Percutaneous left ventricular assist in ischemic cardiac arrest

被引:17
|
作者
Tuseth, Vegard [1 ]
Salem, Mohamed [1 ]
Pettersen, Reidar [1 ]
Grong, Ketil [3 ]
Rotevatn, Svein [1 ]
Wentzel-Larsen, Tore [4 ]
Nordrehaug, Jan Erik [1 ,2 ]
机构
[1] Haukeland Hosp, Dept Heart Dis, N-5021 Bergen, Norway
[2] Univ Bergen, Haukeland Univ Hosp, Inst Med, N-5021 Bergen, Norway
[3] Univ Bergen, Dept Surg Sci, Haukeland Univ Hosp, N-5021 Bergen, Norway
[4] Haukeland Hosp, Clin Res Ctr, N-5021 Bergen, Norway
关键词
AMI; cardiac arrest; resuscitation; PCI; LVAD; tissue perfusion; AUTOMATIC MECHANICAL COMPRESSION; PUBLIC-ACCESS DEFIBRILLATION; EXTRACORPOREAL LIFE-SUPPORT; CEREBRAL-BLOOD-FLOW; CARDIOPULMONARY-RESUSCITATION; DEVICE IMPLANTATION; CARBON-DIOXIDE; CLOSED-CHEST; CORONARY INTERVENTION; CARDIOGENIC-SHOCK;
D O I
10.1097/CCM.0b013e31819c0642
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Ischemic cardiac arrest represents a challenge for optimal emergency revascularization therapy. A percutaneous left ventricular assist device (LVAD) may be beneficial. Objective: To determine the effect of a percutaneous LVAD during cardiac arrest without chest compressions and to assess the effect of fluid loading. Design. Totally, 16 pigs randomized to either conventional or intensive fluid with LVAD support during ventricular fibrillation (VF). Setting., Acute experimental trial with pigs under general anesthesia. Subjects: Farm pigs of both sexes. Interventions. After randomization for fluid infusion, VF was induced by balloon occlusion of the proximal left anterior descending artery. LVAD and fluid were started after VF had been induced. Measurements: Brain, kidney, myocardial tissue perfusion, and cardiac index were measured with the microsphere injection technique at baseline, 3, and 15 minutes. Additional hemodynamic monitoring continued until 30 minutes. Main results. At 15 minutes, vital organ perfusion was maintained without significant differences between the two groups. Mean cardiac index at 3 minutes of VF was 1.2 L.min(-1).m(2) (29% of baseline, p < 0.05). Mean perfusion at 3 minutes was 65% in the brain and 74% in the myocardium compared with baseline (p < 0.05), then remained unchanged during the initial 15 minutes. At 30 minutes, LVAD function was sustained in 11 of 16 animals (8 of 8 intensified fluid vs. 3 of 8 conventional fluid) and was associated with intensified fluid loading (p < 0.001). Conclusions. During VF, a percutaneous LVAD may sustain vital organ perfusion. A potential clinical role of the device during cardiac arrest has yet to be established. (Crit Care Mad 2009; 37: 1365-1372)
引用
收藏
页码:1365 / 1372
页数:8
相关论文
共 50 条
  • [41] Percutaneous Stenting of a Left Ventricular Assist Device Outflow Kink
    El Sabbagh, Abdallah
    Al-Hijji, Mohammed
    Gulati, Rajiv
    Rihal, Charanjit S.
    Pollak, Peter M.
    Behfar, Atta
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (24) : E229 - E231
  • [42] Implication of Percutaneous Left Ventricular Assist Device for Takotsubo Syndrome
    Nakamori, Taishi
    Nakamura, Makiko
    Imamura, Teruhiko
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 42 : 6 - 6
  • [43] Clinical Use of Temporary Percutaneous Left Ventricular Assist Devices
    Froesch, Patric
    Martinelli, Michele
    Meier, Pascal
    Cook, Stephane
    Hullin, Roger
    Windecker, Stephan
    Mohacsi, Paul
    Meier, Bernhard
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (02) : 304 - 313
  • [44] Percutaneous Intervention for Left Ventricular Assist Device Outflow Obstruction
    Barac, Yaron D.
    Alwair, Hazim
    DeNino, Walter F.
    Ghadimi, Kamrouz
    Patel, Chetan B.
    Zomorodi, Ali R.
    Long, Chandler
    Schroder, Jacob N.
    Milano, Carmelo A.
    Daneshmand, Mani A.
    HEART LUNG AND CIRCULATION, 2020, 29 (03): : E25 - E27
  • [45] Left Ventricular Assist Device Percutaneous Deactivation With a Watchman Device
    Aoun, Tanous
    Baudry, Guillaume
    Rioufol, Gilles
    Obadia, Jean Francois
    Pozzi, Matteo
    ANNALS OF THORACIC SURGERY, 2021, 112 (02): : E127 - E129
  • [46] Early experience with a percutaneous left ventricular assist device (TandemHeart)
    Windecker, S
    Watson, S
    Carrel, T
    Schmidli, J
    Takala, J
    Hullin, R
    Molhacsi, P
    Meier, B
    EUROPEAN HEART JOURNAL, 2004, 25 : 580 - 581
  • [47] The role of percutaneous left ventricular assist devices during ventricular tachycardia ablation
    Bunch, T. Jared
    Mahapatra, Srijoy
    Reddy, Yeruva Madhu
    Lakkireddy, Dhanunjaya
    EUROPACE, 2012, 14 : II26 - II32
  • [48] Right ventricular failure following placement of a percutaneous left ventricular assist device
    Alkhawam, Hassan
    Rafeedheen, Rahil
    Abo-Salem, Elsayed
    HEART & LUNG, 2019, 48 (02): : 111 - 113
  • [49] RIGHT VENTRICULAR FAILURE FOLLOWING PLACEMENT OF A PERCUTANEOUS LEFT VENTRICULAR ASSIST DEVICE
    Rafeedheen, Rahil
    Abo-Salem, Elsayed
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 2248 - 2248
  • [50] Use of a Percutaneous Left Ventricular Assist Device For High-Risk Cardiac Interventions and Cardiogenic Shock
    Thomas, Joseph L.
    Al-Ameri, Hazim
    Economides, Christina
    Shareghi, Shahrzad
    Abad, Damian Grovas
    Mayeda, Guy
    Burstein, Steven
    Shavelle, David M.
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (08): : 360 - 364