A simple model for automatically measuring radon exhalation rate from medium surface

被引:8
|
作者
Tan, Yanliang [1 ,2 ]
Xiao, Detao [2 ]
机构
[1] Hengyang Normal Univ, Dept Phys & Elect, Hengyang City 421008, Hunan, Peoples R China
[2] Univ South China, Sch Nucl Sci & Technol, Hengyang City 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Simple model; Radon exhalation rate; Sufficient condition;
D O I
10.1016/j.radmeas.2014.04.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A simple model to measure radon exhalation rate from medium surface is developed in this paper. This model is based on a combination of the "accumulation chamber" technique and a radon monitor. The radon monitor is used to perform measurement of radon concentration evolution inside the accumulation chamber, and radon exhalation rate is evaluated via nonlinear least-square fitting of the measured data. If the flow rate of the pump is high enough, radon concentration in the detector's internal cell becomes to be equal to that in the accumulation chamber quickly, and the simple model for measuring the radon exhalation rate can be generated analytically. Generally, the pump flow rate of radon monitor is low, not satisfying the condition. We find other sufficient conditions of this simplified model. On these conditions, the radon exhalation rate can be calculated accurately through this model even the flow rate of the pump is not so high. This method can be applied to develop and improve the instruments for measuring the radon exhalation rate. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 47
页数:4
相关论文
共 50 条
  • [31] A simple technique for studying the dependence of radon and thoron exhalation rate from building materials on absolute humidity
    Hassan, Nabil M.
    Tokonami, Shinji
    Fukushi, Masahiro
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (01) : 185 - 191
  • [32] Laboratory study on the relationship between the vertical distribution of radon concentration in soil and the exhalation rate of radon from the soil surface
    Wu, Jiulin
    Xie, Ruomei
    Yi, Haibo
    Hu, Tao
    Sun, Jiale
    Liu, Zhipeng
    Li, Huiying
    Liu, Shuaibin
    Yuan, Shuai
    Tan, Yanliang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (12) : 6149 - 6154
  • [33] A simple technique for studying the dependence of radon and thoron exhalation rate from building materials on absolute humidity
    Nabil M. Hassan
    Shinji Tokonami
    Masahiro Fukushi
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 287 : 185 - 191
  • [34] Feasibility for mapping radon exhalation rate from soil in China
    Sun, KN
    Guo, QJ
    Zhuo, WH
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2004, 41 (01) : 86 - 90
  • [35] Estimation of the radon surface exhalation rate from a wall as related to that from its building material sample
    Orabi, M.
    CANADIAN JOURNAL OF PHYSICS, 2018, 96 (03) : 353 - 357
  • [36] Open charcoal chamber method for mass measurements of radon exhalation rate from soil surface
    Tsapalov, Andrey
    Kovler, Konstantin
    Miklyaev, Peter
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 160 : 28 - 35
  • [37] EFFECT OF MOISTURE AND ADDITIVE ON RADON EXHALATION RATE FROM CONCRETE
    Kumar, Amit
    Chauhan, R. P.
    ROMANIAN JOURNAL OF PHYSICS, 2015, 60 (9-10): : 1589 - 1597
  • [38] RADON EXHALATION RATE FROM VARIOUS BUILDING-MATERIALS
    CHEN, CJ
    WENG, PS
    CHU, TC
    HEALTH PHYSICS, 1993, 64 (06): : 613 - 619
  • [39] Comparison of indoor radon level with radon exhalation rate from soil in Garhwal Himalaya
    Gusain, G. S.
    Prasad, Ganesh
    Prasad, Yogesh
    Ramola, R. C.
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 1032 - 1035
  • [40] Comparison of two models for measuring radon exhalation rate with a ventilation chamber by numerical simulation
    Lin, F.
    Xie, R.
    Fan, Z.
    Hu, T.
    Mo, Y.
    Liu, S.
    Yuan, S.
    Wang, L.
    Yuan, H.
    Tang, J.
    Tan, Y.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (10)