Quantization of setup uncertainties in 3-D dose calculations

被引:44
|
作者
Lujan, AE [1 ]
Ten Haken, RK
Larsen, EW
Balter, JM
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
patient setup uncertainty; treatment verification; treatment planning; dose calculations;
D O I
10.1118/1.598756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Random setup errors can lead to erroneous prediction of the dose distribution calculated for a patient using a static computed tomography (CT) model. Multiple recomputations of the dose distribution covering the range of expected patient positions provides a way to estimate a course of treatment. However, due to the statistical nature of the setup uncertainties, many courses of treatment must be simulated to calculate a distribution of average dose values delivered to a patient. Thus, direct simulation methods can be time consuming and may be impractical for routine clinical treatment planning applications. Methods have been proposed to efficiently calculate the distribution of average dose values via a convolution of the dose distribution (calculated on a static CT model) with a probability distribution function (generally Gaussian) that describes the nature of the uncertainty. In this paper, we extend the convolution-based calculation to calculate the standard deviation of potential outcomes sigma(D)(x,y,z) about the distribution of average dose values, and we characterize the statistical significance of this quantity using the central limit theorem. For an example treatment plan based on a treatment protocol in use at our institution, we found that there is a 68% probability that the actual dose delivered to any point (x,y,z) will be within 3% of the average dose value at that point. The standard deviation also yields confidence limits on the dose distribution, and these may be used to evaluate treatment plan stability. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)02411-6].
引用
收藏
页码:2397 / 2402
页数:6
相关论文
共 50 条
  • [1] 3-D PION DOSE COMPARED WITH SINGLE SLICE CALCULATIONS
    ZINK, S
    BERARDO, PA
    PACIOTTI, MA
    BRADBURY, JN
    [J]. MEDICAL PHYSICS, 1981, 8 (04) : 568 - 568
  • [2] OFF-CENTER-RATIOS FOR 3-D DOSE CALCULATIONS
    CHUI, C
    MOHAN, R
    [J]. MEDICAL PHYSICS, 1985, 12 (04) : 507 - 507
  • [3] USE OF AN OCTREE-LIKE GEOMETRY FOR 3-D DOSE CALCULATIONS
    MCSHAN, DL
    FRAASS, BA
    [J]. MEDICAL PHYSICS, 1993, 20 (04) : 1219 - 1227
  • [4] 3-D CALCULATIONS OF NEUTRON DOSE FROM IMPLANTABLE CF-252 SOURCES
    WINDHAM, JP
    SHAPIRO, A
    KEREIAKE.JG
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1972, 15 (01): : 171 - &
  • [5] Length Estimation in 3-D Using Cube Quantization
    Amnon Jonas
    Nahum Kiryati
    [J]. Journal of Mathematical Imaging and Vision, 1998, 8 : 215 - 238
  • [6] Length estimation in 3-D using cube quantization
    Jonas, A
    Kiryati, N
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 1998, 8 (03) : 215 - 238
  • [7] A New Quantization Method for 3-D Seismic Visualization
    Hua Gang
    Lin Hai
    Sun Jinguang
    [J]. 2009 11TH IEEE INTERNATIONAL CONFERENCE ON COMPUTER-AIDED DESIGN AND COMPUTER GRAPHICS, PROCEEDINGS, 2009, : 457 - +
  • [8] Geological uncertainties associated with 3-D subsurface models
    Tacher, L
    Pomian-Srzednicki, I
    Parriaux, A
    [J]. COMPUTERS & GEOSCIENCES, 2006, 32 (02) : 212 - 221
  • [9] Uncertainties in internal dose calculations for radiopharmaceuticals
    Stabin, Michael G.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (05) : 853 - 860
  • [10] 3-D dose reconstruction in IORT
    Metzger, M
    Eble, MJ
    Hensley, FW
    [J]. INTRAOPERATIVE RADIATION THERAPY IN THE TREATMENT OF CANCER, 1997, 31 : 51 - 53