The range of axial rotation of the glenohumeral joint

被引:9
|
作者
Southgate, Dominic F. L. [1 ,2 ]
Hill, Adam M. [1 ,4 ]
Alexander, Susan [3 ]
Wallace, Andrew L. [3 ]
Hansen, Ulrich N. [2 ]
Bull, Anthony M. J. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Mech Engn, London SW7 2AZ, England
[3] Hosp St John & St Elizabeth, Shoulder Unit, London, England
[4] Univ London Imperial Coll Sci Technol & Med, Fac Med, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
Shoulder; Stability; Six degrees of freedom; EXTERNAL ROTATION; BIOMECHANICAL PROPERTIES; THROWERS SHOULDER; LIGAMENT; MOTION; STABILITY; MODEL; KINEMATICS; RESTRAINTS; BEHAVIOR;
D O I
10.1016/j.jbiomech.2009.03.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
There is a paucity of data in the literature on the restraining effects of the glenohumeral (GH) ligaments; cadaveric testing is one of the best methods for determining the function of these types of tissues. The aim of this work was to commission a custom-made six degrees of freedom (dof) joint loading apparatus and to establish a protocol for laxity testing of cadaveric shoulder specimens. Nine cadaveric shoulder specimens were used in this study and each specimen had all muscle resected leaving the scapula, humerus (transected at mid-shaft) and GH capsule. Specimens were mounted on the testing apparatus with the joint in the neutral position and at 30 degrees, 60 degrees and 90 degrees GH abduction in the coronal. scapula and 30 degrees forward flexion planes. For each orientation, 0-1 N m in 0.1 N m increments was applied in internal/external rotation and the angular displacement recorded. The toe-region of the moment-displacement curves ended at approximately +/- 0.5Nm. The highest rotational range of motion for the joint was 140 degrees for +/- 1.0 N m at 30 degrees o GH abduction in the scapula plane. The range of motion shifted towards external rotation with increasing levels of abduction. The results provide the optimum loading regime to pre-condition shoulder specimens and minimise viscoelastic effects in the ligaments prior to laxity testing (> 0.5 N m at 30 degrees GH abduction in any of the three planes). Knowledge of the mechanical properties of the GH capsuloligamentous complex has implications for modelling of the shoulder as well surgical planning and intervention. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1307 / 1312
页数:6
相关论文
共 50 条
  • [21] THE INFERIOR STABILITY PROVIDED BY THE GLENOHUMERAL CAPSULE INCREASES WITH EXTERNAL ROTATION IN THE ABDUCTED GLENOHUMERAL JOINT
    Drury, Nicholas J.
    Ellis, Benjamin J.
    McMahon, Patrick J.
    Weiss, Jeffrey A.
    Debski, Richard E.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 483 - 484
  • [22] The effects of prosthetic humeral head shape on glenohumeral joint kinematics during humeral axial rotation in total shoulder arthroplasty
    Jun, Bong Jae
    Lee, Thay Q.
    McGarry, Michelle H.
    Quigley, Ryan J.
    Shin, Sang Jin
    Iannotti, Joseph P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (07) : 1084 - 1093
  • [23] Glenohumeral elevation-dependent influence of anterior glenohumeral capsular lesions on passive axial humeral rotation
    Jansen, Justus H. W.
    de Gast, Arthur
    Snijders, Chris J.
    JOURNAL OF BIOMECHANICS, 2006, 39 (09) : 1702 - 1707
  • [24] Kinematic coupling of the glenohumeral and scapulothoracic joints generates humeral axial rotation
    Aliaj, Klevis
    Lawrence, Rebekah L.
    Foreman, K. Bo
    Chalmers, Peter N.
    Henninger, Heath B.
    JOURNAL OF BIOMECHANICS, 2022, 136
  • [25] Modeling the stability of the human glenohumeral joint during external rotation
    Novotny, JE
    Beynnon, BD
    Nichols, CE
    JOURNAL OF BIOMECHANICS, 2000, 33 (03) : 345 - 354
  • [26] Passive axial rotation of the metacarpophalangeal joint
    Krishnan, J
    Chipchase, L
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1997, 22B (02): : 270 - 273
  • [27] Beyond Euler/Cardan analysis: True glenohumeral axial rotation during arm elevation and rotation
    Aliaj, Klevis
    Foreman, K. Bo
    Chalmers, Peter N.
    Henninger, Heath B.
    GAIT & POSTURE, 2021, 88 : 28 - 36
  • [28] MR arthrography of the glenohumeral joint: Comparison of neutral, external rotation, and abduction external rotation in the evaluation of the joint capsule, biceps-labral complex and glenohumeral ligaments
    Kwak, SM
    Brown, RR
    Trudell, DT
    Resnick, DL
    RADIOLOGY, 1997, 205 : 414 - 414
  • [29] The Effect of Glenohumeral Internal Rotation Deficit Due to Posterior Capsular Contracture on Passive Glenohumeral Joint Motion
    Gates, Jeffrey J.
    Gupta, Akash
    McGarry, Michelle H.
    Tibone, James E.
    Lee, Thay Q.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (12): : 2794 - 2800
  • [30] In vivo kinematic analysis of the glenohumeral joint during dynamic full axial rotation and scapular plane full abduction in healthy shoulders
    Naoya Kozono
    Takamitsu Okada
    Naohide Takeuchi
    Satoshi Hamai
    Hidehiko Higaki
    Satoru Ikebe
    Takeshi Shimoto
    Go Miake
    Yoshitaka Nakanishi
    Yukihide Iwamoto
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2032 - 2040