Spectral characteristics of mechanical heart valve closing sounds

被引:0
|
作者
Johansen, P [1 ]
Lomholt, M [1 ]
Nygaard, H [1 ]
机构
[1] Aarhus Univ Hosp, Skejby Sygehus, Dept Cardiothorac & Vasc Surg, DK-8200 Aarhus N, Denmark
来源
JOURNAL OF HEART VALVE DISEASE | 2002年 / 11卷 / 05期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: In-vivo evaluation of cavitation is based on the registration of high-frequency pressure fluctuations that represent a mixture of both cavitation and valve dosing sounds, and are difficult to separate. In order to extract the cavitation signal, a high-pass filter removing the closing sound is applied. Importantly, the cut-off frequency should be chosen based on the valve's resonance pattern. This could be determined in a cavitation-free, air-operated set-up. As air and water/blood have different physical properties that could influence resonance frequencies, it is necessary to correlate the frequency content of the closing sounds recorded in air to represent expected findings in fluid. The study aim was to characterize the impact of the surrounding media on resonance frequency of a sound source, and to develop a method capable of evaluating the spectral characteristics of mechanical heart valves. Methods: Five different valves were investigated. An in-vitro set-up was developed where the valves were operated in an airflow-controlled setting without cavitation. The valve closing sounds were recorded and a spectral analysis was performed. The resonance frequency of a simple sound source was also recorded in water and air in order to evaluate the impact of the surrounding media. Results: Resonance frequencies from the sound source measured in air increased 14% compared with corresponding measurements in water. These data were used to correct findings from the five valves that showed different spectral characteristics in air. The frequency at which 97.5% of the signal energy was contained ranged from 40.9 to 65.8 kHz. Conclusion: Using an airflow in-vitro model, it was possible to determine the frequency signature of different mechanical heart valves. This might provide the information needed to design the optimal high-pass filter when evaluating cavitation.
引用
收藏
页码:736 / 744
页数:9
相关论文
共 50 条
  • [21] Design of a mechanical heart valve's occluder to start closing by gravity
    Naemura, K
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 1999, 42 (03): : 628 - 633
  • [22] Noise levels of closing sounds in vivo are equal for different bileaflet mechanical heart valves
    Johansen, P
    Hansen, SB
    Hasenkam, JM
    Nygaard, H
    JOURNAL OF HEART VALVE DISEASE, 2003, 12 (06): : 764 - 771
  • [23] MECHANICAL HEART SOUNDS
    不详
    LANCET, 1949, 257 (DEC17): : 1142 - 1142
  • [24] Spectral composition of heart sounds before and after mechanical heart valve implantation using a modified forward-backward Prony's method
    Sava, HP
    McDonnell, JTE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (07) : 734 - 742
  • [25] VALVE-CLOSING FUNCTION OF RIGHT ATRIUM - A STUDY OF PRESSURES AND ATRIAL SOUNDS IN PATIENTS WITH HEART BLOCK
    GRANT, C
    GREENE, DG
    BUNNELL, IL
    AMERICAN JOURNAL OF MEDICINE, 1963, 34 (03): : 325 - &
  • [26] A SQUEEZE FLOW PHENOMENON AT THE CLOSING OF A BILEAFLET MECHANICAL HEART-VALVE PROSTHESIS
    BLUESTEIN, D
    EINAV, S
    HWANG, NHC
    JOURNAL OF BIOMECHANICS, 1994, 27 (11) : 1369 - 1378
  • [27] Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase
    Cheon, G.-J.
    Chandran, K.B.
    Journal of Biomechanical Engineering, 1994, 116 (04) : 452 - 459
  • [28] Modifying a tilting disk mechanical heart valve design to improve closing dynamics
    Herbertson, Luke H.
    Deutsch, Steven
    Manning, Keefe B.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (05):
  • [29] SPECTRUM OF ARTIFICIAL VALVE HEART SOUNDS
    HARVEY, WP
    DELEON, AC
    HUFNAGEL, CA
    CIRCULATION, 1965, 32 (4S2) : 108 - &
  • [30] HEART SOUNDS AFTER VALVE REPLACEMENT
    LUISADA, AA
    RAFTERY, EB
    LUISADA, AA
    AMERICAN JOURNAL OF CARDIOLOGY, 1967, 20 (02): : 287 - &