A study of planning dose constraints for treatment of nasopharyngeal carcinoma using a commercial inverse treatment planning system

被引:27
|
作者
Xia, P [1 ]
Lee, N [1 ]
Liu, YM [1 ]
Poon, I [1 ]
Weinberg, V [1 ]
Shin, E [1 ]
Quivey, JM [1 ]
Verhey, LJ [1 ]
机构
[1] Univ Calif San Francisco, Ctr Comprehens Canc, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
intensity-modulated radiotherapy; head-and-neck cancer; inverse planning; optimization;
D O I
10.1016/j.ijrobp.2004.02.040
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to develop and test planning dose constraint templates for tumor and normal structures in the treatment of nasopharyngeal carcinoma (NPC) using a specific commercial inverse treatment planning system. Methods and Materials: Planning dose constraint templates were developed based on the analyses of dose-volume histograms (DVHs) of tumor targets and adjacent sensitive structures by clinically approved treatment plans of 9 T1-2 and 16 T3-4 NPC patients treated with inverse planned intensity-modulated radiation therapy (IP-IMRT). DVHs; of sensitive structures were analyzed by examining multiple defined endpoints, based on the characteristics of each sensitive structure. For each subgroup of patients with T1-2 and T3-4 NPC, the resulting mean values of these defined endpoint doses were considered as templates for planning dose constraints and subsequently applied to a second group of patients, 5 with T1-2 NPC and 5 with T3-4 NPC. The 10 regenerated plans (called new plans) were compared to the original clinical plans that were used to treat the second group of patients, based on plan conformity index and DVHs. Results: The conformity indices of the new plans were comparable to the original plans with no statistical difference (p = 0.85). Among the serial sensitive structures evaluated, there was a significant decrease with the new plans in the dose to the spinal cord when analyzed by the maximum dose (p = 0.001), doses encompassing 1 cc of the spinal cord volume (p = 0.001) and 3 cc of the spinal cord volume (p = 0.001). There was no significant difference in the mean maximum dose to the brainstem between the new plans and the original plans (p = 0.36). However, a significant difference in the mean maximum dose to the brainstem was seen among the different T-stages (p = 0.04). A decrease with the new plan to the brainstem in the doses encompassing 5% and 10% of the volume was of borderline statistical significance (p = 0.08 and p = 0.06, respectively). There were no statistical differences between the new plans and the original plans in the mean doses to the chiasm, optic nerve, or eye for each of the endpoints considered. For parallel sensitive structures in the new plans, there was a significant increase in the average mean dose to the parotid glands (p = 0.01), a decrease that was of borderline significance in the average mean dose to the temporomandibular joint (p = 0.07), but no difference in the average mean dose to the ear. Conclusions: The statistical analysis showed that new plans are comparable to the original plans for most of the sensitive structures except for a trade-off between a dose reduction to the spinal cord in the new plans and an increase in the mean dose to the parotid glands. These tested planning dose constraint templates can serve as good "starting points" for an inverse plan of NPC using a specific commercial inverse treatment planning system. (C) 2004 Elsevier Inc.
引用
收藏
页码:886 / 896
页数:11
相关论文
共 50 条
  • [31] Comparative analysis of intensity modulation inverse planning modules of three commercial treatment planning systems
    Fogliato, A
    Bolsi, A
    Cozzi, L
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 120 - 120
  • [32] Efficient Outcomes-Driven IMRT Treatment Planning Using Commercial Treatment Planning Systems
    Li, X.
    Deasy, J.
    Mayo, C.
    Alber, M.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3334 - 3335
  • [33] Errors in inverse treatment planning based on inaccurate dose calculation
    Jeraj, R
    Keall, P
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 548 - 550
  • [34] A FILTERED BACKPROJECTION DOSE CALCULATION METHOD FOR INVERSE TREATMENT PLANNING
    HOLMES, T
    MACKIE, TR
    [J]. MEDICAL PHYSICS, 1994, 21 (02) : 303 - 313
  • [35] A convex optimization approach to radiation treatment planning with dose constraints
    Fu, Anqi
    Ungun, Baris
    Xing, Lei
    Boyd, Stephen
    [J]. OPTIMIZATION AND ENGINEERING, 2019, 20 (01) : 277 - 300
  • [36] A convex optimization approach to radiation treatment planning with dose constraints
    Anqi Fu
    Barıṣ Ungun
    Lei Xing
    Stephen Boyd
    [J]. Optimization and Engineering, 2019, 20 : 277 - 300
  • [37] Automation of prostate treatment planning with template dose mimicking constraints
    Vauclin, R.
    Prunaretty, J.
    Bus, N.
    Mengin, E.
    Silva, R. Marini
    Kallala, H.
    Paragios, N.
    Fenoglietto, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S825 - S826
  • [38] Dose-Volume Constraints for Particle Therapy Treatment Planning
    Stewart, R.
    Smith, W.
    Hendrickson, K.
    Meyer, J.
    Cao, N.
    Lee, E.
    Gopan, O.
    Sandison, G.
    Parvathaneni, U.
    Laramore, G.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3491 - 3491
  • [39] Testing of an enhanced leaf model for improved dose calculation in a commercial treatment planning system
    Van Esch, Ann
    Kulmala, Antti
    Rochford, Ronan
    Kauppinen, Juha
    Harju, Ari
    [J]. MEDICAL PHYSICS, 2022, 49 (12) : 7754 - 7765
  • [40] Evaluation of a Pencil Beam Scanning Proton Dose Model for a Commercial Treatment Planning System
    Patel, D.
    Poenisch, F.
    Sahoo, N.
    Zhu, X.
    Gillin, M.
    Janson, M.
    Mohan, R.
    Titt, U.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E261 - E261