A Novel Nanomodified Cellulose Insulation Paper for Power Transformer

被引:18
|
作者
Yuan, Yuan [1 ,2 ]
Liao, Ruijin [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Sch Mat Sci & Engn, Chongqing 400044, Peoples R China
关键词
MICROSTRUCTURE;
D O I
10.1155/2014/510864
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A novel cellulose insulation paper handsheet has successfully been modified with various contents of montmorillonite (MMT). Relative permittivity and breakdown strength were investigated. The microstructure of MMT in Kraft paper was observed with scanning electron microscopy (SEM) and X-ray diffraction. The relative permittivity of the immersed oil Kraft-MMT handsheets (K-MMT) initially decreased with the increasing amount of MMT. For MMT concentration of 9 wt%, K-9% MMT possessed the lowest relative permittivity of approximately 2.3 at 50 Hz. The breakdown voltage of the paper-oil-paper composite insulation system increased from 50.3 kV to 56.9 kV. The tensile strength of the paper handsheet was also measured.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Influence of Moisture Dispersion in Oil-paper Insulation on Dielectric Spectrum of Power Transformer
    Li, Jiajun
    Lv, Xiaolu
    Wang, Ke
    Li, Jinzhong
    Xia, Yuan
    Yang, Lijun
    Yang, Hao
    [J]. 2023 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, CEIDP, 2023,
  • [42] Assessment of power transformer insulation condition
    Sokolov, V
    Bulgakova, V
    Berler, Z
    [J]. ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 605 - 613
  • [43] TESTING METHODS FOR POWER TRANSFORMER INSULATION
    KAMATA, Y
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1986, 21 (06): : 1061 - 1063
  • [44] DRYING OF POWER-TRANSFORMER INSULATION
    ASEM, AS
    HOWE, AF
    [J]. IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1982, 129 (05) : 228 - 232
  • [45] Drying Transformer Cellulose Insulation by Means of Synthetic Ester
    Przybylek, P.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (04) : 2643 - 2648
  • [46] Condition Assessment of Oil-paper Insulation used in Power Transformer based on Polarization Energy
    Mukherjee, M.
    Pradhan, A. K.
    Baral, A.
    Chakravorti, S.
    [J]. 2015 International Conference on Condition Assessment Techniques in Electrical Systems (CATCON), 2015, : 222 - 225
  • [47] Investigation on Broadband Characteristics of Losses in Power Transformer Interturn Insulation Paper by Dielectric Relaxation Model
    Zheng, Yi-ming
    Wang, Zan-ji
    [J]. 2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 471 - 474
  • [48] A Mathematical Contribution to the Analysis of Moisture Migration in Power Transformer Oil-Paper Insulation Systems
    Marques, A. P.
    Sousa, F. R. de C.
    Brito, L. da C.
    Ribeiro, C. J.
    Azevedo, C. H. B.
    dos Santos, J. A. L.
    [J]. 2015 IEEE 10TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2015, : 1 - 6
  • [49] Conduction characteristics in transformer oil and electrical insulation paper
    Zhou, Yuanxiang
    Sha, Yanchao
    Chen, Weijiang
    Lu, Licheng
    Nie, Dexin
    Wu, Zhirong
    Deng, Jiangang
    [J]. Dianwang Jishu/Power System Technology, 2013, 37 (09): : 2527 - 2533
  • [50] Influence of Nonstandard Voltage Stresses on Transformer Insulation Paper
    Knenicky, Martin
    Prochazka, Radek
    Sefl, Ondrej
    [J]. 2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 700 - 703