Analysis of human hippocampus gangliosides by fully-automated chip-based nanoelectrospray tandem mass spectrometry

被引:44
|
作者
Vukelic, Zeljka
Zarei, Mostafa
Peter-Katalinic, Jasna
Zamfir, Alina D. [1 ]
机构
[1] Univ Munster, Inst Med Phys & Biophys, Munster, Germany
[2] Univ Zagreb, Fac Med, Dept Chem & Biochem, Zagreb 41000, Croatia
[3] Natl Inst Res & Dev Electrochem & Condensed Matte, Timisoara, Romania
关键词
microfluidics; electrospray ionization; gangliosides; hippocampus;
D O I
10.1016/j.chroma.2006.05.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Modem microfluidic devices are currently introduced in electrospray (ESI) mass spectrometry (MS), tending to substitute the classical capillary-based ESI infusion. Automated systems using the combination of robotized sample handling and chip-based ESI are significantly increasing the analysis reproducibility, precision, throughput, and efficiency. In the last couple of years our group developed the chip-based ESI-MS approach for glycomics in biomedical research and applied it for oligosaccharide, glycopeptide and ganglioside investigation. Here we report upon the optimization and application of this modem technique for the analysis of differential ganglioside expression patterns in human fetal and adult hippocampus. By this methodology, ganglioside species exhibiting high degree of heterogeneity in the ceramide motifs and biologically-relevant modifications could be identified in human hippocampus. The ultra-high reproducibility of the experiments uniquely provided by the chip-ESI approach allowed for a reliable MS-based ganglioside comparative assay. Moreover, the particular feature of chip ESI-tandem MS to provide structural information at high sensitivity was useful for detailed characterization of hippocampus-associated species. The experimental data presented in this study indicate the benefits of microfluidic/MS for determination of the topospecific brain ganglioside composition and development-related changes in their expression, which might be of high Value in clinical investigation and for studies related to ganglioside-based therapy of central nervous system diseases. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:238 / 245
页数:8
相关论文
共 50 条
  • [21] Profiling and sequencing of gangliosides from human caudate nucleus by chip-nanoelectrospray mass spectrometry
    Serb, Alina F.
    Sisu, Eugen
    Vukelic, Zeljka
    Zamfir, Alina D.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (12): : 1561 - 1570
  • [22] Chip-nanoelectrospray quadrupole time-of-flight tandem mass spectrometry of meningioma gangliosides: A preliminary study
    Schiopu, Catalin
    Vukelic, Zeljka
    Capitan, Florina
    Kalanj-Bognar, Svjetlana
    Sisu, Eugen
    Zamfir, Alina D.
    ELECTROPHORESIS, 2012, 33 (12) : 1778 - 1786
  • [23] Validating regulatory-compliant wide dynamic range bioanalytical assays using chip-based nanoelectrospray tandem mass spectrometry
    Wickremsinhe, ER
    Ackermann, BL
    Chaudhary, AK
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (01) : 47 - 56
  • [24] Spatially Resolved Protein Hydrogen Exchange Measured by Subzero-Cooled Chip-Based Nanoelectrospray Ionization Tandem Mass Spectrometry
    Amon, Sabine
    Trelle, Morten B.
    Jensen, Ole N.
    Jorgensen, Thomas J. D.
    ANALYTICAL CHEMISTRY, 2012, 84 (10) : 4467 - 4473
  • [25] Analysis of oversulfation in biglycan chondroitin/dermatan sulfate oligosaccharides by chip-based nanoelectrospray ionization multistage mass spectrometry
    Flangea, Corina
    Sisu, Eugen
    Seidler, Daniela G.
    Zamfir, Alina D.
    ANALYTICAL BIOCHEMISTRY, 2012, 420 (02) : 155 - 162
  • [26] Automated chip-based nanoelectrospray-mass spectrometry for rapid identification of proteins separated by two-dimensional gel electrophoresis
    Zhang, S
    Van Pelt, CK
    Henion, JD
    ELECTROPHORESIS, 2003, 24 (21) : 3620 - 3632
  • [27] Fully automated chip-based nanoelectrospray ionization-mass spectrometry as an effective tool for rapid and high-throughput screening of 5 alpha-reductase inhibitors
    Zheng, Ruirong
    Li, Linnan
    Deng, Xueli
    Tian, Mei
    Wang, Zhengtao
    Yang, Li
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (07) : 1685 - 1692
  • [28] Chip-based genotyping by mass spectrometry
    Tang, K
    Fu, DJ
    Julien, D
    Braun, A
    Cantor, CR
    Köster, H
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (18) : 10016 - 10020
  • [29] Fully automated liquid extraction-based surface sampling and ionization using a chip-based robotic nanoelectrospray platform
    Kertesz, Vilmos
    Van Berkel, Gary J.
    JOURNAL OF MASS SPECTROMETRY, 2010, 45 (03): : 252 - 260
  • [30] A fully automated nanoelectrospray tandem mass spectrometric method for analysis of Caco-2 samples
    Van Pelt, CK
    Zhang, S
    Fung, E
    Chu, IH
    Liu, TT
    Li, C
    Korfmacher, WA
    Henion, J
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (14) : 1573 - 1578