Development of a simple test device for spindle error measurement using a position sensitive detector

被引:40
|
作者
Liu, CH [1 ]
Jywe, WY
Lee, HW
机构
[1] Natl Huwei Univ Sci & Technol, Inst Electroopt & Mat Sci, Yunlin 632, Taiwan
[2] Natl Huwei Univ Sci & Technol, Dept Automat Engn, Yunlin 632, Taiwan
[3] Chien Kuo Technol Univ, Inst Mechtronopt Syst, Changhua 500, Taiwan
关键词
rotation accuracy; spindle error; position sensitive detector; axis of rotation;
D O I
10.1088/0957-0233/15/9/009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new spindle error measurement system has been developed in this paper. It employs a design development rotational fixture with a built-in laser diode and four batteries to replace a precision reference master ball or cylinder used in the traditional method. Two measuring devices with two position sensitive detectors (one is designed for the measurement of the compound X-axis and Y-axis errors and the other is designed with a lens for the measurement of the tilt angular errors) are fixed on the machine table to detect the laser point position from the laser diode in the rotational fixture. When the spindle rotates, the spindle error changes the direction of the laser beam. The laser beam is then divided into two separated beams by a beam splitter. The two separated beams are projected onto the two measuring devices and are detected by two position sensitive detectors, respectively. Thus, the compound motion errors and the tilt angular errors of the spindle can be obtained. Theoretical analysis and experimental tests are presented in this paper to separate the compound errors into two radial errors and tilt angular errors. This system is proposed as a new instrument and method for spindle metrology.
引用
收藏
页码:1733 / 1741
页数:9
相关论文
共 50 条
  • [31] Development and Characterization of a Position Sensitive Neutron Scintillation Detector using Digital Silicon Photomultipliers
    Herzkamp, Matthias
    Durini, Daniel
    Degenhardt, Carsten
    Erven, Andreas
    Noeldgen, Holger
    Feoktystov, Artem
    Jokhovets, Liubov
    Streun, Matthias
    van Waasen, Stefan
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [32] Radiation measurement and imaging using 3D position sensitive pixelated CZT detector
    Kim, Younghak
    Lee, Taewoong
    Lee, Wonho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (05) : 1417 - 1427
  • [33] Influence of detector misalignment on the Ω assembly X-ray stress measurement using a position sensitive proportional counter as a detector
    Goto, Toru
    Gong, Yu
    Zairyo/Journal of the Society of Materials Science, Japan, 2002, 51 (07) : 764 - 770
  • [34] Three Degrees-of-Freedom Optical Spindle Error Motion Measurement Device
    Lee, Hau-Wei
    Chen, Jr-Rung
    Ho, Bing-Lin
    Wang, Chi-Chang
    SENSORS AND MATERIALS, 2017, 29 (11) : 1471 - 1481
  • [35] Quantitative phase imaging by using a position sensitive detector
    Soldevila, F.
    Duran, V.
    Clemente, P.
    Lancis, J.
    Tajahuerce, E.
    UNCONVENTIONAL OPTICAL IMAGING, 2018, 10677
  • [36] Development of High-Counting-Rate Measurement System for 3He Position Sensitive Detector
    Makino, S.
    Sumita, A.
    Onodera, T.
    Tanaka, Y.
    Hikida, N.
    Ishizawa, K.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 202 - +
  • [37] A SIMPLE AND RELIABLE SYSTEM FOR MEASURING THE REFRACTIVE-INDEX OF LIQUIDS USING A POSITION-SENSITIVE DETECTOR
    DOCCHIO, F
    CORINI, S
    PERINI, M
    KASANA, RS
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (01) : 68 - 70
  • [38] Measurement of spindle rotation induced error using the cross grid encoder test and its performance research
    Du, ZC
    Yang, JG
    Su, H
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2004, : 1217 - 1221
  • [39] Measurement of lymphedema using a simple device
    Imran, D
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 113 (01) : 456 - 457
  • [40] TEST-RESULTS FROM A POSITION-SENSITIVE NAI DETECTOR
    BASSALLECK, B
    HASINOFF, MD
    SALOMON, M
    NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (2-3): : 389 - 393