RETRACTED: Measuring DBD main discharge parameters using Q-V Lissajous figures (Retracted Article)

被引:3
|
作者
Cai Yi-xi [1 ]
Zhang Le-fu [1 ]
Wang Jun [1 ]
Ran Dong-li [1 ]
Wang Jing [1 ]
机构
[1] Jiangsu Univ, Sch Automot & Traff Engn, Zhenjiang, Peoples R China
关键词
dielectric barrier discharge; Q-V Lissajous figure; applied voltage; applied frequency;
D O I
10.1109/APPEEC.2010.5449431
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Through establishing dielectric barrier discharge (DBD) experiment system, the effects of applied voltage (V) and its frequency (f) on the main parameters of DBD were studied by Q-V Lissajous figures method. some conclusions could be drawn that improving V and f effectively enhanced DBD power(P) and charge transfer value(Q); when DBD device structure parameters were certain, the effects of V and f on the total equivalent capacitance(C) was little, dielectric equivalent capacitance(Cd) increased with the increase of V and f, equivalent capacitance of the discharge gap(Cg) slightly decreased with the increase of V and f; the effective electric field of the discharge gap(Eg) increased with the increase of V, the effects of f on Eg was little; the average electron energy of the DBD device was high and could be used to the equipment such as O-3 generator.