Accurate in vivo measurement of polyethylene wear in total knee arthroplasty

被引:18
|
作者
Hoshino, A
Fukuoka, Y
Ishida, A
机构
[1] Kawaguchi Kohgyo Gen Hosp, Dept Orthopaed Surg, Kawaguchi, Saitama 3320031, Japan
[2] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Tokyo, Japan
来源
JOURNAL OF ARTHROPLASTY | 2002年 / 17卷 / 04期
关键词
total knee arthroplasty (TKA); polyethylene wear; computer vision; three-dimensional (3D)/two-dimensional (2D) matching;
D O I
10.1054/arth.2002.32172
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study describes a new technique to evaluate accurate linear polyethylene wear and reports the in vivo annual linear wear rate in total knee arthroplasty. Patients (n = 69) were assessed using a single standing anteroposterior radiograph with 8 reference markers around the knee, where 3-dimensional OD) locations of markers and 3D geometry of the implant were known. By matching the 3D locations of the markers and their projected points on the radiograph, 3D/2D transformation parameters were estimated. Using these parameters, the 3D coordinates of the implant were estimated from the projected x-ray silhouette. After calculating the temorotibial shortest distance, wear and creep deformity of the polyethylene was defined with all accuracy of 0.1 mm or better. Measured linear wear in the 69 knees varied from 0 mm (1 month postoperatively) to 2.71 min (7 years postoperatively). The correlation of linear wear (Y) and year (X) was Y = 0.23 X -0.11 (P<.001). This Study revealed that annual wear rate was 0.23 mm and 2 times greater than the average annual wear rate in total hip arthroplasties.
引用
收藏
页码:490 / 496
页数:7
相关论文
共 50 条
  • [1] In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty
    Goldvasser, Dov
    Hansen, Viktor J.
    Noz, Marilyn E.
    Maguire, Gerald Q., Jr.
    Zeleznik, Michael P.
    Olivecrona, Henrik
    Bragdon, Charles R.
    Weidenhielm, Lars
    Malchau, Henrik
    [J]. ACTA ORTHOPAEDICA, 2014, 85 (03) : 271 - 275
  • [2] In Vivo Measurement of Polyethylene Wear in Cementless Total Hip Arthroplasty
    Roth, A.
    Sander, K.
    Layher, F.
    Babisch, J.
    Venbrocks, R.
    [J]. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (01) : 13 - 17
  • [3] A simple radiographic measurement method for polyethylene wear in total knee arthroplasty
    Fukuoka, Y.
    Hoshino, A.
    Ishida, A.
    [J]. IEEE Transactions on Rehabilitation Engineering, 1999, 7 (02): : 228 - 233
  • [4] EFFECT OF POLYETHYLENE QUALITY ON WEAR IN TOTAL KNEE ARTHROPLASTY
    TANNER, MG
    WHITESIDE, LA
    WHITE, SE
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 83 - 88
  • [5] Factors affecting polyethylene wear in total knee arthroplasty
    Kuster, MS
    Stachowiak, GW
    [J]. ORTHOPEDICS, 2002, 25 (02) : S235 - S242
  • [6] Potentialities of Wear Measurement in Total Knee Arthroplasty
    Pochmon, M.
    Roessler, T.
    Gallo, J.
    Hrabovsky, M.
    Mandat, D.
    Havranek, V.
    [J]. 14TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS, 2008, 20 : 390 - +
  • [7] Prediction of total knee arthroplasty polyethylene wear using the wear index
    Miura, H
    Higaki, H
    Nakanishi, Y
    Mawatari, T
    Moro-oka, T
    Murakami, T
    Iwamoto, Y
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (06): : 760 - 766
  • [8] Wear in total knee arthroplasty—just a question of polyethylene?Metal ion release in total knee arthroplasty
    Jan Philippe Kretzer
    Joern Reinders
    Robert Sonntag
    Sebastien Hagmann
    Marcus Streit
    Sebastian Jeager
    Babak Moradi
    [J]. International Orthopaedics, 2014, 38 : 335 - 340
  • [9] Measurement of polyethylene wear in cementless total hip arthroplasty
    Shih, CH
    Lee, PC
    Chen, JH
    Tai, CL
    Chen, LF
    Wu, JSS
    Chang, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (03): : 361 - 365
  • [10] Arthroscopy for evaluation of polyethylene wear after total knee arthroplasty
    Kondo, Makoto
    Fujii, Tadashi
    Kitagawa, Hiroshi
    Tsumura, Hiroshi
    Kadoya, Yoshinori
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2008, 13 (05) : 433 - 437