On the alignment of transmission electron microscope images without fiducial markers

被引:0
|
作者
Brandt, S [1 ]
Heikkonen, J [1 ]
Engelhardt, P [1 ]
机构
[1] Helsinki Univ Technol, Lab Computat Engn, FIN-02015 Helsinki, Finland
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Accurate image alignment is needed for computing three-dimensional reconstructions from transmission electron microscope tilt series. So far, the best alignment results have been obtained by using colloidal gold beads as fiducial markers. If their use has not been possible for some reason, the only option has been the automatic 2D-cross-correlation-based registration methods. However, since the actual motion is three dimensional this approach is inaccurate and inappropriate for the whole problem. Conversely, we propose a novel method that uses the actual 3D motion model without any fiducial markers in the images. The method is based on matching and tracking corner features by first solving the underlying geometrical constraint of consecutive images in the tilt series. The results show that our method is competitive with the gold marker alignment in the level of accuracy and hence opens the way for new opportunities in the analysis of electron tomography reconstructions.
引用
下载
收藏
页码:278 / 281
页数:4
相关论文
共 50 条
  • [41] EFFECTIVENESS OF USING FEWER IMPLANTED FIDUCIAL MARKERS FOR PROSTATE TARGET ALIGNMENT
    Kudchadker, Rajat J.
    Lee, Andrew K.
    Yu, Zhiqian H.
    Johnson, Jennifer L.
    Zhang, Lifei
    Zhang, Yongbin
    Amos, Richard A.
    Nakanishi, Hiroyuki
    Ochiai, Atsushi
    Dong, Lei
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (04): : 1283 - 1289
  • [42] NATURE OF DEFOCUS FRINGES IN SCANNING-TRANSMISSION ELECTRON-MICROSCOPE IMAGES
    JOY, DC
    MAHER, DM
    CULLIS, AG
    JOURNAL OF MICROSCOPY-OXFORD, 1976, 108 (NOV): : 185 - 193
  • [43] The effectiveness of using fewer implanted fiducial markers for prostate target alignment
    Yu, Z. H.
    Kudchadker, R.
    Zhang, L.
    Johnson, J.
    Zhang, Y.
    Amos, R.
    Nakanishi, H.
    Ochiai, A.
    Dong, L.
    Lee, A. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S629 - S630
  • [44] ARTIFACTS IN TRANSMISSION ELECTRON-MICROSCOPE IMAGES OF ARTIFICIALLY LAYERED METALLIC SUPERLATTICES
    BAXTER, CS
    STOBBS, WM
    APPLIED PHYSICS LETTERS, 1986, 48 (18) : 1202 - 1204
  • [45] ELECTRON MICROSCOPE TRANSMISSION IMAGES OF COHERENT DOMAIN BOUNDARIES .2. OBSERVATIONS
    GEVERS, R
    DELAVIGNETTE, P
    BLANK, H
    VANLANDUYT, J
    AMELINCKX, S
    PHYSICA STATUS SOLIDI, 1964, 5 (03): : 595 - 633
  • [46] Determination of crystal polarity from bend contours in transmission electron microscope images
    Spiecker, E
    ULTRAMICROSCOPY, 2002, 92 (3-4) : 111 - 132
  • [47] Shape effect of microtwins on high-resolution transmission electron microscope images
    Kuramochi, K.
    Yamazaki, T.
    Nakanishi, N.
    Hashimoto, I.
    Watanabe, K.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2008, 205 (07): : 1602 - 1605
  • [48] A SYSTEM TO ACQUIRE AND PROCESS SCANNING-TRANSMISSION ELECTRON-MICROSCOPE IMAGES
    NYSSEN, M
    CORNELIS, A
    MAES, L
    DEZANGER, R
    ULTRAMICROSCOPY, 1982, 8 (04) : 429 - 436
  • [49] Enhancement of RGB-D Image Alignment Using Fiducial Markers
    Madeira, Tiago
    Oliveira, Miguel
    Dias, Paulo
    SENSORS, 2020, 20 (05)
  • [50] CONTRAST IN ELECTRON MICROSCOPE IMAGES
    KOMODA, T
    JOURNAL OF ELECTRON MICROSCOPY, 1957, 6 (1-2): : 10 - 12