, Marco Antonio
    [J]. BRAZILIAN ORAL RESEARCH, 2019, 33
  • [8] Influence of a brushing working motion on the fatigue life of NiTi rotary instruments
    Plotino, G.
    Grande, N. M.
    Sorci, E.
    Malagnino, V. A.
    Somma, F.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (01) : 45 - 51
  • [9] Impact of a modified motion on the fatigue life of NiTi reciprocating instruments: a Weibull analysis
    Francesco Iacono
    Chiara Pirani
    Ana Arias
    Josè C. de la Macorra
    Luigi Generali
    Maria Giovanna Gandolfi
    Carlo Prati
    [J]. Clinical Oral Investigations, 2019, 23 : 3095 - 3102
  • [10] Impact of a modified motion on the fatigue life of NiTi reciprocating instruments: a Weibull analysis
    Iacono, Francesco
    Pirani, Chiara
    Arias, Ana
    de la Macorra, Jose C.
    Generali, Luigi
    Gandolfi, Maria Giovanna
    Prati, Carlo
    [J]. CLINICAL ORAL INVESTIGATIONS, 2019, 23 (07) : 3095 - 3102