Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity

被引:3
|
作者
Seim, Caitlyn E. [1 ]
Ritter, Brandon [1 ]
Starner, Thad E. [2 ]
Flavin, Kara [3 ]
Lansberg, Maarten G. [3 ]
Okamura, Allison M. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[2] Georgia Inst Technol, Dept Comp Sci, Atlanta, GA 30332 USA
[3] Stanford Univ, Dept Neurol, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
Wearable computers; Muscles; Vibrations; Spinal cord injury; Performance evaluation; Task analysis; Statistics; Accessibility; design; haptics; patient rehabilitation; stroke; upper limb; user centered design; wearable devices; MUSCLE VIBRATION; ASSISTED MOVEMENT; STROKE; MOTOR; IMPAIRMENT; CHALLENGES; INTENSITY; SENSATION; RECOVERY; DEFICITS;
D O I
10.1109/TNSRE.2022.3174808
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vibratory stimulation may improve post-stroke symptoms such as spasticity; however, current studies are limited by the large, clinic-based apparatus used to apply this stimulation. A wearable device could provide vibratory stimulation in a mobile form, enabling further study of this technique. An initial device, the vibrotactile stimulation (VTS) Glove, was deployed in an eight-week clinical study in which sixteen individuals with stroke used the device for several hours daily. Participants reported wearing the glove during activities such as church, social events, and dining out. However, 69% of participants struggled to extend or insert their fingers to don the device. In a follow-up study, eight individuals with stroke evaluated new VTS device prototypes in a three-round iterative design study with the aims of creating the next generation of VTS devices and understanding features that influence interaction with a wearable device by individuals with impaired upper-limb function. Interviews and interaction tasks were used to define actionable design revisions between each round of evaluation. Our analysis identified six new themes from participants regarding device designs: hand supination is challenging, separate finger attachments inhibit fit and use, fingers may be flexed or open, fabric coverage impacts comfort, a reduced concern for social comfort, and the affected hand is infrequently used. Straps that wrap around the arm and fixtures on the anterior arm were other challenging features. We discuss potential accommodations for these challenges, as well as social comfort. New VTS device designs are presented and were donned in an average time of 48 seconds.
引用
下载
收藏
页码:1277 / 1287
页数:11
相关论文
共 50 条
  • [41] A review on design mechanism for self-adapting upper-limb rehabilitation device on finger
    Singh, Nikhil
    Singh, Ramanpreet
    MATERIALS TODAY-PROCEEDINGS, 2022, 63 : 764 - 768
  • [42] A novel socket design for upper-limb prosthesis
    Sang, Yuanjun
    Li, Xiang
    Gan, Yun
    Su, Daniel
    Luo, Yun
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 881 - 886
  • [43] Design of a Soft Wearable Passive Fitness Device for Upper Limb Resistance Exercise
    Park, Junghoon
    Kim, Jaehong
    Kim, Dong Hyun
    Hwang, Jungsik
    Kim, Youngtae G.
    Hyung, SeungYong
    Ko, Soon-Heum
    Lee, Minhyung
    2022 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2022, : 8488 - 8493
  • [44] EFFICACY AND SAFETY OF INCOBOTULINUMTOXINA FOR UPPER-LIMB OR COMBINED UPPER- AND LOWER-LIMB SPASTICITY IN CHILDREN AND ADOLESCENTS WITH CEREBRAL PALSY: XARA STUDY DESIGN
    Dabrowski, Edward
    Chambers, Henry G.
    Heinen, Florian
    Kanovsky, Petr
    Schroeder, Sebastian
    Dersch, Hanna
    Geister, Thorin L.
    Lehn, Annette
    Martinez-Torres, Francisco J.
    Pulte, Irena
    Gaebler-Spira, Deborah
    TOXICON, 2018, 156 : S19 - S19
  • [45] Successful Treatment of Long-Term, Poststroke, Upper-Limb Spasticity With OnabotulinumtoxinA
    Patel, Atul T.
    PHYSICAL THERAPY, 2011, 91 (11): : 1636 - 1641
  • [46] Lesion Characteristics of Individuals With Upper Limb Spasticity After Stroke
    Cheung, Daniel K.
    Climans, Seth A.
    Black, Sandra E.
    Gao, Fuqiang
    Szilagyi, Gregory M.
    Mochizuki, George
    NEUROREHABILITATION AND NEURAL REPAIR, 2016, 30 (01) : 63 - 70
  • [47] Ubiquitous Human Upper-Limb Motion Estimation using Wearable Sensors
    Zhang, Zhi-Qiang
    Wong, Wai-Choong
    Wu, Jian-Kang
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (04): : 513 - 521
  • [48] Safety and Tolerability of a Wearable, Vibrotactile Stimulation Device for Parkinson's Disease
    Tabacof, Laura
    Braren, Stephen
    Patterson, Taylor
    Fry, Adam
    Putrino, David
    FRONTIERS IN HUMAN NEUROSCIENCE, 2021, 15
  • [49] The biomechanics of wheelchair propulsion in individuals with and without upper-limb impairment
    Finley, MA
    Rasch, EK
    Keyser, RE
    Rodgers, MM
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2004, 41 (3B): : 385 - 394
  • [50] Assessment of task ergonomics with an upper limb wearable device
    Peppoloni, Lorenzo
    Filippeschi, Alessandro
    Ruffaldi, Emanuele
    2014 22ND MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2014, : 340 - 345