Geometry-based pressure drop prediction in mildly diseased human coronary arteries

被引:25
|
作者
Schrauwen, J. T. C. [1 ]
Wentzel, J. J. [1 ]
van der Steen, A. F. W. [1 ]
Gijsen, F. J. H. [1 ]
机构
[1] Erasmus MC, Dept Biomed Engn, NL-3000 CA Rotterdam, Netherlands
关键词
Coronary arteries; Pressure drop prediction; FFR; Atherosclerosis; CFD; FRACTIONAL FLOW RESERVE; WALL SHEAR-STRESS; BLOOD-FLOW; INTRAVASCULAR ULTRASOUND; COMPUTED-TOMOGRAPHY; FUNCTIONAL SEVERITY; PLAQUE BURDEN; STENOSES; ANGIOGRAPHY; VALIDATION;
D O I
10.1016/j.jbiomech.2014.03.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pressure drop (Delta p) estimations in human coronary arteries have several important applications, including determination of appropriate boundary conditions for CFD and estimation of fractional flow reserve (FFR). In this study a Delta p prediction was made based on geometrical features derived from patient-specific imaging data. Twenty-two mildly diseased human coronary arteries were imaged with computed tomography and intravascular ultrasound. Each artery was modelled in three consecutive steps: from straight to tapered, to stenosed, to curved model. CFD was performed to compute the additional Delta p in each model under steady flow for a wide range of Reynolds numbers. The correlations between the added geometrical complexity and additional Delta p were used to compute a predicted Delta p. This predicted Delta p based on geometry was compared to CFD results. The mean Delta p calculated with CFD was 855 +/- 666 Pa. Tapering and curvature added significantly to the total Delta p, accounting for 31.4 +/- 19.0% and 18.0 +/- 10.9% respectively at Re = 250. Using tapering angle, maximum area stenosis and angularity of the centerline, we were able to generate a good estimate for the predicted Delta p with a low mean but high standard deviation, average error of 41.1 +/- 287.8 Pa at Re = 250. Furthermore, the predicted Delta p was used to accurately estimate FFR (r=0.93). The effect of the geometric features was determined and the pressure drop in mildly diseased human coronary arteries was predicted quickly based solely on geometry. This pressure drop estimation could serve as a boundary condition in CFD to model the impact of distal epicardial vessels. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1810 / 1815
页数:6
相关论文
共 50 条
  • [41] Mine Geometry-Based Prediction of Tectonic Faults in Coal Seam in Extraction Panel
    Shaklein, S. V.
    Rogova, T. B.
    JOURNAL OF MINING SCIENCE, 2022, 58 (04) : 541 - 547
  • [42] Geometry-based Block Partitioning for Efficient Intra Prediction in Depth Video Coding
    Kang, Min-Koo
    Lee, Jaejoon
    Lee, Jin Young
    Ho, Yo-Sung
    VISUAL INFORMATION PROCESSING AND COMMUNICATION, 2010, 7543
  • [43] Mine Geometry-Based Prediction of Tectonic Faults in Coal Seam in Extraction Panel
    S. V. Shaklein
    T. B. Rogova
    Journal of Mining Science, 2022, 58 : 541 - 547
  • [44] Registering imaged ECoG electrodes to human cortex: A geometry-based technique
    Brang, David
    Dai, Zhongtian
    Zheng, Weili
    Towle, Vernon L.
    JOURNAL OF NEUROSCIENCE METHODS, 2016, 273 : 64 - 73
  • [45] An Outflow Boundary Condition Model for Noninvasive Prediction of Fractional Flow Reserve in Diseased Coronary Arteries
    Fayssal, Iyad A.
    Moukalled, Fadl
    Alam, Samir
    Isma'eel, Hussain
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (04):
  • [46] Ice pressure distribution model: A geometry-based solution for high-pressure zone representation
    Andrade, S. L.
    Gagnon, R.
    Colbourne, B.
    Quinton, B. W.
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2023, 210
  • [47] Investigation into a geometry-based model for surface roughness prediction in vibratory finishing processes
    E. Uhlmann
    A. Dethlefs
    A. Eulitz
    The International Journal of Advanced Manufacturing Technology, 2014, 75 : 815 - 823
  • [48] Investigation into a geometry-based model for surface roughness prediction in vibratory finishing processes
    Uhlmann, E.
    Dethlefs, A.
    Eulitz, A.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 75 (5-8): : 815 - 823
  • [49] DILTIAZEM ALONE AND COMBINED WITH NITROGLYCERIN - EFFECT ON NORMAL AND DISEASED HUMAN CORONARY-ARTERIES
    HESS, OM
    NONOGI, H
    BORTONE, A
    GAGE, JE
    GRIMM, J
    KRAYENBUEHL, HP
    EUROPEAN HEART JOURNAL, 1989, 10 : 142 - 146
  • [50] Pressure-Diameter Relationship in Human Coronary Arteries
    Muller, Olivier
    Pyxaras, Stylianos A.
    Trana, Catalina
    Mangiacapra, Fabio
    Barbato, Emanuele
    Wijns, William
    Taylor, Charles A.
    De Bruyne, Bernard
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (06) : 791 - 796