Production of harmonics in vitro by high-intensity focused ultrasound

被引:8
|
作者
Clarke, RL
ter Haar, GR
机构
[1] Ins Canc Res Royal Marsden NHS Trust, Joint Dept Phys, Royal Marsden Hosp, Sutton SM2 5PT, Surrey, England
[2] Carleton Univ, Ottawa, ON K1S 5B6, Canada
[3] Canc Res Inst, Ottawa, ON, Canada
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1999年 / 25卷 / 09期
关键词
focused ultrasound; in vitro; nonlinearity; harmonics; intensities; absorbed power; enhancement;
D O I
10.1016/S0301-5629(99)00088-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Experiments were performed to investigate the production of harmonics by high-intensity focused ultrasound (HIFU) produced by a spherical bowl; spherical radius 15 cm, frequency 1.7 MHz, as a function of beam power in excised bovine liver. The intensity of the nth harmonic, in both water and the tissue sample, varied approximately as the nth power of the incident intensity up to the point at which irreversible changes were produced in the sample, The greatest observed axial power absorption enhancement factor was approximately 6.3, and the greatest observed total absorbed power enhancement was approximately 2.3, These enhancements may have some effect on the onset of lesioning, but not much effect on its subsequent development. In water, at an intensity of about 120 W/cm(2) at the focus, the -3-dB beam diameters of harmonic components were observed to vary approximately as the inverse square root of the harmonic number. (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1417 / 1424
页数:8
相关论文
共 50 条
  • [1] In Vitro and In Vivo High-Intensity Focused Ultrasound Thrombolysis
    Wright, Cameron
    Hynynen, Kullervo
    Goertz, David
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (04) : 217 - 225
  • [2] PRODUCTION OF CORNEAL LESIONS USING HIGH-INTENSITY FOCUSED ULTRASOUND
    RUTZEN, AR
    ROBERTS, CW
    DRILLER, J
    GOMEZ, D
    LUCAS, BC
    LIZZI, FL
    COLEMAN, DJ
    [J]. CORNEA, 1990, 9 (04) : 324 - 330
  • [3] High-intensity focused ultrasound and cryotherapy
    Murat, F. J.
    [J]. CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2011, 78 : S11 - S11
  • [4] High-intensity focused ultrasound therapy
    Cheung, Vincent Y. T.
    [J]. BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2018, 46 : 74 - 83
  • [5] Pulsed high-intensity focused ultrasound enhances thrombolysis in an in vitro model
    Frenkel, V
    Oberoi, J
    Stone, MJ
    Park, M
    Deng, C
    Wood, BJ
    Neeman, Z
    Horne, M
    Li, KCP
    [J]. RADIOLOGY, 2006, 239 (01) : 86 - 93
  • [6] High-intensity focused ultrasound ablation: an in vitro agarose gel model
    Yang, Sen
    Chen, Yi-Jing
    Cui, Ran
    Zhao, Hua-Xin
    Zhao, Yu
    Liu, Zhu-Qing
    Yu, Yi
    Shao, Xiao-Yan
    Xu, Qing
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (11): : 15302 - 15308
  • [7] In vitro ablation of cardiac valves using high-intensity focused ultrasound
    Otsuka, R
    Fujikura, K
    Hirata, K
    Pulerwitz, T
    Oe, Y
    Suzuki, T
    Sciacca, R
    Marboe, C
    Wang, J
    Burkhoff, D
    Muratore, R
    Lizzi, FL
    Homma, S
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01): : 109 - 114
  • [8] Laser enhanced high-intensity focused ultrasound thrombolysis: An in vitro study
    Cui, Huizhong
    Yang, Xinmai
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (02): : EL123 - EL128
  • [9] In Vitro Atrial Septal Ablation Using High-Intensity Focused Ultrasound
    Takei, Yasuyoshi
    Muratore, Robert
    Kalisz, Andrew
    Okajima, Kazue
    Fujimoto, Kohei
    Hasegawa, Takuya
    Arai, Kotaro
    Rekhtman, Yelena
    Berry, Grace
    Di Tullio, Marco R.
    Homma, Shunichi
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (04) : 467 - 472
  • [10] TREATMENT OF GLAUCOMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    VALTOT, F
    KOPEL, J
    HAUT, J
    [J]. INTERNATIONAL OPHTHALMOLOGY, 1989, 13 (1-2) : 167 - 170