Multipoint temperature monitoring in liver undergoing Computed Tomography-guided Radiofrequency Ablation with fiber Bragg grating probes

被引:0
|
作者
Saccomandi, P. [1 ]
Schena, E. [2 ]
Diana, M. [1 ,3 ]
Di Matteo, F. M. [4 ]
Costamagna, G. [3 ,5 ]
Marescaux, J. [1 ,3 ]
机构
[1] IHU Strasbourg Inst Image Guided Surg, Strasbourg, France
[2] Univ Campus Biomed Roma, Unit Measurements & Biomed Instrumentat, Rome, Italy
[3] IRCAD Res Inst Canc Digest Syst, Strasbourg, France
[4] Univ Campus Biomed Roma, Unit Endoscopy, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Unit Digest Endoscopy, Policlin Gemelli, Rome, Italy
关键词
PORCINE PANCREAS; THERMAL ABLATION; LASER-ABLATION; TUMORS; EXPERIENCE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, we investigated the temperature increment experienced by biological tissue during radiofrequency ablation (RFA). The measurements were performed by using two custom-made thermal probes based on fiber optic sensors (fiber Bragg gratings, FBGs). The two probes embed a total of 9 FBGs. Experiments were performed during RFA of an ex vivo healthy porcine liver. The RFA heating module was equipped with 5 thermocouples. Results show that the temperature increment close to the applicator (i.e., 0.6 cm-0.7 cm) reaches the temperature which is set as a target on the RFA module (i.e., approximately 100 degrees C). The distance from the applicator also has an impact on the dynamics of the heating phenomenon: at short distances the tissue temperature reaches a steady state condition after a few minutes, on the other hand the sensors placed at a distance >= 2cm did not reach the steady-state conditions during the 14-minute procedure. The multipoint temperature monitoring, which uses sensors at several distances from the applicator, can provide useful information regarding the boundary of damaged volume. This approach can be combined with the monitoring temperature system embedded in the heating equipment, to better control the damaged volume, and to improve the treatment outcomes.
引用
收藏
页码:5176 / 5179
页数:4
相关论文
共 50 条
  • [31] Salvage computed tomography-guided transhepatic radiofrequency ablation for unresected aldosteronoma of adrenohepatic fusion after adrenalectomy
    Park, Jung Jae
    Park, Byung Kwan
    Kim, Jae Hyeon
    Jeong, Byong Chang
    Kim, Chan Kyo
    INTERNATIONAL JOURNAL OF UROLOGY, 2016, 23 (01) : 102 - 104
  • [32] Transcatheter Arterial Chemoembolization Combined with Simultaneous Computed Tomography-guided Radiofrequency Ablation for Large Hepatocellular Carcinomas
    Zuo, Tai-Yang
    Liu, Feng-Yong
    Wang, Mao-Qiang
    Chen, Xian-Xian
    CHINESE MEDICAL JOURNAL, 2017, 130 (22) : 2666 - 2673
  • [33] Monitoring of radiofrequency thermal ablation in liver tissue through fibre Bragg grating sensors array
    Tosi, D.
    Macchi, E. G.
    Braschi, G.
    Gallati, M.
    Cigada, A.
    Poeggel, S.
    Leen, G.
    Lewis, E.
    ELECTRONICS LETTERS, 2014, 50 (14) : 981 - U91
  • [34] Fiber Bragg grating based temperature profiling in ferromagnetic nanoparticles-enhanced radiofrequency ablation
    Jelbuldina, Madina
    Korobeinyk, Alina V.
    Korganbayev, Sanzhar
    Inglezakis, Vassilis J.
    Tosi, Daniele
    OPTICAL FIBER TECHNOLOGY, 2018, 43 : 145 - 152
  • [35] Feasibility of Noninvasive Temperature Assessment During Radiofrequency Liver Ablation on Computed Tomography
    Pandeya, Ganga D.
    Greuter, Marcel J. W.
    de Jong, Koert P.
    Schmidt, Bernhard
    Flohr, Thomas
    Oudkerk, Matthijs
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (03) : 356 - 360
  • [36] Prognostic Factors Influencing the Development of an Iatrogenic Pneumothorax for Computed Tomography-Guided Radiofrequency Ablation of Upper Renal Tumor
    Park, B. K.
    Kim, C. K.
    ACTA RADIOLOGICA, 2008, 49 (10) : 1200 - 1206
  • [37] Computed Tomography-Guided Radiofrequency Ablation of Osteoid Osteoma in Atypical Sites: Efficacy and Safety in a Large Case Series
    Niazi, Gamal Eldine
    Basha, Mohammad Abd Alkhalik
    Elsharkawi, Walid Feisal Ali
    Zaitoun, Mohamed M. A.
    ACADEMIC RADIOLOGY, 2021, 28 (01) : 68 - 76
  • [38] Percutaneous Computed Tomography-guided Renal Mass Radiofrequency Ablation versus Cryoablation: Doses of Sedation Medication Used
    Truesdale, Carl M.
    Soulen, Michael C.
    Clark, Timothy W. I.
    Mondschein, Jeffrey I.
    Wehrenberg-Klee, Eric
    Malkowicz, S. Bruce
    Wein, Alan J.
    Guzzo, Thomas J.
    Stavropoulos, S. William
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (03) : 347 - 350
  • [39] Laparoscopic and computed tomography-guided percutaneous radiofrequency ablation of renal tissue: Acute and chronic effects in an animal model
    Crowley, JD
    Shelton, J
    Iverson, AJ
    Burton, MP
    Dalrymple, NC
    Bishoff, JT
    UROLOGY, 2001, 57 (05) : 976 - 980
  • [40] Computed tomography-guided radiofrequency ablation of intra-articular osteoid osteoma: a single centre's experience
    Filippiadis, D. K.
    Velonakis, G.
    Kostantos, C.
    Kouloulias, V.
    Brountzos, E.
    Kelekis, N.
    Kelekis, A.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2017, 33 (06) : 670 - 674