Optimized acquisition protocols for dynamic cardiac SPECT imaging of rats with 123I-MIBG

被引:0
|
作者
Zan, Yunlong [1 ]
HoukIlk, Rostyslav [2 ]
Huang, Qiu [1 ]
Gullberg, Grant T. [2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[2] Lawrence Berkeley Natl Lab, Berkeley, CA USA
基金
对外科技合作项目(国际科技项目);
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Our previous work in dynamic cardiac SPECT imaging of rats with 123I-MIBG showed that with a slow rotation camera (dual head acquisition with 90s per rotation and a 1s acquisition interval at each angle) we could accurately obtain the time activity curves (TACs) and estimate compartmental model parameters. However, the long acquisition time (usually exceeding 60 rotations) limits the throughput and the animal survival rate. The short acquisition interval (1s) can result in the poor photon statistics which increases the variance of the TACs even though it reduce the bias of the TACs. In this study, we tried to shorten the whole acquisition time, optimize the acquisition time interval at each projection view adaptively, while maintaining the estimation accuracy of the kinetic parameters through computer simulations studies. First, the original blood pool TAC (bTAC) was obtained by averaging the bTACs of 5 WKY rats acquired previously. The tissue TAC (tTAC) was the two-tissue compartmental model output with pre-defined kinetic parameters and the original bTAC as the input. Then we cut off the first n segments of 2s, 5s, 10s, 20s and 30s in the bTAC to mimic the acquisition intervals during the acquisition. The cutoff portions were extrapolated to form new bTACs. The relative entropy of the new bTAC and the original bTAC was calculated to decide the max segment number n that could be tolerable. The same segments were also cut off in the tTAC. Finally, the resultant bTACs and tTACs were truncated with acquisition lengths of 1.5, 3, 4.5, 9, 18, 36, and 72 mins and fit to the twotissue compartment model to estimate the kinetic parameters (K-1, k(2), k(3), k(4)). The Distribution Volume (DV) was calculated from the kinetic parameters. The percentage error (PE) between the estimated parameters and pre-defined parameters were calculated. The results showed that, to match the PE with the original protocol, the kinetic parameter K-1 could be estimated with an acquisition time of 90s with non-uniform acquisition protocols of 2s. The DV could be estimated with an acquisition time of 180s with non-uniform acquisition protocols of 5s.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Dynamic SPECT imaging of 123I-mIBG for early detection of doxorubicin-induced cardiotoxicity in dogs
    Wu, Jing
    Boutagy, Nabil
    Feher, Attila
    Romito, Eva
    Liu, Zhao
    Lin, Shu-fei
    Gallezot, Jean-Dominique
    Kapinos, Michael
    Teng, Jo-ku
    Carson, Richard
    Sinusas, Albert
    Liu, Chi
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [22] Sympathetic reinnervation of cardiac allografts evaluated by 123I-MIBG imaging
    Estorch, M
    Campreciós, M
    Flotats, A
    Marí, C
    Bernà, L
    Catafau, AM
    Ballester, M
    Narula, J
    Carrió, I
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (06) : 911 - 916
  • [23] The impact of acquisition time of planar cardiac 123I-MIBG imaging on the late heart to mediastinum ratio
    Dimitriu-Leen, Aukelien C.
    Gimelli, Alessia
    al Younis, Imad
    Veltman, Caroline E.
    Verberne, Hein J.
    Wolterbeek, Ron
    Zandbergen-Harlaar, Silvia
    Bax, Jeroen J.
    Scholte, Arthur J. H. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (02) : 326 - 332
  • [24] The impact of acquisition time of planar cardiac 123I-MIBG imaging on the late heart to mediastinum ratio
    Aukelien C. Dimitriu-Leen
    Alessia Gimelli
    Imad al Younis
    Caroline E. Veltman
    Hein J. Verberne
    Ron Wolterbeek
    Silvia Zandbergen-Harlaar
    Jeroen J. Bax
    Arthur J. H. A. Scholte
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 326 - 332
  • [25] Drawbacks in Gated Cardiac SPECT with 123I-MIBG: The Influence of Extra-cardiac Activity
    Chaves, S.
    Vieira, T.
    Martins, E.
    Oliveira, A.
    Oliveira, P.
    Teresa, F.
    Pereira, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S617 - S617
  • [26] Prognostic Significance of Cardiac 123I-MIBG SPECT Imaging in Heart Failure Patients With Preserved Ejection Fraction
    Seo, Masahiro
    Yamada, Takahisa
    Tamaki, Shunsuke
    Watanabe, Tetsuya
    Morita, Takashi
    Furukawa, Yoshio
    Kawasaki, Masato
    Kikuchi, Atsushi
    Kawai, Tsutomu
    Nakamura, Jun
    Kayama, Kiyomi
    Kawahira, Masatsugu
    Kimura, Takanari
    Ueda, Kunpei
    Sakamoto, Daisuke
    Sakata, Yasushi
    Fukunami, Masatake
    [J]. JACC-CARDIOVASCULAR IMAGING, 2022, 15 (04) : 655 - 668
  • [27] 123I-MIBG SPECT for Evaluation of Patients with Heart Failure
    Dimitriu-Leen, Aukelien C.
    Seholte, Arthur J. H. A.
    Jacobson, Arnold F.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 : 25S - 30S
  • [28] Bladder wall paraganglioma located using 123I-mIBG SPECT and CT imaging
    Frantellizzi, Viviana
    Pontico, Mariano
    Letizia, Claudio
    De Vincentis, Giuseppe
    [J]. REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2018, 37 (04): : 253 - 254
  • [29] Quantitative 123I-mIBG SPECT/CT in patients with neuroblastoma
    Brady, Samuel
    Shulkin, Barry
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [30] Post surgical 123I-MIBG SPECT/CT in neuroblastoma
    Wartski, Myriam
    Jehanno, Nina
    Cellier, Cecile
    Brisse, Herve
    Alberini, Jean Louis
    Petras, Slavomir
    Schleiermacher, Gudrun
    Michon, Jean
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55