This study presents an optical inspection system for detecting a commercial point-of-care testing product and a new detection model covering from qualitative to quantitative analysis. Human chorionic gonadotropin (hCG) strips (cut-off value of the hCG commercial product is 25 mIU/mL) were the detection target in our study. We used a complementary metal-oxide semiconductor (CMOS) sensor to detect the colors of the test line and control line in the specific strips and to reduce the observation errors by the naked eye. To achieve better linearity between the grayscale and the concentration, and to decrease the standard deviation (increase the signal to noise ratio, S/N), the Taguchi method was used to find the optimal parameters for the optical inspection system. The pregnancy test used the principles of the lateral flow immunoassay, and the colors of the test and control line were caused by the gold nanoparticles. Because of the sandwich immunoassay model, the color of the gold nanoparticles in the test line was darkened by increasing the hCG concentration. As the results reveal, the S/N increased from 43.48 dB to 53.38 dB, and the hCG concentration detection increased from 6.25 to 50 mIU/mL with a standard deviation of less than 10%. With the optimal parameters to decrease the detection limit and to increase the linearity determined by the Taguchi method, the optical inspection system can be applied to various commercial rapid tests for the detection of ketamine, troponin I, and fatty acid binding protein (FABP).
引用
收藏
页码:16148 / 16158
页数:11
相关论文
共 50 条
  • [31] An integrated and automated electronic system for point-of-care protein testing
    Wu, D.
    Voldman, J.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1571 - 1574
  • [32] Recent advances in point-of-care testing (POCT) system based on upconversion luminescent materials☆
    Bian, Shunuo
    Jin, Tao
    Lu, Wenqiang
    MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2025, 314
  • [33] CRP detection from serum for chip-based point-of-care testing system
    Kim, Chang-Hoon
    Ahn, Jae-Hyuk
    Kim, Jee-Yeon
    Choi, Ji-Min
    Lim, Kyung-Choon
    Park, Tae Jung
    Heo, Nam Su
    Lee, Hee Gu
    Kim, Jong-Wan
    Choi, Yang-Kyu
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 322 - 327
  • [34] Optical sensing of anticoagulation status: Towards point-of-care coagulation testing
    Tshikudi, Diane M.
    Tripathi, Markandey M.
    Hajjarian, Zeinab
    Van Cott, Elizabeth M.
    Nadkarni, Seemantini K.
    PLOS ONE, 2017, 12 (08):
  • [35] Reigning in the Point-of-Care Beast: Assessing Quality of Point-of-Care Testing Within the Ambulatory Network of a Large Health System
    Arboleda, Valerie
    Garner, Omai
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2017, 147 : S157 - +
  • [36] Advancing magnetic flow cytometry to quantitative epitope analysis in high hematocrit conditions for point-of-care testing
    Leuthner, Moritz
    Helou, Michael
    Reisbeck, Mathias
    Hayden, Oliver
    BIOSENSORS & BIOELECTRONICS, 2025, 268
  • [37] Pt@AuNPs integrated quantitative capillary-based biosensors for point-of-care testing application
    Wu, Ze
    Fu, Qiangqiang
    Yu, Shiting
    Sheng, Liangrong
    Xu, Meng
    Yao, Cuize
    Xiao, Wei
    Li, Xiuqing
    Tang, Yong
    BIOSENSORS & BIOELECTRONICS, 2016, 85 : 657 - 663
  • [38] Proteolytic reaction-based versatile electrochemical biosensor chip for simple and quantitative point-of-care testing
    Park, Seonhwa
    Kim, Gyeongho
    Yang, Haesik
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 414
  • [39] Concentration cell-based potentiometric analysis for point-of-care testing with minimum background
    Sun, Mi
    Li, Zhiyang
    Xia, Yanyan
    Zhao, Chao
    Liu, Hong
    ANALYTICA CHIMICA ACTA, 2019, 1046 : 110 - 114
  • [40] Paper based point-of-care testing disc for multiplex whole cell bacteria analysis
    Li, Chen-zhong
    Vandenberg, Katherine
    Prabhulkar, Shradha
    Zhu, Xuena
    Schneper, Lisa
    Methee, Kalai
    Rosser, Charles J.
    Almeide, Eugenio
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (11): : 4342 - 4348