Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Balloon-Expandable Transcatheter Heart Valve A Single-Center Experience

被引:45
|
作者
Husser, Oliver [1 ]
Pellegrini, Costanza [1 ]
Kessler, Thorsten [1 ]
Burgdorf, Christof [1 ]
Thaller, Hannah [1 ]
Mayr, N. Patrick [2 ]
Ott, Ilka [1 ]
Kasel, Albert M. [1 ]
Schunkert, Heribert [1 ,3 ]
Kastrati, Adnan [1 ,3 ]
Hengstenberg, Christian [1 ,3 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum Munchen, Klin Herz & Kreislauferkrankungen, D-80636 Munich, Germany
[2] Tech Univ Munich, Deutsch Herzzentrum Munchen, Inst Anasthesiol, D-80636 Munich, Germany
[3] Deutsch Zentrum Herz & Kreislauf Forsch DZHK eV, German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, Munich, Germany
关键词
aortic valve stenosis; outcome; SAPIEN; 3; transfemoral transcatheter aortic valve implantation; VARC-2; PERMANENT PACEMAKER IMPLANTATION; SAPIEN; 3; EDWARDS SAPIEN; VASCULAR COMPLICATIONS; RISK; STENOSIS; METAANALYSIS; DEFINITIONS; PREDICTORS; COREVALVE;
D O I
10.1016/j.jcin.2015.08.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Evaluation of 30-day outcomes after transcatheter aortic valve replacement (TAVR) with the novel balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV) (Edwards Lifesciences, Irvine, California) emphasizing the updated Valve Academic Research Consortium (VARC-2) criteria. BACKGROUND Preliminary data on clinical performance with the S3 THV are promising. However, information regarding 30-day outcome is limited. METHODS A total of 250 consecutive patients undergoing transfemoral TAVR with the S3 THV at our center were enrolled, and outcomes according to VARC-2 criteria were analyzed at 30 days. RESULTS The mean age was 81.0 +/- 6.2 years, median logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) and Society of Thoracic Surgeons score were 12.1% and 4.4%, respectively. VARC-2-defined device success was achieved in 244 patients (97.6%); moderate paravalvular leakage developed in 5 patients (2.0%). One patient (0.4%) died of a noncardiac cause and 8 patients (3.2%) had a stroke. Life-threatening bleeding and major vascular complications occurred in 12 (4.8%) and 9 (3.6%) of the patients, respectively. From discharge to 30 days, 5 patients (2.0%) were hospitalized due to valve-related symptoms or worsening of heart failure. The VARC-2 composite early safety endpoint was observed in 25 patients (10.0%). Permanent pacemaker implantation rate at 30 days was 15.2%. Myocardial infarction, coronary obstruction requiring intervention, valve-related dysfunction, and endocarditis were not observed. CONCLUSIONS We found very good 30-day results using the novel S3 THV with a low rate of clinical events according to VARC-2 criteria. The S3 THV is associated with high procedural success and favorable early safety profile. The need for pacemaker implantations appears to be more frequent than with its predecessor. (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:1809 / 1816
页数:8
相关论文
共 50 条
  • [31] Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A NationWide Study
    Sa, Young Kyoung
    Choi, Ik Jun
    Chang, Kiyuk
    Hwang, Byung-Hee
    Chung, Woo-Baek
    Lee, Kwan Yong
    Choo, Eun-Ho
    Kim, Chan Joon
    Park, Mahn Won
    Choi, Yoon Seok
    Park, Chul Soo
    Yoo, Ki Dong
    Jeon, Doo Soo
    Oak, Min -Ho
    Lee, Jungkuk
    Kang, Dongwoo
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 213 : 119 - 125
  • [32] Transcatheter mitral valve-in-valve replacement transeptally using a novel balloon-expandable device
    Drakopoulou, Maria
    Latsios, George
    Synetos, Andreas
    Benetos, Georgios
    Soulaidopoulos, Stergios
    Oikonomou, Georgios
    Apostolos, Anastasios
    Aggeli, Konstantina
    Lozos, Vasilios
    Lymperiadis, Dimitrios
    Tsioufis, Konstantinos
    Toutouzas, Konstantinos
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (10) : 3376 - 3377
  • [33] Commissural Alignment After Balloon-Expandable Transcatheter Aortic Valve Replacement Is Associated With Improved Hemodynamic Outcomes
    Raschpichler, Matthias
    Flint, Nir
    Yoon, Sung-Han
    Kaewkes, Danon
    Patel, Chinar
    Singh, Chetana
    Patel, Vivek
    Kashif, Mohammad
    Borger, Michael A.
    Chakravarty, Tarun
    Makkar, Raj
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (11) : 1126 - 1136
  • [34] Balloon-Expandable Device for Non-Aortic Valve in Valve Transcatheter Heart Valve Implantation
    Williams, Judson
    Sherwood, Matthew M.
    Wang, Andrew
    Gaca, Jeffrey G.
    CARDIOLOGY, 2016, 134 (02) : 239 - 239
  • [35] Transcatheter aortic valve implantation with balloon-expandable valve: early experience from China
    Lu, Qingsheng
    Pei, Yifei
    Wu, Hong
    Wang, Zhinong
    Jing Zaiping
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2015, 30 (04): : 425 - 432
  • [36] Aortic Angulation Does Not Impact Outcomes in Self-Expandable or Balloon-Expandable Transcatheter Aortic Valve Replacement
    Elmously, Adham
    Gray, Katherine D.
    Truong, Quynh A.
    Burshtein, Aaron
    Wong, S. Chiu
    de Biasi, Andreas R.
    Worku, Berhane
    Salemi, Arash
    CARDIOLOGY, 2018, 140 (02) : 96 - 102
  • [37] THE IMPACT OF GENDER ON OUTCOMES OF THE TRANSCATHETER AORTIC VALVE BETWEEN SELF-EXPANDABLE VALVE AND BALLOON-EXPANDABLE VALVE
    Tateishi, Kazuya
    Hmoud, Hosam
    Hastings, Ramin
    De Gregorio, Joseph A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 917 - 917
  • [38] Late migration of balloon-expandable transcatheter aortic valve
    Lauten, Alexander
    Hamadanchi, Ali
    Doenst, Torsten
    Figulla, Hans R.
    EUROPEAN HEART JOURNAL, 2013, 34 (32) : 2509 - 2509
  • [39] Effects of implantation height on the performance of a redo transcatheter aortic valve replacement using a balloon-expandable valve
    Chen, Huang
    Samaee, Milad
    Yadav, Pradeep
    Thourani, Vinod
    Dasi, Lakshmi Prasad
    JTCVS OPEN, 2024, 19 : 61 - 67
  • [40] Long-term outcomes and prosthesis performance after transcatheter aortic valve replacement: results of self-expandable and balloon-expandable transcatheter heart valves
    Tarantini, Giuseppe
    Purita, Paola A. M.
    D'Onofrio, Augusto
    Fraccaro, Chiara
    Frigo, Anna Chiara
    D'Amico, Gianpiero
    Fovino, Luca Nai
    Martin, Marta
    Cardaioli, Francesco
    Badawy, Mostafa R. A.
    Napodano, Massimo
    Gerosa, Gino
    Iliceto, Sabino