Non-invasive imaging of myocardial bridge by coronary computed tomography angiography: the value of transluminal attenuation gradient to predict significant dynamic compression

被引:15
|
作者
Li, Yuehua [1 ]
Yu, Mengmeng [1 ]
Zhang, Jiayin [1 ]
Li, Minghua [1 ]
Lu, Zhigang [2 ]
Wei, Meng [2 ]
机构
[1] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Inst Diagnost & Intervent Radiol, 600 Yishan Rd, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Cardiol, Affiliated Peoples Hosp 6, 600 Yishan Rd, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Coronary artery disease; Computed tomography; Myocardial bridge; Coronary angiography; Transluminal attenuation gradient; FRACTIONAL FLOW RESERVE; SYSTOLIC COMPRESSION; ARTERY STENOSIS; CT; OPACIFICATION; STRATEGIES; INFARCTION; STRESS; DEATH;
D O I
10.1007/s00330-016-4544-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To study the diagnostic value of transluminal attenuation gradient (TAG) measured by coronary computed tomography angiography (CCTA) for identifying relevant dynamic compression of myocardial bridge (MB). Patients with confirmed MB who underwent both CCTA and ICA within one month were retrospectively included. TAG was defined as the linear regression coefficient between luminal attenuation and distance. The TAG of MB vessel, length and depth of MB were measured and correlated with the presence and degree of dynamic compression observed at ICA. Systolic compression ae 50 % was considered significant. 302 patients with confirmed MB lesions were included. TAG was lowest (-17.4 +/- 6.7 HU/10 mm) in patients with significant dynamic compression and highest in patients without MB compression (-9.5 +/- 4.3 HU/10 mm, p < 0.001). Linear correlation revealed relation between the percentage of systolic compression and TAG (Pearson correlation, r = -0.52, p < 0.001) and no significant relation between the percentage of systolic compression and MB depth or length. ROC curve analysis determined the best cut-off value of TAG as -14.8HU/10 mm (area under curve = 0.813, 95 % confidence interval = 0.764-0.855, p < 0.001), which yielded high diagnostic accuracy (82.1 %, 248/302). The degree of ICA-assessed systolic compression of MB significantly correlates with TAG but not MB depth or length. aEuro cent TAG is associated with the extent of dynamic compression of MB. aEuro cent TAG is superior to depth and length for identifying dynamic compression. aEuro cent Cut-off value of TAG as -14.8HU/10 mm yielded high predictive value.
引用
收藏
页码:1971 / 1979
页数:9
相关论文
共 50 条
  • [31] Additional Value of Transluminal Attenuation Gradient in CT Angiography to Predict Hemodynamic Significance of Coronary Artery Stenosis
    Stuijfzand, Wynand J.
    Danad, Ibrahim
    Raijmakers, Pieter G.
    Marcu, C. Bogdan
    Heymans, Martijn W.
    van Kuijk, Cornelis C.
    van Rossum, Albert C.
    Nieman, Koen
    Min, James K.
    Leipsic, Jonathon
    van Royen, Niels
    Knaapen, Paul
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (04) : 374 - 386
  • [32] Comparison of invasive and non-invasive coronary angiography with multislice computed tomography in clinical routine
    BÖhme, GE
    Steinbigler, P
    Czernik, A
    Luber, A
    Buck, J
    Haberi, R
    EUROPEAN HEART JOURNAL, 2003, 24 : 570 - 570
  • [33] Non-invasive physiological assessment of coronary artery obstruction on coronary computed tomography angiography
    Becker, Leonie M.
    Peper, Joyce
    van Nes, Sophie H.
    van Es, Hendrik W.
    Sjauw, Krischan D.
    van de Hoef, Tim P.
    Leiner, Tim
    Swaans, Martin J.
    NETHERLANDS HEART JOURNAL, 2024, 32 (11) : 397 - 404
  • [34] ACCURACY OF NON-INVASIVE MULTISLICE COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY; DETECTION OF SIGNIFICANT STENOSIS VERSUS DETECTION OF ATHEROSCLEROSIS
    Velzen, Joella E.
    Schuijf, Joanne D.
    De Graaf, Fleur R.
    Pundziute, Gabija
    Spano, Fabrizio
    Van Werkhoven, Jacob M.
    Schalij, Martin J.
    Kroft, Lucia J.
    De Roos, Albert
    Reiber, Johannes H.
    Jukema, J. Wouter
    Van der Wall, Ernst E.
    Bax, Jeroen J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [35] Diagnostic accuracy of non-invasive coronary angiography with 320-slice dynamic volume computed tomography
    Nasis, A.
    Leung, M. C.
    Antonis, P. R.
    Cameron, J. D.
    Meredith, I. T.
    Moir, W. S.
    Hope, S. A.
    Troupis, J. M.
    Crossett, M. P.
    Seneviratne, S. K.
    EUROPEAN HEART JOURNAL, 2009, 30 : 181 - 181
  • [36] Transluminal Attenuation Gradient in Coronary Computed Tomography Angiography Is a Novel Noninvasive Approach to the Identification of Functionally Significant Coronary Artery Stenosis A Comparison With Fractional Flow Reserve
    Wong, Dennis T. L.
    Ko, Brian S.
    Cameron, James D.
    Nerlekar, Nitesh
    Leung, Michael C. H.
    Malaiapan, Yuvaraj
    Crossett, Marcus
    Leong, Darryl P.
    Worthley, Stephen G.
    Troupis, John
    Meredith, Ian T.
    Seneviratne, Sujith K.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (12) : 1271 - 1279
  • [37] Non-invasive Coronary Physiologic Study Based on Computational Analysis of Intracoronary Transluminal Attenuation Gradient
    Choi, Jin Ho
    Park, Il
    Lee, Joo Myung
    Kim, Hyung Yoon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S44 - S44
  • [38] Non-invasive coronary angiography with multislice computed tomography: A comparison with conventional angiography in 62 patients
    Nieman, K
    Rensing, BJ
    Munne, A
    Pattynama, PM
    De Feyter, PJ
    CIRCULATION, 2001, 104 (17) : 614 - 614
  • [39] Data for comparison of computed tomography angiography and dynamic myocardial perfusion to detect significant stenosis by coronary angiography
    Tomizawa, Nobuo
    Chou, Shengpu
    Fujino, Yusuke
    Kamitani, Masaru
    Yamamoto, Kodai
    Inoh, Shinichi
    Nojo, Takeshi
    Kumamaru, Kanako K.
    Aoki, Shigeki
    Nakamura, Sunao
    DATA IN BRIEF, 2018, 21 : 953 - 955
  • [40] Non-invasive coronary artery imaging using multislice computed tomography
    Paul, JF
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2005, 189 (04): : 657 - 670