Quality assurance of I-125 seeds for prostate brachytherapy using an imaging plate

被引:11
|
作者
Furutani, Shunsuke
Saze, Takuya
Ikushima, Hitoshi
Oita, Masataka
Ozaki, Kyousuke
Kishida, Yoshlomi
Takegawa, Yoshihiro
Nishitani, Hiromu
机构
[1] Univ Tokushima, Dept Radiol, Tokushima 7708503, Japan
[2] Univ Tokushima, Radiosotope Res Ctr, Tokushima 7708503, Japan
[3] Univ Tokushima, Dept Hlth Sci, Tokushima 7708503, Japan
关键词
I-125; seed; cartridge; imaging plate; quality assurance; prostate brachytherapy;
D O I
10.1016/j.ijrobp.2006.05.052
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: OncoSeed is delivered in a sterile environment in the form of a cartridge, so it is impractical to resterilize and reload seeds after calibration. We investigated a new method using an imaging plate dosimetry system to characterize all seeds in the OncoSeed cartridge in a sterile environment. Methods and Materials: Seeds within the cartridge were placed on an imaging plate, and the imaging plate irradiated. To remove scatter radiation, and improve spatial resolution of seed images, we used X-ray parallel cross grids. The irradiated imaging plate was scanned using a Bio-imaging Analyzer System, and radioactivity intensities of seed images were given in counts. Counts could be translated to profiles, and each seed within the cartridge was analyzed. Results: Results showed a good correlation between counts and total radioactivity of the seeds within the cartridge. Thus, using a least-squares line, it was possible to characterize a cartridge with unknown apparent activity. By analyzing the profiles, it was possible not only to detect a miscalibrated seed in the cartridge from its relative difference in counts, but also to identify its position in the cartridge. No significant changes in counts were seen between sterile and nonsterile environments. Conclusion: Using an imaging plate dosimetry system, all seeds in a cartridge could be characterized in a sterile environment. (c) 2006 Elsevier Inc.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 50 条
  • [41] Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET
    Mason, J.
    Al-Qaisieh, B.
    Bownes, P.
    Henry, A.
    Thwaites, D.
    MEDICAL PHYSICS, 2013, 40 (03)
  • [42] Quality control of 125I-brachytherapy seeds
    Sanjay Kumar Saxena
    Yogendra Kumar
    Ashutosh Dash
    Journal of Radioanalytical and Nuclear Chemistry, 2012, 294 : 171 - 177
  • [43] PULMONARY EMBOLIZATION OF I-125 SEEDS FOLLOWING PROSTATE IMPLANTATION
    STEINFELD, AD
    DONAHUE, BR
    PLAINE, L
    UROLOGY, 1991, 37 (02) : 149 - 150
  • [44] Quality control of 125I-brachytherapy seeds
    Saxena, Sanjay Kumar
    Kumar, Yogendra
    Dash, Ashutosh
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 294 (02) : 171 - 177
  • [45] Ten year patient reported Quality of Life following I-125 prostate brachytherapy monotherapy
    Henry, A.
    Sethugavalar, B.
    Witteveen, T.
    Al-Qaisieh, B.
    Bownes, P.
    Smith, J.
    Carey, B.
    Franks, K.
    Mitchell, D.
    Bottomley, D.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S475 - S475
  • [46] Quality assurance of Pd-103 and I-125 seeds in the new shielded disposable mick cartridge
    Trichter, S
    Sabbas, A
    Kulidzhanov, F
    Nori, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1430 - 1430
  • [47] QUALITY ASSURANCE OF IODINATED (I-125) HUMAN-FIBRINOGEN
    VINES, EJ
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1981, 11 (05): : 574 - 574
  • [48] Dosimetric Study of Cs-131, I-125, and Pd-103 Seeds for Permanent Prostate Brachytherapy
    Yang, Ruijie
    Wang, Junjie
    Zhang, Hongzhi
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2009, 24 (06) : 701 - 705
  • [49] AUTORADIOGRAPHY FOR I-125 SEEDS
    ALBERTI, W
    DIVOUX, S
    POTHMANN, B
    TABOR, P
    HERMANN, KP
    HARDER, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (05): : 881 - 884
  • [50] Refining prostate seed brachytherapy: Comparing high-, intermediate-, and low-activity, seeds for I-125 permanent seed prostate brachytherapy
    Delouya, Guila
    Bahary, Pascal
    Carrier, Jean-Francois
    Larouche, Renee-Xaviere
    Hervieux, Yannick
    Beliveau-Nadeau, Dominic
    Donath, David
    Taussky, Daniel
    BRACHYTHERAPY, 2015, 14 (03) : 329 - 333