Measurement of polyethylene wear in cementless total hip arthroplasty

被引:50
|
作者
Shih, CH [1 ]
Lee, PC [1 ]
Chen, JH [1 ]
Tai, CL [1 ]
Chen, LF [1 ]
Wu, JSS [1 ]
Chang, WH [1 ]
机构
[1] CHANG GUNG MED COLL, TAIPEI, TAIWAN
来源
关键词
D O I
10.1302/0301-620X.79B3.6630
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We made a clinical study of polyethylene wear in 240 hips of 187 patients having primary total hip arthroplasties from 1989 to 1990, using uncemented Osteonics components, with a head size of 26 mm, We excluded cups with anteversion of over 20 degrees and measured linear wear by a new method using a digitiser and special software of our design, Follow-up was from two to five years (mean 4.3). The mean age at operation was 50.3 years, with more men than women (1.4:1). The mean linear wear per year was 0.15 mm; this did not increase with the longevity of the prosthesis (p = 0.54), In 59 hips showing evidence of osteolysis, the mean linear wear rate was significantly higher at 0.23 mm/year (p < 0.001). The mean linear wear rate also correlated significantly with age at the time of operation (p = 0.008), but we found no significant correlations with body-weight, gender, aetiology of the disease, thickness of polyethylene, or cup position. Our new method of measurement is time-saving and reproducible. The results confirm the greater rate of linear wear of polyethylene in patients showing osteolysis and in those who are younger.
引用
收藏
页码:361 / 365
页数:5
相关论文
共 50 条
  • [1] In Vivo Measurement of Polyethylene Wear in Cementless Total Hip Arthroplasty
    Roth, A.
    Sander, K.
    Layher, F.
    Babisch, J.
    Venbrocks, R.
    [J]. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (01) : 13 - 17
  • [2] Increased polyethylene wear after cementless ABG I total hip arthroplasty
    Karl-Stefan Delank
    Philipp Drees
    Nicole Menzel
    Torsten Hansen
    Heinz Duschner
    Anke Eckardt
    [J]. Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 509 - 516
  • [3] Increased polyethylene wear after cementless ABG I total hip arthroplasty
    Delank, Karl-Stefan
    Drees, Philipp
    Menzel, Nicole
    Hansen, Torsten
    Duschner, Heinz
    Eckardt, Anke
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (08) : 509 - 516
  • [4] Late dislocations after cementless total hip arthroplasty resulting from polyethylene wear
    Orozco, F
    Hozack, WJ
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (08): : 1059 - 1063
  • [5] In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty
    Goldvasser, Dov
    Hansen, Viktor J.
    Noz, Marilyn E.
    Maguire, Gerald Q., Jr.
    Zeleznik, Michael P.
    Olivecrona, Henrik
    Bragdon, Charles R.
    Weidenhielm, Lars
    Malchau, Henrik
    [J]. ACTA ORTHOPAEDICA, 2014, 85 (03) : 271 - 275
  • [6] The Relationship between Acetabular Osteolytic Lesion Volume and Polyethylene Wear in Cementless Total Hip Arthroplasty
    Kitamura, N.
    Hopper, R. H.
    Leung, S. B.
    Engh, C. A., Jr.
    Engh, Ch. A.
    [J]. BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 209 - 218
  • [7] Early polyethylene wear and osteolysis in cementless total hip arthroplasty - The influence of femoral head size and polyethylene thickness
    Lee, PC
    Shih, CH
    Chen, WJ
    Tu, YK
    Tai, CL
    [J]. JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 976 - 981
  • [8] POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY
    BANKSTON, AB
    CATES, H
    RITTER, MA
    KEATING, EM
    FARIS, PM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 7 - 13
  • [9] Radiologic evaluation of polyethylene wear of cementless total hip endoprosthesis
    Sander, K
    Roth, A
    Layher, F
    Babisch, J
    Venbrocks, R
    [J]. BIOMEDIZINISCHE TECHNIK, 2003, 48 (12): : 344 - 348
  • [10] Thigh mass associated with polyethylene wear-induced osteolysis after cementless total hip arthroplasty
    Youn-Soo Park
    Seung-Jae Lim
    Jin-Hong Kim
    Ajay Wala
    [J]. Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1097 - 1101