Pulsatile blood flow in large arteries: comparative study of Burton's and McDonald's models

被引:14
|
作者
Gayathri, K. [1 ]
Shailendhra, K. [1 ]
机构
[1] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Math, Coimbatore 641112, Tamil Nadu, India
关键词
hemodynamics; wall shear stress (WSS); oscillatory shear index (OSI); realistic pressure gradient; Beavers and Joseph (BJ) slip condition; femoral; brachial; pulmonary artery; LEFT CORONARY-ARTERY; WALL SHEAR-STRESS; ABDOMINAL-AORTA; HEMODYNAMICS; ATHEROSCLEROSIS; BIFURCATION; SIMULATION; PRESSURE;
D O I
10.1007/s10483-014-1814-7
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
To get a clear picture of the pulsatile nature of blood flow and its role in the pathogenesis of atherosclerosis, a comparative study of blood flow in large arteries is carried out using the two widely used models, McDonald's and Burton's models, for the pressure gradient. For both models, the blood velocity in the lumen is obtained analytically. Elaborate investigations on the wall shear stress (WSS) and oscillatory shear index (OSI) are carried out. The results are in good agreement with the available data in the literature. The superiority of McDonald's model in capturing the pulsatile nature of blood flow, especially the OSI, is highlighted. The present investigation supports the hypothesis that not only WSS but also OSI are the essential features determining the pathogenesis of atherosclerosis. Finally, by reviewing the limitations of the present investigation, the possibility of improvement is explored.
引用
收藏
页码:575 / 590
页数:16
相关论文
共 50 条
  • [1] Pulsatile blood flow in large arteries: comparative study of Burton’s and McDonald’s models
    K. Gayathri
    K. Shailendhra
    Applied Mathematics and Mechanics, 2014, 35 : 575 - 590
  • [2] Pulsatile blood flow in large arteries:comparative study of Burton's and McDonald's models
    K.GAYATHRI
    K.SHAILENDHRA
    Applied Mathematics and Mechanics(English Edition), 2014, 35 (05) : 575 - 590
  • [3] Pulsatile Flow of Two-Fluid Nonlinear Models for Blood Flow through Catheterized Arteries: A Comparative Study
    Sankar, D. S.
    Lee, Usik
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2010, 2010
  • [4] Pulsatile Blood Flow through Large Arteries with BJR Slip Condition
    Thiagarajan, Vinod
    Purushothaman, Roopesh Kumar
    Srikumar
    Shailendhra, K.
    Gayathri, K.
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 1700 - 1705
  • [5] Numerical study of nonlinear pulsatile flow in S-shaped curved arteries
    Qiao, AK
    Guo, XL
    Wu, SG
    Zeng, YJ
    Xu, XH
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (07) : 545 - 552
  • [6] AN ANALYSIS MODEL OF PULSATILE BLOOD FLOW IN ARTERIES
    柳兆荣
    徐刚
    陈泳
    滕忠照
    覃开蓉
    Applied Mathematics and Mechanics(English Edition), 2003, (02) : 230 - 240
  • [7] Impact of hematocrit on pulsatile blood flow in stenosed arteries: a computational study in healthy, diabetic, and anemic models
    Behir, Badreddine
    Benslimane, Abdelhakim
    Mehdaoui, Hamza
    Mehdi, Boukhari
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [8] An analysis model of pulsatile blood flow in arteries
    Liu Zhao-rong
    Xu Gang
    Chen Yong
    Teng Zhong-zhao
    Qin Kai-rong
    Applied Mathematics and Mechanics, 2003, 24 (2) : 230 - 240
  • [9] An analysis model of pulsatile blood flow in arteries
    Liu, ZR
    Xu, G
    Chen, Y
    Teng, ZZ
    Qin, KR
    APPLIED MATHEMATICS AND MECHANICS-ENGLISH EDITION, 2003, 24 (02) : 230 - 240
  • [10] Two-Fluid Mathematical Models for Blood Flow in Stenosed Arteries: A Comparative Study
    Sankar, D. S.
    Ismail, Ahmad Izani Md.
    BOUNDARY VALUE PROBLEMS, 2009, : 1 - 15