Rapid deflation of the bronchial cuff of the double-lumen tube after decreasing the concentration of inspired nitrous oxide

被引:3
|
作者
Karasawa, F [1 ]
Takita, A [1 ]
Takamatsu, I [1 ]
Mori, T [1 ]
Oshima, T [1 ]
Kawatani, Y [1 ]
机构
[1] Natl Def Med Coll, Dept Anesthesiol, Tokorozawa, Saitama 3598513, Japan
来源
ANESTHESIA AND ANALGESIA | 2002年 / 95卷 / 01期
关键词
D O I
10.1097/00000539-200207000-00044
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Deflationary phenomena of the endotracheal tube cuff may occux after inspired nitrous oxide (NO) concentrations are reduced, but deflationary phenomena of the double-lumen tube (DLT) cuff have not been investigated. In this study, tracheal and bronchial cuffs of left-sided Mallinckrodt (Athlone, Ireland) DLTs were inflated with air, 40% N2O, or 67% N2O (Air, N40, or N67 groups, respectively) in 24 patients undergoing thoracic surgery; 40 min later, O-2 was substituted for N2O in some of the patients in the N40 group (N40-c group). Intracuff gas volumes, N2O concentrations, and cuff compliance were also measured. Both tracheal and bronchial cuff pressures significantly increased in the Air group but decreased in the N67 group. Neither pressure significantly changed in the N40 group, but both decreased in the N40-c group after terminating N2O anesthesia; the time required for bronchial cuff pressures to decrease by half (12.0 +/- 5.5 min) was less than that for tracheal cuff pressures (31.2 +/- 11.0 min, P < 0.01). The volume change in the N40-c group was not significantly different between the tracheal and bronchial cuffs, but tracheal cuff compliance was significantly higher than bronchial compliance. Therefore, filling DLT cuffs with 40% N2O stabilizes cuff pressure during anesthesia with 67% N2O, but bronchial cuffs deflate more quickly than tracheal cuffs after cessation of N2O administration through smaller compliance.
引用
收藏
页码:238 / 242
页数:5
相关论文
共 50 条
  • [41] Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size
    Seo, Jeong-Hwa
    Bae, Jinyoung
    Paik, Hyesun
    Koo, Chang-Hoon
    Bahk, Jae-Hyon
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (02) : 863 - 868
  • [42] Comparison of double-lumen tube and bronchial blocker on one-lung ventilation for thoracoscopy
    Bauer, C
    Esclope, C
    Hentz, JG
    Ducrocq, X
    Steib, A
    Dupeyron, JP
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 : 26 - 26
  • [43] The use of a bronchial blocker to rescue an ill-fitting double-lumen endotracheal tube
    Nino, M
    Body, SC
    Hartigan, PM
    ANESTHESIA AND ANALGESIA, 2000, 91 (06): : 1370 - 1371
  • [44] TRACHEO-BRONCHIAL BALLOON-BLOCKING - AN ALTERNATIVE METHOD TO DOUBLE-LUMEN TUBE
    KLEPP, G
    FRIEHS, G
    PINTER, H
    FILZWIESER, G
    ACTA CHIRURGICA AUSTRIACA, 1983, 15 (04): : 85 - 86
  • [45] Fluoroscopy, a useful alternative for confirming accurate placement of double-lumen tube or bronchial blocker
    Date, Aparna
    Wagh, Harshal D.
    Shah, Milin
    SAUDI JOURNAL OF ANAESTHESIA, 2021, 15 (04) : 473 - 474
  • [46] Unplanned impossible tracheal intubation with double-lumen tube: a case of bronchial blocker creation
    Righetti, Roberto
    Zani, Gianluca
    Diamanti, Marina
    Scaramuzza, Aliza
    Papetti, Matilde
    Graziani, Elia
    Terenzoni, Massimo
    Baccarini, Federico Domenico
    Fusari, Maurizio
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [47] USE OF A DOUBLE-LUMEN TRACHEOSTOMY TUBE AFTER SINGLE LUNG TRANSPLANTATION
    HARWOOD, RJ
    GRAHAM, TR
    KENDALL, SW
    ODURO, A
    WELLS, FC
    WALLWORK, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 103 (06): : 1224 - 1226
  • [48] Intraoperative management of tracheobronchial rupture after double-lumen tube intubation
    Ceylan, Kenan Can
    Kaya, Seyda Ors
    Samancilar, Ozgur
    Usluer, Ozan
    Gursoy, Soner
    Ucvet, Ahmet
    SURGERY TODAY, 2013, 43 (07) : 757 - 762
  • [49] Intraoperative management of tracheobronchial rupture after double-lumen tube intubation
    Kenan Can Ceylan
    Seyda Ors Kaya
    Ozgur Samancilar
    Ozan Usluer
    Soner Gursoy
    Ahmet Ucvet
    Surgery Today, 2013, 43 : 757 - 762
  • [50] Endotracheal tube cuff leakage after termination of nitrous oxide
    Nomura, T
    Asano, M
    Shibata, M
    Ishi, M
    ANESTHESIOLOGY, 1999, 91 (3A) : U277 - U277