Determination of reproducibility of end-exhaled breath-holding in stereotactic body radiation therapy

被引:2
|
作者
Sasaki, Motoharu [1 ]
Ikushima, Hitoshi [1 ]
Sakuragawa, Kanako [2 ]
Yokoishi, Michihiro [2 ]
Tsuzuki, Akira [3 ]
Sugimoto, Wataru [4 ]
机构
[1] Tokushima Univ Grad Sch, Inst Biomed Sci, Dept Therapeut Radiol, 3-18-15 Kuramoto Cho, Tokushima, Tokushima 7708503, Japan
[2] Tokushima Univ Hosp, Dept Radiol Technol, 2-50-1 Kuramoto Cho, Tokushima, Tokushima 7708503, Japan
[3] Kochi Med Sch Hosp, Dept Radiol Technol, 185-1 Kohasu, Nankoku, Kochi 7838505, Japan
[4] Tokushima Prefectural Cent Hosp, Dept Radiol Technol, 1-10-3 Kuramoto Cho, Tokushima, Tokushima 7708539, Japan
关键词
dice similarity coefficient; Hausdorff distance; breath-hold irradiation; lung cancer; LUNG-TUMOR POSITION; RADIOTHERAPY; REGISTRATION; CANCER;
D O I
10.1093/jrr/rraa079
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Methods to evaluate the positional reproducibility of breath-hold irradiation mostly require manual operation. The purpose of this study is to propose a method to determine the reproducibility of breath-hold irradiation of lung tumors between fractions using non-artificial methods. This study included 13 patients who underwent terminal exhaled breath-hold irradiation for primary and metastatic lung cancer. All subjects received a prescribed dose of 60 Gy/8 fractions. The contours of the gross tumor volume (GTV) were extracted by threshold processing using treatment-planning computed tomography (CT) and cone-beam CT (CBCT), which was done just before the beginning of the treatment. The method proposed in this study evaluates the dice similarity coefficient (DSC) and Hausdorff distance (HD) by comparing two volumes, the GTV(CTS) (GTV obtained from treatment-planning CT) and GTV(CBCT) (GTV obtained from CBCT). The reference contours for DSC and HD are represented by GTV(CTS). The results demonstrated good visual agreement for cases with a DSC of similar to 0.7. However, apparent misalignment occurred when the DSC was <0.5. HD was >2 mm in 3 out of 13 cases, and when the DSC was similar to 0.7, the HD was similar to 1 mm. In addition, cases with greater HD also demonstrated more significant variability. It was found that the DSC and HD evaluation methods for the positional reproducibility of breath-hold irradiation proposed in this study are straightforward and can be performed without the involvement of humans. Our study is of extreme significance in the field of radiation studies.
引用
收藏
页码:977 / 984
页数:8
相关论文
共 50 条
  • [21] Breath-Holding Volumetric Modulated Radiation Therapy Based on Implanted Fiducial Marks Using the Image Guided Radiation Therapy System With Fluoroscopic Function
    Takanaka, T.
    Kumano, T.
    Minami, T.
    Koda, W.
    Matsui, O.
    Noto, K.
    Ueda, S.
    Kurata, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S149 - S150
  • [22] PBTK modeling demonstrates contribution of dermal and inhalation exposure components to end-exhaled breath concentrations of naphthalene
    Kim, David
    Andersen, Melvin E.
    Chao, Yi-Chun E.
    Egehy, Peter P.
    Rappaport, Stephen M.
    Nylander-French, Leena A.
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2007, 115 (06) : 894 - 901
  • [23] Risk of Radiation Pneumonitis Following Individualized Modern Radiation Therapy with IMRT, a Breath-Holding Technique and Prone Positioning for Breast Cancer
    Lee, B. M.
    Chang, J. S.
    Keum, K. C.
    Suh, C. O.
    Kim, Y. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S45 - S45
  • [24] Does iron therapy have a place in the management of all breath-holding spells?
    Arslan, Mujgan
    Karaibrahimoglu, Adnan
    Demirtas, Mehmet Semih
    PEDIATRICS INTERNATIONAL, 2021, 63 (11) : 1344 - 1350
  • [25] Determination of ELISA reproducibility to detect protein markers in exhaled breath condensate
    Nunez-Naveira, Laura
    Marinas-Pardo, Luis A.
    Amor-Carro, Oscar
    Montero-Martinez, Carmen
    JOURNAL OF BREATH RESEARCH, 2012, 6 (04)
  • [26] Breath-holding spells: Waiting to inhale, waiting for systole, or waiting for iron therapy?
    Hannon, DW
    JOURNAL OF PEDIATRICS, 1997, 130 (04): : 510 - 512
  • [27] Effect of Fluoxetine Therapy on Breath-Holding Spells in Children: A Clinical Trial Study
    Farzadfard, Seyedeh Zahra
    Ashrafzadeh, Farah
    Toosi, Mehran Beiraghi
    Majd, Hassan Mahrad
    Shahabifar, Mahinosadat
    INTERNATIONAL JOURNAL OF PEDIATRICS-MASHHAD, 2020, 8 (01): : 10775 - +
  • [28] End-to-end test of respiratory gating radiation therapy for lung stereotactic body radiation therapy treatments
    Milovan Savanović
    Bojan Štrbac
    Dražan Jaroš
    Catherine Jenny
    Jean-Noël Foulquier
    Radiation and Environmental Biophysics, 2022, 61 : 651 - 660
  • [29] End-to-end test of respiratory gating radiation therapy for lung stereotactic body radiation therapy treatments
    Savanovic, Milovan
    Strbac, Bojan
    Jaros, Drazan
    Jenny, Catherine
    Foulquier, Jean-Noel
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2022, 61 (04) : 651 - 660
  • [30] Comparison of the Reproducibility of Tumor Positions in the Liver and Upper Abdomen With Those in the Lung With Exhalation Breath-Holding Methods
    Baba, F.
    Shibamoto, Y.
    Iwana, M.
    Nomura, K.
    Sasaki, S.
    Nagayoshi, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E135 - E136