Cell-free measurements of brightness of fluorescently labeled antibodies

被引:4
|
作者
Zhou, Haiying [1 ]
Tourkakis, George [1 ]
Shi, Dennis [1 ]
Kim, David M. [1 ]
Zhang, Hairong [1 ]
Du, Tommy [1 ]
Eades, William C. [2 ,3 ]
Berezin, Mikhail Y. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Med, St Louis, MO 63110 USA
[3] Washington Univ, Siteman Canc Ctr Flow Cytometry Core, Sch Med, St Louis, MO 63110 USA
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
基金
美国国家科学基金会;
关键词
MONOCLONAL-ANTIBODIES; PROBES; DYE;
D O I
10.1038/srep41819
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Validation of imaging contrast agents, such as fluorescently labeled imaging antibodies, has been recognized as a critical challenge in clinical and preclinical studies. As the number of applications for imaging antibodies grows, these materials are increasingly being subjected to careful scrutiny. Antibody fluorescent brightness is one of the key parameters that is of critical importance. Direct measurements of the brightness with common spectroscopy methods are challenging, because the fluorescent properties of the imaging antibodies are highly sensitive to the methods of conjugation, degree of labeling, and contamination with free dyes. Traditional methods rely on cell-based assays that lack reproducibility and accuracy. In this manuscript, we present a novel and general approach for measuring the brightness using antibody-avid polystyrene beads and flow cytometry. As compared to a cell-based method, the described technique is rapid, quantitative, and highly reproducible. The proposed method requires less than ten microgram of sample and is applicable for optimizing synthetic conjugation procedures, testing commercial imaging antibodies, and performing high-throughput validation of conjugation procedures.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Study of lipid rafts by gel filtration combined with preliminary staining with fluorescently labeled antibodies
    M. P. Krutikova
    G. I. Krotov
    V. G. Zgoda
    A. V. Filatov
    Biochemistry (Moscow) Supplement Series A: Membrane and Cell Biology, 2007, 1 (3) : 219 - 227
  • [22] Calibration of cell-free DNA measurements by next-generation sequencing
    Hoerres, Derek
    Dai, Qunsheng
    Elmore, Sandra
    Sheth, Siddharth
    Gupta, Gaorav P.
    Kumar, Sunil
    Gulley, Margaret L.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2023, 160 (03) : 314 - 321
  • [24] PARTIAL CHARACTERIZATION OF PROTEIN LABELED IN A CELL-FREE SYSTEM FROM BACILLUS CEREUS 569
    ATHERLY, AG
    IMSANDE, J
    BIOCHIMICA ET BIOPHYSICA ACTA, 1967, 145 (02) : 491 - &
  • [25] INTERACTION OF FLUORESCENTLY-LABELED CONTRACTILE PROTEINS WITH THE CYTOSKELETON IN CELL MODELS
    SANGER, JW
    MITTAL, B
    SANGER, JM
    JOURNAL OF CELL BIOLOGY, 1984, 99 (03): : 918 - 928
  • [26] Detection of Infertility-related Neutralizing Antibodies with a Cell-free Microfluidic Method
    Eyer, Klaus
    Root, Katharina
    Verboket, Pascal E.
    Dittrich, Petra S.
    SCIENTIFIC REPORTS, 2015, 5
  • [27] Detection of Infertility-related Neutralizing Antibodies with a Cell-free Microfluidic Method
    Klaus Eyer
    Katharina Root
    Pascal E. Verboket
    Petra S. Dittrich
    Scientific Reports, 5
  • [28] A RADIOIMMUNOASSAY WITH MONOCLONAL-ANTIBODIES FOR THE DETECTION OF ANTIGENIC CELL-FREE FC RECEPTOR
    RAN, M
    DUX, Z
    ANAVI, R
    SMORODINSKY, NI
    WITZ, IP
    JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 68 (1-2) : 275 - 284
  • [29] Cell-free riboswitches
    Tabuchi, Takeshi
    Yokobayashi, Yohei
    RSC CHEMICAL BIOLOGY, 2021, 2 (05): : 1430 - 1440
  • [30] Cell-Free Bioprocessing
    Swartz, James R.
    CHEMICAL ENGINEERING PROGRESS, 2013, 109 (11) : 40 - 45