Improvement in CT Contrast-To-Noise Ratio in Low Contrast Spherical Simulated Liver Lesions Using Iterative Reconstruction

被引:0
|
作者
Dong, F.
Herts, B.
Baker, M.
Goenka, A.
Primak, A.
机构
关键词
D O I
10.1118/1.4814162
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页数:1
相关论文
共 50 条
  • [21] Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the Liver
    Baker, Mark E.
    Dong, Frank
    Primak, Andrew
    Obuchowski, Nancy A.
    Einstein, David
    Gandhi, Namita
    Herts, Brian R.
    Purysko, Andrei
    Remer, Erick
    Vachani, Neil
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) : 8 - 18
  • [22] Single Atom Detection from Low Contrast-to-Noise Ratio Electron Microscopy Images
    Fatermans, J.
    den Dekker, A. J.
    Muller-Caspary, K.
    Lobato, I.
    O'Leary, C. M.
    Nellist, P. D.
    Van Aert, S.
    PHYSICAL REVIEW LETTERS, 2018, 121 (05)
  • [23] Comparing Contrast-to-Noise Ratio, Signal-to-Noise Ratio, and Image Quality of CT Images Reconstructed With Soft Kernel, Standard Kernel, and Standard Kernel With Adaptive Statistical Iterative Reconstruction 30% Techniques
    Bhosale, P.
    Wagner-Bartak, N.
    Wei, W.
    Kundra, V
    Tamm, E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [24] A practical way to improve contrast-to-noise ratio and quantitation for statistical-based iterative reconstruction in whole-body PET imaging
    Fin, Loic
    Bailly, Pascal
    Daouk, Joel
    Meyer, Marc-Etienne
    MEDICAL PHYSICS, 2009, 36 (07) : 3072 - 3079
  • [25] The effects of iterative reconstruction in CT on low-contrast liver lesion volumetry: a phantom study
    Li, Qin
    Berman, Benjamin P.
    Schumacher, Justin
    Liang, Yongguang
    Gavrielides, Marios A.
    Yang, Hao
    Zhao, Binsheng
    Petrick, Nicholas
    MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [26] Noise Level and Contrast Dependent Behavior of MTF in Iterative Reconstruction CT Imaging
    Jin, H.
    Kim, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3636 - 3637
  • [27] Optimizing Dual-Energy CT Technique for Iodine-Based Compound Contrast-To-Noise Ratio
    Sidky, E.
    Terzioglu, F.
    Phillips, J.
    Bal, G.
    Reiser, I.
    Pan, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E632 - E632
  • [28] ENHANCEMENT OF TUMOR-LIVER CONTRAST-TO-NOISE RATIO WITH GADOBENATE DIMEGLUMINE IN MR-IMAGING OF RATS
    KREFT, BP
    TANIMOTO, A
    STARK, DD
    BABA, Y
    ZHAO, LH
    CHEN, JT
    COMPTON, CC
    FINN, JP
    CAVAGNA, FM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01): : 41 - 49
  • [29] The Use of a Simple Contrast to Noise Ratio (CNR) Metric to Predict Low Contrast Resolution Performance in CT
    Brown, M.
    Zhang, D.
    Branham, T.
    Cody, D.
    Kofler, J.
    McCollough, C.
    Pfeiffer, D.
    Strauss, K.
    Yu, L.
    McNitt-Gray
    MEDICAL PHYSICS, 2009, 36 (06)
  • [30] Impact of Incremental Increase in CT Image Noise on Detection of Low-contrast Hypodense Liver Lesions
    Kanal, Kalpana M.
    Chung, Jonathan H.
    Wang, Jin
    Bhargava, Puneet
    Gunn, Martin L.
    Shuman, William P.
    Stewart, Brent K.
    ACADEMIC RADIOLOGY, 2014, 21 (10) : 1233 - 1239