Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera

被引:55
|
作者
Roellinghoff, F. [1 ,2 ,3 ,4 ,5 ,6 ,7 ]
Benilov, A. [7 ]
Dauvergne, D. [1 ,2 ,3 ]
Dedes, G. [1 ,2 ,3 ]
Freud, N. [4 ,5 ,6 ]
Janssens, G. [7 ]
Krimmer, J. [1 ,2 ,3 ]
Letang, J. M. [4 ,5 ,6 ]
Pinto, M. [1 ,2 ,3 ]
Prieels, D. [7 ]
Ray, C. [1 ,2 ,3 ]
Smeets, J. [7 ]
Stichelbaut, F. [7 ]
Testa, E. [1 ,2 ,3 ]
机构
[1] Univ Lyon, IPNL, F-69003 Lyon, France
[2] Univ Lyon 1, F-69622 Villeurbanne, France
[3] CNRS IN2P3, UMR 5822, F-69622 Villeurbanne, France
[4] Univ Lyon, CREATIS, F-69622 Lyon, France
[5] Univ Lyon 1, Ctr Leon Berard, France
[6] INSA Lyon, CNRS UMR 5220, INSERMU1044, Ctr Leon Berard, France
[7] Ion Beam Applicat SA, B-1348 Louvain, Belgium
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 05期
关键词
protontherapy; prompt gamma; time-of-flight; VERIFICATION; PATIENT; THERAPY;
D O I
10.1088/0031-9155/59/5/1327
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prompt-gamma profile was measured at WPE-Essen using 160 MeV protons impinging a movable PMMA target. A single collimated detector was used with time-of-flight (TOF) to reduce the background due to neutrons. The target entrance rise and the Bragg peak falloff retrieval precision was determined as a function of incident proton number by a fitting procedure using independent data sets. Assuming improved sensitivity of this camera design by using a greater number of detectors, retrieval precisions of 1 to 2mm (rms) are expected for a clinical pencil beam. TOF improves the contrast-to-noise ratio and the performance of the method significantly.
引用
收藏
页码:1327 / 1338
页数:12
相关论文
共 50 条
  • [31] Real-time beam monitoring in scanned proton therapy
    Klimpki, G.
    Eichin, M.
    Bula, C.
    Rechsteiner, U.
    Psoroulas, S.
    Weber, D. C.
    Lomax, A.
    Meer, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 891 : 62 - 67
  • [32] Two-dimensional measurement of the prompt-gamma distribution for proton dose distribution monitoring
    Han Rim Lee
    Jong Hoon Park
    Han Sung Kim
    Chan Hyeong Kim
    Seonghoon Kim
    Journal of the Korean Physical Society, 2013, 63 : 1385 - 1389
  • [33] Two-dimensional measurement of the prompt-gamma distribution for proton dose distribution monitoring
    Lee, Han Rim
    Park, Jong Hoon
    Kim, Han Sung
    Kim, Chan Hyeong
    Kim, Seonghoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1385 - 1389
  • [34] New algorithm to estimate proton beam range for multi-slit prompt- gamma camera
    Ku, Youngmo
    Jung, Jaerin
    Kim, Chan Hyeong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (09) : 3422 - 3428
  • [35] Prompt gamma detection for range verification in proton therapy
    Kurosawa, Shunsuke
    Kubo, Hidetoshi
    Ueno, Kazuki
    Kabuki, Shigeto
    Iwaki, Satoru
    Takahashi, Michiaki
    Taniue, Kojiro
    Higashi, Naoki
    Miuchi, Kentaro
    Tanimori, Toru
    Kim, Dogyun
    Kim, Jongwon
    CURRENT APPLIED PHYSICS, 2012, 12 (02) : 364 - 368
  • [36] Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters
    Lopes, Patricia Cambraia
    Clementel, Enrico
    Crespo, Paulo
    Henrotin, Sebastien
    Huizenga, Jan
    Janssens, Guillaume
    Parodi, Katia
    Prieels, Damien
    Roellinghoff, Frauke
    Smeets, Julien
    Stichelbaut, Frederic
    Schaart, Dennis R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 6063 - 6085
  • [37] Proton range assessment using prompt gamma monitoring of realistic pencil beam scanning treatments
    Janssens, G.
    Smeets, J.
    Stappen, F. Vander
    Prieels, D.
    Perali, I.
    Clementel, E.
    Hotoiu, L.
    Sterpin, E.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S180 - S181
  • [38] Prompt-gamma track-length estimator with time tagging from proton tracking
    Letang, Jean M.
    Allegrini, Oreste
    Testa, Etienne
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):
  • [39] Prompt Gamma Imaging with a Slit Camera for Real-time Range Control in Proton Therapy: Experimental Validation up to 230 MeV with HICAM and Development of a New Prototype
    Perali, I.
    Celani, A.
    Busca, P.
    Fiorini, C.
    Marone, A.
    Basilavecchia, M.
    Frizzi, T.
    Roellinghoff, F.
    Smeets, J.
    Prieels, D.
    Stichelbaut, F.
    Vander Stappen, F.
    Henrotin, S.
    Benilov, A.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3883 - 3886
  • [40] Assessment of Geant4 Prompt-Gamma Emission Yields in the Context of Proton Therapy Monitoring
    Pinto, Marco
    Dauvergne, Denis
    Freud, Nicolas
    Krimmer, Jochen
    Letang, Jean M.
    Testa, Etienne
    FRONTIERS IN ONCOLOGY, 2016, 6