Monitoring and estimation of the kinetics parameters in the binding process of tannic acid to bovine serum albumin with electrochemical quartz crystal impedance system

被引:16
|
作者
Liu, Meiling [1 ]
Zhang, Youyu [1 ]
Yang, Qin [1 ]
Xie, Qingji [1 ]
Yao, Shouzhuo [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Chem Biol & Trad Chinese Med Res, Changsha 410081, Peoples R China
关键词
tannic acid; bovine serum albumin; piezoelectric quartz crystal impedance; electrochemical impedance; electrochemical piezoelectric quartz crystal impedance system; FT-IR;
D O I
10.1021/jf052489r
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Combined measurements of piezoelectric quartz crystal impedance (PQCI) and electrochemical impedance (EI) were utilized in situ to monitor the adsorption of bovine serum albumin (BSA) onto the newly prepared Au colloid- modified electrode and study the binding process of tannic acid (TA) to BSA on the BSA- modified electrode surface. The time courses of the resonant frequency and the equivalent parameters of the sensor were simultaneously obtained during BSA adsorption and TA-BSA binding. Compared with the bare gold electrode, the Au colloid- modified gold electrode showed better biocompatibility, and the absorption capacity for BSA was increased by similar to 2.4 times. The observed frequency decrease was ascribed to the mass increase of the sensor surface resulting from the TA-BSA binding, which is believed to result mainly from the hydrogen bonding from FT-IR characterization. The maximal molar binding ratio of TA binding to immobilized BSA obtained from the frequency shift of the adsorbed BSA and TA was estimated to be 10.3:1. On the basis of the frequency decrease with time, the kinetics of the binding was quantitatively studied. By way of fitting the experimental data, the kinetics parameters, that is, binding and dissociation constant (k(1), k(-1)), and the binding equilibrium constant (k(a)) were determined, giving values of 9.51 x 10(4) M-1 s(-1), 3.15 s(-1), and 3.1 x 10(4) M-1, respectively.
引用
收藏
页码:4087 / 4094
页数:8
相关论文
共 50 条
  • [41] POSITIVE COOPERATIVITY IN BINDING BY ALBUMIN - THE SYSTEM BOVINE SERUM-ALBUMIN AND ALIZARIN YELLOW-G COBINDING BY SALICYLIC-ACID
    NISSANI, E
    KOREN, R
    PERLMUTTERHAYMAN, B
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1983, 226 (01) : 357 - 364
  • [42] Au@bovine serum albumin nanoparticle-based acid-resistant nanozyme quartz crystal microbalance sensing of urine glucose
    Zhou, Dengfeng
    Song, Wenyao
    Zhang, Shuangbin
    Chen, Lan
    Ge, Guanglu
    RSC ADVANCES, 2022, 12 (46) : 29727 - 29733
  • [43] Quartz crystal microbalance study of bovine serum albumin adsorption onto self-assembled monolayer-functionalized gold with subsequent ligand binding
    Thourson, Scott B.
    Marsh, Caitlin A.
    Doyle, Brian J.
    Timpe, Shannon J.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 111 : 707 - 712
  • [44] In situ monitoring Ni electrodeposition and stripping on gold electrode surface in a static magnetic field using an electrochemical quartz crystal impedance system
    Zhang, Youyu
    Liu, Meiling
    Wang, Meiling
    Xie, Qingji
    Yao, Shouzhuo
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) : 444 - 453
  • [45] Newly developed real time monitoring system for ionic migration by means of quartz crystal microbalance (QCM)and electrochemical impedance spectroscopy(EIS).
    Yoshihara, S
    ADVANCES IN ELECTRONIC PACKAGING 2003, VOL 1, 2003, : 735 - 739
  • [46] COMPARISON OF THE QUARTZ-CRYSTAL MICROBALANCE AND THE DOUBLE-LAYER CAPACITANCE METHODS FOR MEASURING THE KINETICS OF THE ADSORPTION OF BOVINE SERUM-ALBUMIN ONTO A GOLD ELECTRODE
    LACOUR, F
    TORRESI, R
    GABRIELLI, C
    CAPRANI, A
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1992, 139 (06) : 1619 - 1622
  • [47] In situ Monitoring of Lysozyme Adsorption onto Bare and Cysteine- or 1-Octadecanethiol-Modified Au Electrodes Using an Electrochemical Quartz-Crystal Impedance System
    You-yu Zhang
    Qing-ji Xie
    An-hong Zhou
    Shou-zhuo Yao
    Analytical Sciences, 2000, 16 : 799 - 805
  • [48] In situ monitoring of lysozyme adsorption onto bare and cysteine- or 1-octadecanethiol-modified Au electrodes using an electrochemical quartz-crystal impedance system
    Zhang, YY
    Xie, QJ
    Zhou, AH
    Yao, SZ
    ANALYTICAL SCIENCES, 2000, 16 (08) : 799 - 805
  • [49] Electrochemical Quartz Crystal Microbalance and X-Ray Photoelectron Spectroscopy study of cathodic reactions in Bovine Serum Albumin containing solutions on a Physical Vapour Deposition-CoCrMo biomedical alloy
    Munoz, A. Igual
    Mischler, S.
    ELECTROCHIMICA ACTA, 2015, 180 : 96 - 103
  • [50] Binding of a chiral drug to a protein: an investigation of the 2-(3-benzoylphenyl) propionic acid/bovine serum albumin system by circular dichroism and fluorescence
    Monti, S
    Manoli, F
    Sortino, S
    Morrone, R
    Nicolosi, G
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2005, 7 (23) : 4002 - 4008