Variations in vacuum gap location in a microsecond plasma opening switch

被引:3
|
作者
Lisitsyn, IV
Kohno, S
Kawauchi, T
Akiyama, H
机构
[1] Dept. of Elec. and Comp. Engineering, Kumamoto University, Kumamoto 860
关键词
D O I
10.1063/1.120041
中图分类号
O59 [应用物理学];
学科分类号
摘要
The process of vacuum gap formation in a microsecond plasma opening switch has been studied using a He-Ne laser interferometer, Time and spatially resolved density measurements are performed in the plasma opening switch, showing a density decrease during switch opening in almost the whole interelectrode gap. Despite fine triggering accuracy and generally good shot-to-shot reproducibility of voltage and current waveforms, measurements made with the same laser beam location indicated remarkable shot-to-shot variation. The unstable formation of the vacuum gap in the microsecond plasma opening switch may be a major limiting factor for efficient switch operation. (C) 1997 American Institute of Physics.
引用
收藏
页码:2251 / 2252
页数:2
相关论文
共 50 条
  • [21] Operation of microsecond plasma opening switches
    S. V. Loginov
    Technical Physics, 2009, 54 : 62 - 67
  • [23] GAP FORMATION PROCESSES IN A HIGH-DENSITY PLASMA OPENING SWITCH
    GROSSMANN, JM
    SWANEKAMP, SB
    OTTINGER, PF
    COMMISSO, RJ
    HINSHELWOOD, DD
    WEBER, BV
    PHYSICS OF PLASMAS, 1995, 2 (01) : 299 - 309
  • [24] Plasma dynamics in microsecond megaampere plasma opening switches
    Loginov, S. V.
    PHYSICS OF PLASMAS, 2011, 18 (10)
  • [25] Dynamics of the plasma injected into the gap of a plasma opening switch across a strong magnetic field
    G. I. Dolgachev
    D. D. Maslennikov
    A. G. Ushakov
    A. S. Fedotkin
    I. A. Khodeev
    A. A. Shvedov
    Plasma Physics Reports, 2011, 37 : 171 - 176
  • [26] Dynamics of the plasma injected into the gap of a plasma opening switch across a strong magnetic field
    Dolgachev, G. I.
    Maslennikov, D. D.
    Ushakov, A. G.
    Fedotkin, A. S.
    Khodeev, I. A.
    Shvedov, A. A.
    PLASMA PHYSICS REPORTS, 2011, 37 (02) : 171 - 176
  • [27] NEON GAS PUFF IMPLOSIONS ON A HIGH-CURRENT MICROSECOND GENERATOR WITH AND WITHOUT A PLASMA OPENING SWITCH
    DEENEY, C
    LEPELL, PD
    ROTH, I
    NASH, T
    WARREN, L
    PRASAD, RR
    MCDONALD, C
    CHILDERS, FK
    SINCERNY, P
    COULTER, MC
    WHITNEY, KG
    JOURNAL OF APPLIED PHYSICS, 1992, 72 (04) : 1297 - 1305
  • [28] Scaling microsecond-conduction-time plasma opening switch operation from 2 to 5 MA
    Rix, W
    Coleman, P
    Thompson, JR
    Husovsky, D
    Melcher, P
    Commisso, RJ
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1997, 25 (02) : 169 - 175
  • [29] A high-current pulse generator SIGNAL with an inductive energy storage and a microsecond plasma opening switch
    Gafarov, AM
    Kovalev, VP
    Safronov, AA
    Vagina, NM
    Vorozhtsov, VI
    Grabovenskii, SI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2001, 44 (01) : 61 - 66
  • [30] A High-Current Pulse Generator SIGNAL with an Inductive Energy Storage and a Microsecond Plasma Opening Switch
    A. M. Gafarov
    V. P. Kovalev
    A. A. Safronov
    N. M. Vagina
    V. I. Vorozhtsov
    S. I. Grabovenskii
    Instruments and Experimental Techniques, 2001, 44 : 61 - 66