Comparison of density fluctuation measurements between O-mode and X-mode reflectometry on Tore Supra

被引:31
|
作者
Gerbaud, T. [1 ]
Clairet, F.
Sabot, R.
Sirinelli, A.
Heuraux, S.
Leclert, G.
Vermare, L.
机构
[1] CEA Cadarache, EURATOM Assoc, DSM, DRFC, F-13108 St Paul Les Durance, France
[2] Univ Nancy 1, CNRS 7040, Lab Phys Milieux Ionises & Applicat, F-54506 Vandoeuvre Les Nancy, France
[3] Univ Aix Marseille 1, Fac St Jerome, CNRS, UMR 6633,PIIM, F-13397 Marseille 20, France
[4] EURATOM, IPP, Max Planck Inst Plasmaphys, D-85748 Garching, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2006年 / 77卷 / 10期
关键词
D O I
10.1063/1.2354310
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Reflectometry is a versatile diagnostic which allows both electronic density profile and density fluctuation measurements. Fast sweep heterodyne technique is particularly suitable for precise measurement of the phase of the reflected signal, which records the story of the wave propagation through the plasma up to the cutoff layer, including the density fluctuations. The present article exhibits a comparison of the density fluctuation radial profile measurements between fast sweep frequency technique, both using O-mode and X-mode polarizations, and fixed frequency technique. The correct agreement between all measurements of the relative values of the density fluctuation profiles reinforces the validity of the approximations used. (c) 2006 American Institute of Physics.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Comparison of the Effects Induced by the Ordinary (O-Mode) and Extraordinary (X-Mode) Polarized Powerful HF Radio Waves in the High-Latitude Ionospheric F Region
    Blagoveshchenskaya, N. F.
    Borisova, T. D.
    Kalishin, A. S.
    Kayatkin, V. N.
    Yeoman, T. K.
    Haggstrom, I.
    COSMIC RESEARCH, 2018, 56 (01) : 11 - 25
  • [32] Development of Q-band X-mode microwave reflectometry for the measurement of edge density profile
    Yang, Z.
    Cai, Q.
    Zhou, R.
    Zhou, H.
    Zhang, Z.
    Pan, X.
    Ren, X.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [33] Comparison of the effects induced by the ordinary (O-mode) and extraordinary (X-mode) polarized powerful HF radio waves in the high-latitude ionospheric F region
    N. F. Blagoveshchenskaya
    T. D. Borisova
    A. S. Kalishin
    V. N. Kayatkin
    T. K. Yeoman
    I. Häggström
    Cosmic Research, 2018, 56 : 11 - 25
  • [34] Studies on O-mode reflectometry spectra simulations with velocity shear layer
    da Silva, F.
    Heuraux, S.
    Manso, M.
    NUCLEAR FUSION, 2006, 46 (09) : S816 - S823
  • [35] OBSERVATION OF THE M = 1 MODE BY MICROWAVE TRANSMISSION MEASUREMENTS IN TORE SUPRA
    GIRUZZI, G
    SEGUI, JL
    PECQUET, AL
    GIL, C
    NUCLEAR FUSION, 1991, 31 (11) : 2158 - 2162
  • [36] Observation of Electron Density Fluctuations by Using the O-Mode Microwave Imaging Reflectometry (O-MIR) in LHD
    Nagayama, Yoshio
    Yamaguchi, Soichiro
    Shi, Zongbing
    Tsuchiya, Hayato
    Hashimoto, Shigehiro
    Ito, Naoki
    Jiang, Min
    Kuwahara, Daisuke
    Sugito, Shoji
    PLASMA AND FUSION RESEARCH, 2016, 11
  • [37] Reconstruction method of X-mode ultrashort-pulse reflectometry in LHD
    Yokota, Y.
    Mase, A.
    Uchino, K.
    Kogi, Y.
    Tokuzawa, T.
    Kawahata, K.
    Nagayama, Y.
    Hojo, H.
    14TH INTERNATIONAL SYMPOSIUM ON LASER-AIDED PLASMA DIAGNOSTICS (LAPD14), 2010, 227
  • [38] Measurement of Radial Correlation Lengths of Electron Density Fluctuations in Heliotron J Using O-Mode Reflectometry
    Smith, Niels
    Nagasaki, Kazunobu
    Proll, Josefine H. E.
    Okada, Hiroyuki
    Minami, Takashi
    Kado, Shin-ichiro
    Kobayashi, Shinji
    Ohshima, Shinsuke
    Konoshima, Shigeru
    Mizuuchi, Tohru
    Nakamura, Yuji
    Ishizawa, Akihiro
    Tomita, Tsuyoshi
    Fukuda, Takeshi
    Kondo, Yasuto
    PLASMA AND FUSION RESEARCH, 2020, 15
  • [39] Design of an O-mode frequency modulated reflectometry system for the measurement of Alborz Tokamak plasma density profile
    Koohestani, Saeideh
    Amrollahi, Reza
    Moradi, Gholamreza
    FUSION ENGINEERING AND DESIGN, 2016, 113 : 139 - 145
  • [40] Development of dual X-mode Doppler reflectometry system in Heliotron J
    Kondo, Y.
    Ohshima, S.
    Kuwahara, D.
    Inoshita, K.
    Fukuda, T.
    Minami, T.
    Kado, S.
    Kobayashi, S.
    Konoshima, S.
    Mizuuchi, T.
    Okada, H.
    Tomita, T.
    Nagasaki, K.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05):