Pulsatile blood flow in large arteries: comparative study of Burton's and McDonald's models

被引:14
|
作者
Gayathri, K. [1 ]
Shailendhra, K. [1 ]
机构
[1] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Math, Coimbatore 641112, Tamil Nadu, India
关键词
hemodynamics; wall shear stress (WSS); oscillatory shear index (OSI); realistic pressure gradient; Beavers and Joseph (BJ) slip condition; femoral; brachial; pulmonary artery; LEFT CORONARY-ARTERY; WALL SHEAR-STRESS; ABDOMINAL-AORTA; HEMODYNAMICS; ATHEROSCLEROSIS; BIFURCATION; SIMULATION; PRESSURE;
D O I
10.1007/s10483-014-1814-7
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
To get a clear picture of the pulsatile nature of blood flow and its role in the pathogenesis of atherosclerosis, a comparative study of blood flow in large arteries is carried out using the two widely used models, McDonald's and Burton's models, for the pressure gradient. For both models, the blood velocity in the lumen is obtained analytically. Elaborate investigations on the wall shear stress (WSS) and oscillatory shear index (OSI) are carried out. The results are in good agreement with the available data in the literature. The superiority of McDonald's model in capturing the pulsatile nature of blood flow, especially the OSI, is highlighted. The present investigation supports the hypothesis that not only WSS but also OSI are the essential features determining the pathogenesis of atherosclerosis. Finally, by reviewing the limitations of the present investigation, the possibility of improvement is explored.
引用
收藏
页码:575 / 590
页数:16
相关论文
共 50 条
  • [41] PULSATILE FLOW IN TAPERED TUBES - A MODEL OF BLOOD-FLOW WITH LARGE DISTURBANCES
    KIMMEL, E
    DINNAR, U
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02): : 112 - 119
  • [42] KFC and McDonald's-Models of Blended Culture
    QIU JIANGHONG
    China Today, 2004, (06) : 26 - 28
  • [43] NUMERICAL STUDY OF PULSATILE FLOW THROUGH STENOSED CANINE FEMORAL ARTERIES
    DALY, BJ
    JOURNAL OF BIOMECHANICS, 1976, 9 (07) : 465 - 475
  • [44] Comparative analysis of pulsatile nanofluid flow under slip conditions through stenosed arteries
    Dawood, A. S.
    Kroush, Faisal A.
    Abumandour, Ramzy M.
    Eldesoky, Islam M.
    BOUNDARY VALUE PROBLEMS, 2025, 2025 (01):
  • [46] THE EFFECT OF CHANGES IN BLOOD FLOW ON THE CALIBRE OF LARGE ARTERIES
    DSILVA, JL
    FOUCHE, RF
    JOURNAL OF PHYSIOLOGY-LONDON, 1960, 150 (03): : P23 - P24
  • [47] On the different etiologies of isolated myelitis: a McDonald's 2010 and 2017 criteria comparative study
    Oses, M.
    Acebron Sanchez-Herrera, F.
    Querejeta Coma, A.
    Escribano-Paredes, B.
    Corral, I.
    Ginestal Lopez, R.
    Zamarbide, I.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 191 - 191
  • [48] One-dimensional models for blood flow in arteries
    Luca Formaggia
    Daniele Lamponi
    Alfio Quarteroni
    Journal of Engineering Mathematics, 2003, 47 : 251 - 276
  • [49] One-dimensional models for blood flow in arteries
    Formaggia, L
    Lamponi, D
    Quarteroni, A
    JOURNAL OF ENGINEERING MATHEMATICS, 2003, 47 (3-4) : 251 - 276
  • [50] Two -fluid nonlinear mathematical model for pulsatile blood flow through catheterized arteries
    D. S. Sankar
    Usik Lee
    Journal of Mechanical Science and Technology, 2009, 23 : 1650 - 1669