Performance and reliability testing of an active mooring system for peak load reduction

被引:1
|
作者
Luxmoore, Jamie F. [1 ]
Thies, Philipp R. [1 ]
Grey, Simon [2 ]
Newsam, David [3 ]
Johanning, Lars [1 ]
机构
[1] Univ Exeter, Coll Engn Math & Phys Sci, Penryn Campus, Penryn TR10 9EZ, Cornwall, England
[2] AWS Ocean Energy Ltd, Inverness, Scotland
[3] Teqniqa Syst Ltd, London, England
基金
“创新英国”项目;
关键词
Offshore renewable energy; mooring systems; reliability; performance test; component integrity;
D O I
10.1177/1475090217716859
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Offshore renewable energy systems are generally required to operate in exposed offshore locations for long deployment periods at low cost. This requires innovative new mooring system solutions to go beyond the existing offshore industry designs. A number of novel mooring systems have recently been proposed which decouple mooring line compliance and minimum breaking load, offering multiple benefits to designers. Demonstrating reliability for such highly novel systems where standards do not yet exist is a common problem both for mooring systems specifically and in offshore renewable applications generally. A performance and reliability test method is proposed here and is applied to a novel mooring system, the Intelligent Active Mooring System. The line stiffness and damping properties of Intelligent Active Mooring System can be optimised to the prevailing metocean conditions without compromising minimum breaking load; the pre-tension is also adjustable for tidal range compensation or for service access. The article presents the results of a feasibility study for Intelligent Active Mooring System including detailed, large-scale physical performance tests that demonstrate load reductions under normal operating and extreme sea state conditions. The rationale and findings for an accelerated reliability test regime that quantifies the ultimate load capacity of the component and gives insight into the governing failure modes are also presented. The presented test approach provides assurance for the overall system integrity.
引用
收藏
页码:130 / 140
页数:11
相关论文
共 50 条
  • [21] On Peak Shaving and Load Shifting in Distribution Systems: Cost Saving vs Peak Load Reduction
    Guo, Yifei
    Wang, Zhaoyu
    2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,
  • [22] VALVES - TESTING FOR PEAK PERFORMANCE
    COUGHRAN, MT
    INTECH, 1994, 41 (10) : 58 - 61
  • [23] PEAK LOAD REDUCTION BY PRECONDITIONING BUILDINGS AT NIGHT
    RABL, A
    NORFORD, LK
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1991, 15 (09) : 781 - 798
  • [24] Impact of Electric Vehicles on Peak Load Reduction
    Kim, Insu
    2016 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ASIA-PACIFIC (ITEC ASIA-PACIFIC), 2016, : 514 - 518
  • [25] PEAK-LOAD PRICING AND RELIABILITY UNDER UNCERTAINTY
    KLEINDORFER, PR
    FERNANDO, CS
    JOURNAL OF REGULATORY ECONOMICS, 1993, 5 (01) : 5 - 23
  • [26] UNCERTAIN MARKETS, RELIABILITY AND PEAK-LOAD PRICING
    SAVING, TR
    DEVANY, AS
    SOUTHERN ECONOMIC JOURNAL, 1981, 47 (04) : 908 - 923
  • [27] Environmental Impacts of Grid Connected Photovoltaic System Adapted for Peak Load Reduction in Kuwait
    Ghoneim, Adel A.
    PRES 2012: 15TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2012, 29 : 1213 - 1218
  • [28] Economic Feasibility Study of Rooftop Grid Connected PV System for Peak Load Reduction
    Syafii
    Novizon
    Wati
    Juliandri, Dona
    2018 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTER SCIENCE AND INFORMATICS (EECSI 2018), 2018, : 231 - 235
  • [29] Load forecast for system operation in peak load period
    Jin, Liu
    Jilai, Yu
    Zhuo, Liu
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 4808 - +
  • [30] Performance of low impact development on peak flow reduction in an urban system
    Pampaloni, M.
    Sordo-Ward, A.
    Lompi, M.
    Pacetti, T.
    Zubelzu, S.
    Rodriguez-Sinobas, L.
    Bianucci, P.
    Caporali, E.
    Garrote, L.
    JOURNAL OF THE AMERICAN WATER RESOURCES ASSOCIATION, 2024, 60 (02): : 427 - 441