Fabrication and Analysis of a Ti6Al4V Implant for Cranial Restoration

被引:21
|
作者
Moiduddin, Khaja [1 ]
Mian, Syed Hammad [1 ]
Umer, Usama [1 ]
Alkhalefah, Hisham [1 ]
机构
[1] King Saud Univ, Adv Mfg Inst, Riyadh 11421, Saudi Arabia
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 12期
关键词
cranial restoration; electron beam melting; custom-made implant; 3D comparison; tensile strength; mirror reconstruction; rockwell hardness; MECHANICAL-PROPERTIES; RECONSTRUCTION; OUTCOMES; DESIGN; PLATES;
D O I
10.3390/app9122513
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A custom made implant is critical in cranioplasty to cushion and restore intracranial anatomy, as well as to recover the appearance and attain cognitive stability in the patient. The utilization of customized titanium alloy implants using three-dimensional (3D) reconstruction technique and fabricated using Electron Beam Melting (EBM) has gained significant recognition in recent years, owing to their convenience and effectiveness. Besides, the conventional technique or the extant practice of transforming the standard plates is unreliable, arduous and tedious. As a result, this work aims to produce a customized cranial implant using 3D reconstruction that is reliable in terms of fitting accuracy, appearance, mechanical strength, and consistent material composition. A well-defined methodology initiating from EBM fabrication to final validation has been outlined in this work. The custom design of the implant was carried out by mirror reconstruction of the skull's defective region, acquired through computer tomography. The design of the customized implant was then analyzed for mechanical stresses by applying finite element analysis. Consequently, the 3D model of the implant was fabricated from Ti6Al4V ELI powder with a thickness of similar or equal to 1.76-2 mm. Different tests were employed to evaluate the bio-mechanical stability and strength of the fabricated customized implant design. A 3D comparison study was performed to ensure there was anatomical accuracy, as well as to maintain gratifying aesthetics. The bio-mechanical analysis results revealed that the maximum Von Mises stress (2.5 MPa), strain distribution (1.49 x 10(-4)) and deformation (3.26 x 10(-6) mm) were significantly low in magnitude, thus proving the implant load resistance ability. The average yield and tensile strengths for the fabricated Ti6Al4V ELI EBM specimen were found to be 825 MPa and 880 MPa, respectively, which were well over the prescribed strength for Ti6Al4V ELI implant material. The hardness study also resulted in an acceptable outcome within the acceptable range of 30-35 HRC. Certainly, the chemical composition of the fabricated EBM specimen was intact as established in EDX analysis. The weight of the cranial implant (128 grams) was also in agreement with substituted defected bone portion, ruling out any stress shielding effect. With the proposed approach, the anatomy of the cranium deformities can be retrieved effectively and efficiently. The implementation of 3D reconstruction techniques can conveniently reduce tedious alterations in the implant design and subsequent errors. It can be a valuable and reliable approach to enhance implant fitting, stability, and strength.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Fabrication of porous Ti6Al4V with designed structure by rapid prototyping technology
    Li, J. P.
    Wilson, C.
    Wijn, J. R.
    Van Blitterswijk, C. A.
    De Groot, K.
    BIOCERAMICS, VOL 19, PTS 1 AND 2, 2007, 330-332 : 1293 - +
  • [32] Surface characteristics comparison between additively manufactured Ti6Al4V and wrought Ti6Al4V turned samples
    Saffioti, Maria Rosaria
    Rotella, Giovanna
    Del Prete, Antonio
    MATERIAL FORMING, ESAFORM 2024, 2024, 41 : 2050 - 2056
  • [33] The mechanical behavior of the Ti6Al4V/Ti/Ti6Al4V composite produced by directed energy deposition under impact loading
    Kuzminova, Yulia O.
    Dubinin, Oleg N.
    Gushchina, Marina O.
    Simonov, Alexey P.
    Konev, Stepan D.
    Sarkeeva, Aigul A.
    Zhilyaev, Alexander P.
    Evlashin, Stanislav A.
    MATERIALIA, 2023, 27
  • [34] SURFACE MODIFICATIONS OF A Ti6AL4V IMPLANT/ALLOY BY A PICOSECOND Nd:YAG LASER
    Trtica, M. S.
    Gakovic, B.
    Radak, B.
    Maravic, D.
    Batani, D.
    Desai, T.
    24TH SUMMER SCHOOL AND INTERNATIONAL SYMPOSIUM ON THE PHYSICS OF IONIZED GASES, CONTRIBUTED PAPERS, 2008, (84): : 227 - +
  • [35] Short-Term Heat Treatment of Ti6Al4V ELI as Implant Material
    Phuong Thao Mai
    Bormann, Therese
    Sonntag, Robert
    Kretzer, Jan Philippe
    Gibmeier, Jens
    MATERIALS, 2020, 13 (21) : 1 - 14
  • [36] Abrasive machining of Ti6Al4V alloy
    Lattner, Radek
    Holešovskỳ, František
    Karel, Tomáš
    Lattner, Michal
    Manufacturing Technology, 2015, 15 (04): : 571 - 575
  • [37] Mechanical stability of Ti6Al4V implant material after femtosecond laser irradiation
    Symietz, Christian
    Lehmann, Erhard
    Gildenhaar, Renate
    Hackbarth, Andreas
    Berger, Georg
    Krueger, Joerg
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (02)
  • [38] Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: Trabecular titanium
    Marin, E.
    Fusi, S.
    Pressacco, M.
    Paussa, L.
    Fearizzi, L.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2010, 3 (05) : 373 - 381
  • [39] Behaviour of Ti6Al4V implant alloy in vitro after plastic deformation by bending
    Kierzkowska, Agnieszka
    Krasicka-Cydzik, Elzbieta
    SURFACE AND INTERFACE ANALYSIS, 2008, 40 (3-4) : 507 - 512
  • [40] Thermal cycling In (α+β) Ti6Al4V alloy
    M. N. Mungole
    Rahul Kanojiya
    Rakesh Sharma
    Bijayani Panda
    Transactions of the Indian Institute of Metals, 2008, 61 : 93 - 97