Simultaneous monitoring of cerebral metal accumulation in an experimental model of Wilson's disease by laser ablation inductively coupled plasma mass spectrometry

被引:27
|
作者
Boaru, Sorina Georgiana [1 ]
Merle, Uta [2 ]
Uerlings, Ricarda [1 ]
Zimmermann, Astrid [3 ]
Weiskirchen, Sabine [1 ]
Matusch, Andreas [4 ]
Stremmel, Wolfgang [2 ]
Weiskirchen, Ralf [1 ]
机构
[1] RWTH Aachen Univ Hosp Aachen, Inst Clin Chem & Pathobiochem, D-52074 Aachen, Germany
[2] Univ Clin Heidelberg, Dept Gastroenterol, Heidelberg, Germany
[3] Res Ctr Julich FZJ, Cent Inst Engn Elect & Analyt ZEA 3, Julich, Germany
[4] Res Ctr Julich FZJ, Inst Neurosci & Med INM 2, Julich, Germany
来源
BMC NEUROSCIENCE | 2014年 / 15卷
关键词
Wilson's disease; Bio-imaging; LA-ICP-MS; Copper; ATPase7B; COPPER TRANSPORTING ATPASE; NECROSIS-FACTOR-ALPHA; TOXIC MILK MOUSE; MENKES DISEASE; MURINE MODEL; ANIMAL-MODEL; BRAIN; GENE; MICE; METABOLISM;
D O I
10.1186/1471-2202-15-98
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Neuropsychiatric affection involving extrapyramidal symptoms is a frequent component of Wilson's disease (WD). WD is caused by a genetic defect of the copper (Cu) efflux pump ATPase7B. Mouse strains with natural or engineered transgenic defects of the Atp7b gene have served as model of WD. These show a gradual accumulation and concentration of Cu in liver, kidneys, and brain. However, still little is known about the regional distribution of Cu inside the brain, its influence on other metals and subsequent pathophysiological mechanisms. We have applied laser ablation inductively coupled plasma mass spectrometry and performed comparative metal bio-imaging in brain sections of wild type and Atp7b null mice in the age range of 11-24 months. Messenger RNA and protein expression of a panel of inflammatory markers were assessed using RT-PCR and Western blots of brain homogenates. Results: We could confirm Cu accumulation in brain parenchyma by a factor of two in WD (5.5 mu g g(-1) in the cortex) vs. controls (2.7 mu g g(-1)) that was already fully established at 11 months. In the periventricular regions (PVR) known as structures of prominent Cu content, Cu was reduced in turn by a factor of 3. This corroborates the view of the PVR as efflux compartments with active transport of Cu into the cerebrospinal fluid. Furthermore, the gradient of Cu increasing downstream the PVR was relieved. Otherwise the architecture of Cu distribution was essentially maintained. Zinc (Zn) was increased by up to 40% especially in regions of high Cu but not in typical Zn accumulator regions, a side effect due to the fact that Zn is to some degree a substrate of Cu-ATPases. The concentrations of iron (Fe) and manganese (Mn) were constant throughout all regions assessed. Inflammatory markers TNF-alpha, TIMP-1 and the capillary proliferation marker alpha-SMA were increased by a factor of 2-3 in WD. Conclusions: This study confirmed stable cerebral Cu accumulation in parenchyma and discovered reduced Cu in cerebrospinal fluid in Atp7b null mice underlining the diagnostic value of micro-local analytical techniques.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Element bioimaging of liver needle biopsy specimens from patients with Wilson's disease by laser ablation-inductively coupled plasma-mass spectrometry
    Hachmoeller, Oliver
    Aichler, Michaela
    Schwamborn, Kristina
    Lutz, Lisa
    Werner, Martin
    Sperling, Michael
    Walch, Axel
    Karst, Uwe
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2016, 35 : 97 - 102
  • [42] The effects of He on ablation and inductively coupled plasma environment in ultra-violet, nanosecond laser ablation inductively coupled plasma mass spectrometry
    Moses, Lance M.
    Farnsworth, Paul B.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 113 : 138 - 146
  • [43] Lead determination in whole blood by laser ablation coupled with inductively coupled plasma mass spectrometry
    Hsieh, Hui-Fang
    Chang, Wei-Shan
    Hsieh, Yi-Kong
    Wang, Chu-Fang
    TALANTA, 2009, 79 (02) : 183 - 188
  • [44] Capabilities of femtosecond laser ablation inductively coupled plasma mass spectrometry for depth profiling of thin metal coatings
    Pisonero, J.
    Koch, J.
    Waelle, M.
    Hartung, W.
    Spencer, N. D.
    Guenther, D.
    ANALYTICAL CHEMISTRY, 2007, 79 (06) : 2325 - 2333
  • [45] QUANTITATIVE-ANALYSIS OF GLASS USING INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION AND MASS-SPECTROMETRY, LASER MICROANALYSIS INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AND LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    MOENKEBLANKENBURG, L
    SCHUMANN, T
    GUNTHER, D
    KUSS, HM
    PAUL, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) : 251 - 254
  • [46] Theoretical description and experimental observation of aerosol transport processes in laser ablation inductively coupled plasma mass spectrometry
    Bleiner, D
    Günther, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) : 449 - 456
  • [47] Femtosecond laser ablation: Experimental study of the repetition rate influence on inductively coupled plasma mass spectrometry performance
    Gonzalez, Jhanis J.
    Fernandez, Alberto
    Oropeza, Dayana
    Mao, Xianglei
    Russo, Richard E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (02) : 277 - 286
  • [48] Quantitative analysis for impurities in uranium by laser ablation inductively coupled plasma mass spectrometry: Improvements in the experimental setup
    Leloup, C
    Marty, P
    DallAva, D
    Perdereau, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) : 945 - 950
  • [49] Application of laser ablation inductively coupled plasma-mass spectrometry in dendrochemical analysis
    Watmough, SA
    Hutchinson, TC
    Evans, RD
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (01) : 114 - 118
  • [50] Review of the State-of-the-Art of Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Koch, Joachim
    Guenther, Detlef
    APPLIED SPECTROSCOPY, 2011, 65 (05) : 155A - 162A