Design and implementation of an electromagnetic ultrasound-based navigation technique for laparoscopic ablation of liver tumors

被引:11
|
作者
Paolucci, Iwan [1 ]
Schwalbe, Marius [1 ]
Prevost, Gian Andrea [2 ]
Lachenmayer, Anja [2 ]
Candinas, Daniel [2 ]
Weber, Stefan [1 ]
Tinguely, Pascale [2 ]
机构
[1] Univ Bern, ARTORG Ctr Biomed Engn Res, Bern, Switzerland
[2] Univ Bern, Univ Hosp Bern, Dept Visceral Surg & Med, Inselspital, Bern, Switzerland
基金
欧盟地平线“2020”;
关键词
Ablation techniques; Computer-assisted surgery; Laparoscopy; Ultrasonography; Three-dimensional imaging; Liver neoplasms; RADIOFREQUENCY ABLATION; CLINICAL-APPLICATIONS; ENHANCED-ULTRASOUND; MICROWAVE ABLATION; IMAGE GUIDANCE; SURGERY; SYSTEM; METASTASES; RECONSTRUCTION; PROTOTYPE;
D O I
10.1007/s00464-018-6088-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Efficient laparoscopic ablation of liver tumors relies on precise tumor visualization and accurate positioning of ablation probes. This study evaluates positional accuracy and procedural efficiency of a dynamic navigation technique based on electromagnetic-tracked laparoscopic ultrasound (ELUS) for laparoscopic ablation of liver tumors. The proposed navigation approach combines intraoperative 2D ELUS-based planning for navigated positioning of ablation probes, with immediate 3D ELUS-based validation of intrahepatic probe position. The environmental influence on electromagnetic-tracking stability was evaluated in the operation room. Accuracy of navigated ablation probe positioning assessed as the target-positioning error (TPE), and procedural efficiency defined as time efforts for target definition/navigated targeting and number of probe repositionings, were evaluated in a laparoscopic model and compared with conventional laparoscopic ultrasound (LUS) guidance. The operation-room environment showed interferences < 1 mm on the EM-tracking system. A total of 60 targeting attempts were conducted by three surgeons, with ten targeting attempts using ELUS and ten using conventional LUS each. Median TPE and time for targeting using ELUS and LUS were 4.2 mm (IQR 2.9-5.3 mm) versus 6 mm (IQR 4.7-7.5 mm), and 39 s (IQR 24-47 s) versus 76 s (IQR 47-121 s), respectively (p < 0.01 each). With ELUS, median time for target definition was 48.5 s, with 0 ablation probe repositionings compared to 17 when using LUS. The navigation technique was rated with a mean score of 85.5 on a Standard Usability Scale. The proposed ELUS-based navigation approach allows for accurate and efficient targeting of liver tumors in a laparoscopic model. Focusing on a dynamic and tumor-targeted navigation technique relying on intraoperative imaging, this avoids potential inaccuracies due to organ deformation and yields a user-friendly technique for efficient laparoscopic ablation of liver tumors.
引用
收藏
页码:3410 / 3419
页数:10
相关论文
共 50 条
  • [21] Innovative ultrasound-based diagnosis of renal tumors
    Stock, K. F.
    Slotta-Huspenina, J.
    Kuebler, H.
    Autenrieth, M.
    UROLOGE, 2019, 58 (12): : 1418 - 1428
  • [22] A test environment for ultrasound-based navigation in radiation therapy
    Riesner, S
    Golias, D
    Schweikard, A
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 112 - 117
  • [23] Ultrasound-based triggered drug delivery to tumors
    Ankit Jain
    Ankita Tiwari
    Amit Verma
    Sanjay K. Jain
    Drug Delivery and Translational Research, 2018, 8 : 150 - 164
  • [24] Validation platform for ultrasound-based monitoring of thermal ablation
    Pompeu-Robinson, Alexandra M.
    Gray, James
    Marble, Joshua
    Peikari, Hamed
    Hall, Jena
    U-Thainual, Paweena
    Aboofazeli, Mohammad
    Lasso, Andras
    Fichtinger, Gabor
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [25] Electromagnetic Navigation to Aid Radiofrequency Ablation and Biopsy of Lung Tumors
    Santos, Ricardo S.
    Gupta, Avneesh
    Ebright, Michael I.
    DeSimone, Michael
    Steiner, Gregory
    Estrada, Mary-Jane
    Daly, Benedict
    Fernando, Hiran C.
    ANNALS OF THORACIC SURGERY, 2010, 89 (01): : 265 - 268
  • [26] Ultrasound-based techniques for the diagnosis of liver steatosis
    Ferraioli, Giovanna
    Soares Monteiro, Livia Beatriz
    WORLD JOURNAL OF GASTROENTEROLOGY, 2019, 25 (40) : 6053 - 6062
  • [27] Ultrasound-based liver elastography in the assessment of fibrosis
    Fang, C.
    Lim, A.
    Sidhu, P. S.
    CLINICAL RADIOLOGY, 2020, 75 (11) : 822 - 831
  • [28] Comparison Between Pointer-based and Ultrasound-based Navigation Technique in THA Using a Minimally Invasive Approach
    Hasart, Olaf
    Perka, Carsten
    Tohtz, Stephan
    ORTHOPEDICS, 2008, 31 (10) : 31 - 34
  • [29] Ultrasound-based techniques for the diagnosis of liver steatosis
    Giovanna Ferraioli
    Livia Beatriz Soares Monteiro
    World Journal of Gastroenterology, 2019, (40) : 6053 - 6062
  • [30] Ultrasound-based navigation of robotic drilling at the lateral skull base
    Federspil, PA
    Tretbar, SH
    Geisthoff, U
    Plinkert, B
    Plinkert, PK
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1358 - 1358