On-line SPE sample treatment as a tool for method automatization and detection limits reduction: Quantification of 25-hydroxyvitamin D3/D2

被引:9
|
作者
Palaiogiannis, Dimitrios [1 ]
Bekou, Evangelia [1 ,3 ]
Pazaitou-Panayiotou, Kalliopi [2 ]
Samanidou, Victoria [3 ]
Tsakalof, Andreas [1 ]
机构
[1] Univ Thessaly, Biochem Lab, Fac Med, Larisa, Greece
[2] Theagenio Canc Hosp, Dept Endocrinol, Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Dept Chem, Thessaloniki, Greece
关键词
On-line solid phase extraction; Vitamin D; 25-Hydroxy vitamin D-3/D-2; Large volume injection; TANDEM MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; VITAMIN-D METABOLITES; LC-MS/MS; SERUM; ASSAYS; PROTEIN; PLASMA; SYSTEM; HPLC;
D O I
10.1016/j.jchromb.2016.10.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development and approbation of new, automated UHPLC-DAD method for the quantification of 25-hydroxyvitamin D-3/D-2 (250H-D-3/D-2) metabolites in plasma/serum for the evaluation of patient's vitamin D status are presented. The method was developed on the Ultimate 3000 UHPLC dual gradient system supplied with the on-line SPE-concentration column coupled through six port switching valve to analytical column. This configuration and materials selected enable large volume sample injection (500 mu L) and online sample preconcentration, clean up and subsequent selective metabolites transfer onto the analytical column. The new method abrogates main conventional time consuming and error source off-line steps of analysis and thus simplifies analysis. The large volume injection increases the sensitivity of instrumental analysis by about ten-fold on-line pre-concentration of metabolites. The instrument response is linear (R> 0.99) in the investigated concentration range 10-100 ng mL(-1) which covers all the possible vitamin D status from serious deficiency (<12 ngmL(-1)) to excess. The method detection limits (S/N = 3) are LOD (25OH-D-3) = 0.94 ngmL(-1) and LOD (250H-D-2) = 2.4 ngmL(-1). The method performance was assessed with the use of certified reference samples and perfect agreement between certified and measured values is demonstrated. The method was applied to human samples previously analyzed for total vitamin D by Competitive Protein-binding assay and findings of the two methods are compared. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:219 / 227
页数:9
相关论文
共 50 条
  • [31] Treatment of an Intramammary Bacterial Infection with 25-Hydroxyvitamin D3
    Lippolis, John D.
    Reinhardt, Timothy A.
    Sacco, Randy A.
    Nonnecke, Brian J.
    Nelson, Corwin D.
    PLOS ONE, 2011, 6 (10):
  • [32] DETERMINATION OF 25-HYDROXYVITAMIN D2 AND 25-HYDROXYVITAMIN D3 IN HUMAN-PLASMA USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY
    EISMAN, JA
    SHEPARD, RM
    DELUCA, HF
    ANALYTICAL BIOCHEMISTRY, 1977, 80 (01) : 298 - 305
  • [33] High-performance liquid chromatography and coulometric electrode array detector in serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 analyses
    Nurmi, Tarja
    Tuomainen, Tomi-Pekka
    Virtanen, Jyrki
    Mursu, Jaakko
    Voutilainen, Sari
    ANALYTICAL BIOCHEMISTRY, 2013, 435 (01) : 1 - 9
  • [34] Potencies of vitamin D analogs, 1-hydroxyvitamin D3, 1-hydroxyvitamin D2 and 25-hydroxyvitamin D3, in lowering cholesterol in hypercholesterolemic mice in vivo
    Quach, Holly P.
    Dzekic, Tamara
    Bukuroshi, Paola
    Pang, K. Sandy
    BIOPHARMACEUTICS & DRUG DISPOSITION, 2018, 39 (04) : 196 - 204
  • [35] 25-Hydroxyvitamin D2/D3 Analysis in Human Plasma Using LC-MS
    Koerner, Phil
    McGinley, Michael
    LC GC NORTH AMERICA, 2011, : 70 - 73
  • [36] Serum 25-Hydroxyvitamin D3 and D2 and Non-Clinical Psychotic Experiences in Childhood
    Tolppanen, Anna-Maija
    Sayers, Adrian
    Fraser, William D.
    Lewis, Glyn
    Zammit, Stanley
    McGrath, John
    Lawlor, Debbie A.
    PLOS ONE, 2012, 7 (07):
  • [37] 25-Hydroxyvitamin D2/D3 Analysis in Human Plasma Using LC-MS
    Koerner, Phil
    McGinley, Michael
    LC GC NORTH AMERICA, 2011, : 8 - 11
  • [38] Simultaneous determination of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human serum by ultra performance liquid chromatography: An economical and validated method with bovine serum albumin
    Chin, Siok-Fong
    Osman, Junaida
    Jamal, Rahman
    CLINICA CHIMICA ACTA, 2018, 485 : 60 - 66
  • [39] Current assays overestimate 25-hydroxyvitamin D3 and underestimate 25-hydroxyvitamin D2 compared with HPLC:: need for assay-specific decision limits and metabolite-specific assays
    Glendenning, P
    Taranto, M
    Noble, JM
    Musk, AA
    Hammond, C
    Goldswain, PR
    Fraser, WD
    Vasikaran, SD
    ANNALS OF CLINICAL BIOCHEMISTRY, 2006, 43 : 23 - 30
  • [40] Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma
    Zhang, Stanley
    Jian, Wenying
    Sullivan, Sheryl
    Sankaran, Banu
    Edom, Richard W.
    Weng, Naidong
    Sharkey, David
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 961 : 62 - 70