Effect of patient positioning on carbon-ion therapy planned dose distribution to pancreatic tumors and organs at risk

被引:8
|
作者
Miki, Kentaro [1 ]
Fukahori, Mai [1 ]
Kumagai, Motoki [2 ]
Yamada, Shigeru [1 ]
Mori, Shinichiro [1 ]
机构
[1] Natl Inst Radiol Sci, Res Ctr Charged Particle Therapy, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Natl Canc Ctr East, Res Ctr Innovat Oncol, Particle Therapy Div, 6-5-1 Kashiwa, Chiba 2778577, Japan
关键词
Carbon ion radiotherapy; Dose distribution; Patient positioning; Pancreatic cancer; DOSIMETRIC FEASIBILITY; NORMAL TISSUE; RADIOTHERAPY; IRRADIATION; TRIAL; PRONE;
D O I
10.1016/j.ejmp.2016.12.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Pancreatic tumor treatment dose distribution variations associated with supine and prone patient positioning were evaluated. Methods: A total of 33 patients with pancreatic tumors who underwent CT in the supine and prone positions were analyzed retrospectively. Gross tumor volume (GTV), planning target volume (PTV), and organs at risk (OARs) (duodenum and stomach) were contoured. The prescribed dose of 55.2 Gy (RBE) was planned from four beam angles (0 degrees, 90 degrees, 180 degrees, and 270 degrees). Patient collimator and compensating boli were designed for each field. Dose distributions were calculated for each field in the supine and prone positions. To improve dose distribution, patient positioning was selected from supine or prone for each beam field. Results: Compared with conventional beam angle and patient positioning, D2cc of 1st- 2nd portion of duodenum (D1-D2), 3rd-4th portion of duodenum (D3-D4), and stomach could be reduced to a maximum of 6.4 Gy (RBE), 3.5 Gy (RBE), and 4.5 Gy (RBE) by selection of patient positioning. V10 of D1-D2, D3-D4, and stomach could be reduced to a maximum of 7.2 cc, 11.3 cc, and 11.5 cc, respectively. D95 of GTV and PTV were improved to a maximum of 6.9% and 3.7% of the prescribed dose, respectively. Conclusions: Optimization of patient positioning for each beam angle in treatment planning has the potential to reduce OARs dose maintaining tumor dose in pancreatic treatment. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:38 / 46
页数:9
相关论文
共 50 条
  • [41] Efficacy of carbon-ion radiotherapy and high-dose chemotherapy for patients with unresectable Ewing's sarcoma family of tumors
    Iwata, Shintaro
    Yonemoto, Tsukasa
    Ishii, Takeshi
    Kumagai, Kyoya
    Imai, Reiko
    Hagiwara, Yoko
    Kamada, Tadashi
    Tatezaki, Shin-ichiro
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2013, 18 (06) : 1114 - 1118
  • [42] Four-dimensional Treatment Planning in Layer-Stacking Boost Irradiation for Carbon-Ion Pancreatic Therapy
    Mori, S.
    Shinoto, M.
    Yamada, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S840 - S840
  • [43] Four-dimensional treatment planning in layer-stacking boost irradiation for carbon-ion pancreatic therapy
    Mori, Shinichiro
    Shinoto, Makoto
    Yamada, Shigeru
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 (02) : 258 - 263
  • [44] Dose-volume histogram analysis of brainstem necrosis in head and neck tumors treated using carbon-ion radiotherapy
    Shirai, Katsuyuki
    Fukata, Kyohei
    Adachi, Akiko
    Saitoh, Jun-ichi
    Musha, Atsushi
    Abe, Takanori
    Kanai, Tatsuaki
    Kobayashi, Daijiro
    Shigeta, Yuka
    Yokoo, Satoshi
    Chikamatsu, Kazuaki
    Ohno, Tatsuya
    Nakano, Takashi
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (01) : 36 - 40
  • [45] Secondary Light-Ions in Carbon-Ion Therapy: A GEANT4 Simulation of LET and Dose Contributions
    Johnson, D.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3768 - 3768
  • [46] Bystander effect and abscopal effect in recurrent thymic carcinoma treated with carbon-ion radiation therapy: A case report
    Yan-Shan Zhang
    Yi-He Zhang
    Xiao-Jun Li
    Ting-Chao Hu
    Wei-Zuo Chen
    Xin Pan
    Hong-Yu Chai
    Yan-Cheng Ye
    World Journal of Clinical Cases, 2021, (22) : 6538 - 6543
  • [47] Bystander effect and abscopal effect in recurrent thymic carcinoma treated with carbon-ion radiation therapy: A case report
    Zhang, Yan-Shan
    Zhang, Yi-He
    Li, Xiao-Jun
    Hu, Ting-Chao
    Chen, Wei-Zuo
    Pan, Xin
    Chai, Hong-Yu
    Ye, Yan-Cheng
    WORLD JOURNAL OF CLINICAL CASES, 2021, 9 (22) : 6538 - 6543
  • [48] Up modulation of dose-averaged linear energy transfer by simultaneous integrated boost in carbon-ion radiotherapy for pancreatic carcinoma
    Wang, Weiwei
    Sun, Jiayao
    Zhao, Jingfang
    Cheng, Jingyi
    Jiang, Guo-Liang
    Wang, Zheng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):
  • [49] Evaluation of a Method for Dose Estimations to Moving Pancreatic Tumors Treated with Gated Carbon Ion Beams
    Meschini, G.
    Seregni, M.
    Vai, A.
    Phillips, J.
    Baroni, G.
    Ciocca, M.
    Moline, S.
    Paganetti, H.
    Pella, A.
    Valvo, F.
    Sharp, G.
    Riboldi, M.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [50] Three-dimensional dose-distribution measurement of therapeutic carbon-ion beams using a ZnS scintillator sheet
    Yogo, Katsunori
    Tsuneda, Masato
    Horita, Ryo
    Souda, Hikaru
    Matsumura, Akihiko
    Ishiyama, Hiromichi
    Hayakawa, Kazushige
    Kanai, Tatsuaki
    Yamamoto, Seiichi
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (05) : 825 - 832