Conventional and modified Schwarzschild objective for EUV lithography: design relations

被引:12
|
作者
Bollanti, S. [1 ]
Di Lazzaro, P. [1 ]
Flora, F. [1 ]
Mezi, L. [1 ]
Murra, D. [1 ]
Torre, A. [1 ]
机构
[1] ENEA UTS Tecnol Fis Avanzate, I-00044 Frascati, Italy
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2006年 / 85卷 / 04期
关键词
D O I
10.1007/s00340-006-2405-9
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The design criteria of a Schwarzschild-type optical system are reviewed in relation to its use as an imaging system in an extreme ultraviolet lithography setup. Both the conventional and the modified reductor imaging configurations are considered, and the respective performances, as far as the geometrical resolution in the image plane is concerned, are compared. In this connection, a formal relation defining the modified configuration is elaborated, refining a rather naive definition presented in an earlier work. The dependence of the geometrical resolution on the image-space numerical aperture for a given magnification is investigated in detail for both configurations. So, the advantages of the modified configuration with respect to the conventional one are clearly evidenced. The results of a semi-analytical procedure are compared with those obtained from a numerical simulation performed by an optical design program. The Schwarzschild objective based system under implementation at the ENEA Frascati Center within the context of the Italian FIRB project for EUV lithography has been used as a model. Best-fit functions accounting for the behaviour of the system parameters vs. the numerical aperture are reported; they can be a useful guide for the design of Schwarzschild objective type optical systems.
引用
收藏
页码:603 / 610
页数:8
相关论文
共 50 条
  • [41] Design method for an aspheric Schwarzschild objective with a low obscuration and an infinite conjugate distance
    Wang, Chao
    Zhang, Tao
    Wang, Weibo
    OPTICS COMMUNICATIONS, 2020, 460
  • [42] The first Italian micro exposure tool for EUV lithography: design guidelines and experimental results
    Flora, F.
    Bollanti, S.
    Di Lazzaro, P.
    Mezi, L.
    Murra, D.
    Torre, A.
    NANOTECH CONFERENCE & EXPO 2009, VOL 1, TECHNICAL PROCEEDINGS: NANOTECHNOLOGY 2009: FABRICATION, PARTICLES, CHARACTERIZATION, MEMS, ELECTRONICS AND PHOTONICS, 2009, : 33 - 36
  • [43] Performance-Based Active Wafer Clamp Design for Wafer Heating Effects in EUV Lithography
    van den Hurk, David
    Weiland, Siep
    van Berkel, Koos
    IEEE TRANSACTIONS ON SEMICONDUCTOR MANUFACTURING, 2020, 33 (03) : 424 - 432
  • [44] Design and performance of EUV resist containing photoacid generator for sub-100 nm lithography
    Thiyagarajan, M
    Gonsalves, KE
    Dean, K
    Sykes, ECH
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2005, 5 (07) : 1181 - 1183
  • [45] Grouping design method of catadioptric projection objective for deep ultraviolet lithography
    Cao, Zhen
    Li, Yanqiu
    Mao, Shanshan
    OPTICAL ENGINEERING, 2017, 56 (02)
  • [46] Robust design of broadband EUV multilayer using multi-objective evolutionary algorithm
    Kuang, Shang-qi
    Gong, Xue-peng
    Yang, Hai-gui
    OPTICS COMMUNICATIONS, 2018, 410 : 805 - 810
  • [47] Design of a high transmission illumination optics for anamorphic EUV lithography optics using deep reinforcement learning
    Li, Tong
    Chen, Yuqing
    Li, Yanqiu
    Liu, Lihui
    OPTICS EXPRESS, 2025, 33 (02): : 2261 - 2276
  • [48] New developments in the design of ring-field projection cameras for EUV lithography: passive pupil correction
    Sasian, JM
    INTERNATIONAL OPTICAL DESIGN CONFERENCE 1998, 1998, 3482 : 658 - 663
  • [49] Extreme ultraviolet lithography objective design based on grouping and graphical user interface
    State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun
    Jilin
    130033, China
    Guangxue Xuebao, 12
  • [50] A MODIFIED OBJECTIVE FUNCTION AND A FAST ALGORITHM FOR DESIGN CENTERING
    AGNEW, D
    IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS, 1982, 129 (04): : 110 - 114