Rapid deflation of the bronchial cuff of the double-lumen tube after decreasing the concentration of inspired nitrous oxide

被引:3
|
作者
Karasawa, F [1 ]
Takita, A [1 ]
Takamatsu, I [1 ]
Mori, T [1 ]
Oshima, T [1 ]
Kawatani, Y [1 ]
机构
[1] Natl Def Med Coll, Dept Anesthesiol, Tokorozawa, Saitama 3598513, Japan
来源
ANESTHESIA AND ANALGESIA | 2002年 / 95卷 / 01期
关键词
D O I
10.1097/00000539-200207000-00044
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Deflationary phenomena of the endotracheal tube cuff may occux after inspired nitrous oxide (NO) concentrations are reduced, but deflationary phenomena of the double-lumen tube (DLT) cuff have not been investigated. In this study, tracheal and bronchial cuffs of left-sided Mallinckrodt (Athlone, Ireland) DLTs were inflated with air, 40% N2O, or 67% N2O (Air, N40, or N67 groups, respectively) in 24 patients undergoing thoracic surgery; 40 min later, O-2 was substituted for N2O in some of the patients in the N40 group (N40-c group). Intracuff gas volumes, N2O concentrations, and cuff compliance were also measured. Both tracheal and bronchial cuff pressures significantly increased in the Air group but decreased in the N67 group. Neither pressure significantly changed in the N40 group, but both decreased in the N40-c group after terminating N2O anesthesia; the time required for bronchial cuff pressures to decrease by half (12.0 +/- 5.5 min) was less than that for tracheal cuff pressures (31.2 +/- 11.0 min, P < 0.01). The volume change in the N40-c group was not significantly different between the tracheal and bronchial cuffs, but tracheal cuff compliance was significantly higher than bronchial compliance. Therefore, filling DLT cuffs with 40% N2O stabilizes cuff pressure during anesthesia with 67% N2O, but bronchial cuffs deflate more quickly than tracheal cuffs after cessation of N2O administration through smaller compliance.
引用
收藏
页码:238 / 242
页数:5
相关论文
共 50 条
  • [1] Failure of Double-Lumen Tube Cuff Deflation on the Cuff Leak Test
    Nakazawa, Koichi
    Ohtaha, Megumi
    Makita, Koshi
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (06) : 1025 - 1025
  • [2] BRONCHIAL CUFF PRESSURES OF DOUBLE-LUMEN TUBES
    BRODSKY, JB
    ADKINS, MO
    GABA, DM
    ANESTHESIA AND ANALGESIA, 1989, 69 (05): : 608 - 610
  • [3] BRONCHIAL CUFF PRESSURE OF ENDOBRONCHIAL DOUBLE-LUMEN TUBES
    NETO, PPR
    ANESTHESIA AND ANALGESIA, 1990, 71 (02): : 209 - 209
  • [4] Displacement of the double-lumen endobronchial tube can be detected by bronchial cuff pressure change
    Araki, K
    Nomura, R
    Urushibara, R
    Yoshikawa, Y
    Hatano, Y
    ANESTHESIA AND ANALGESIA, 1997, 84 (06): : 1349 - 1353
  • [5] Disconnection Technique With a Bronchial Blocker for Improving Lung Deflation: A Comparison With a Double-Lumen Tube and Bronchial Blocker Without Disconnection
    Yoo, Ji Young
    Kim, Dae Hee
    Choi, Ho
    Kim, Kun
    Chae, Yun Jeong
    Park, Sung Yong
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (04) : 904 - 907
  • [6] The margin of safety of a left double-lumen tracheobronchial tube depends on the length of the bronchial cuff and tip
    Partridge, L.
    Russell, W. J.
    ANAESTHESIA AND INTENSIVE CARE, 2006, 34 (05) : 618 - 620
  • [7] Double-lumen endobronchial tube cuff pressures: a need for monitoring?
    Daunt, M.
    Latter, J.
    ANAESTHESIA, 2013, 68 (10) : 1089 - 1089
  • [8] A simple method to protect the tracheal cuff of a double-lumen tube
    Coppa, GP
    Brodsky, JB
    ANESTHESIA AND ANALGESIA, 1998, 86 (03): : 675 - 675
  • [9] Bronchial cuff pressure change caused by left-sided double-lumen endobronchial tube displacement
    Kazukuni Araki
    Ryoichi Nomura
    Reiko Urushibara
    Yukiko Yoshikawa
    Yoshio Hatano
    Canadian Journal of Anesthesia, 2000, 47 : 775 - 779
  • [10] Bronchial cuff pressure change caused by left-sided double-lumen endobronchial tube displacement
    Araki, K
    Nomura, R
    Urushibara, R
    Yoshikawa, Y
    Hatano, Y
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2000, 47 (08): : 775 - 779