Research that matters: studies on fatigue of rotary and reciprocating NiTi root canal instruments

被引:26
|
作者
Huelsmann, Michael [1 ]
机构
[1] UMG, Dept Prevent Dent Periodontol & Cariol, Gottingen, Germany
关键词
ENDODONTIC INSTRUMENTS; TEMPERATURE; RESISTANCE;
D O I
10.1111/iej.13194
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
引用
收藏
页码:1401 / 1402
页数:2
相关论文
共 50 条
  • [1] Fatigue life enhancement of NiTi rotary endodontic instruments by progressive reciprocating operation
    Shin, C. S.
    Huang, Y. H.
    Chi, C. W.
    Lin, C. P.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (09) : 882 - 888
  • [2] Comparison of root canal preparation with two rotary NiTi instruments:: ProFile .04 and GT Rotary
    Roedig, T.
    Huelsmann, M.
    Kahlmeier, C.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (07) : 553 - 562
  • [3] Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion
    Gambarini, G.
    Gergi, R.
    Naaman, A.
    Osta, N.
    Al Sudani, D.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (09) : 802 - 806
  • [4] Torsional fatigue strength of reciprocating and rotary pathfinding instruments manufactured from different NiTi alloys
    Vivan, Rodrigo Ricci
    Alcalde, Murilo Priori
    Candeiro, George
    Gavini, Giulio
    Caldeira, Celso Luis
    Hungaro Duarte, Marco Antonio
    [J]. BRAZILIAN ORAL RESEARCH, 2019, 33
  • [5] Efficacy, cleaning ability and safety of different rotary NiTi instruments in root canal retreatment
    Hülsmann, M
    Bluhm, V
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) : 468 - 476
  • [6] Cyclic fatigue testing of NiTi rotary instruments
    Gambarini, G
    Di Veroli, A
    Floridi, G
    Pittari, A
    De Luca, S
    De Luca, M
    [J]. JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1243 - 1243
  • [7] Efficacy of reciprocating and rotary NiTi instruments for retreatment of curved root canals assessed by micro-CT
    Roedig, T.
    Reicherts, P.
    Konietschke, F.
    Dullin, C.
    Hahn, W.
    Huelsmann, M.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (10) : 942 - 948
  • [8] Design features of rotary root canal instruments
    Rzhanov, Evgueniy A.
    Belyaeva, Tatiana S.
    [J]. ENDO-ENDODONTIC PRACTICE TODAY, 2012, 6 (01): : 29 - 39
  • [9] Quantitative evaluation of root canal surface roughness after filing with adaptive reciprocating and continuous rotary instruments
    Manesh, Vahid Sakhaei
    Giacomin, Paul
    Stoll, Richard
    [J]. MICROSCOPY RESEARCH AND TECHNIQUE, 2017, 80 (06) : 657 - 661
  • [10] Research that matters - root canal filling and leakage studies
    De-Deus, G.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (12) : 1063 - 1064