A photopolymerized composite hydrogel and surgical implanting tool for a nucleus pulposus replacement

被引:54
|
作者
Schmocker, Andreas [1 ,2 ]
Khoushabi, Azadeh [1 ,3 ]
Frauchiger, Daniela A. [4 ]
Gantenbein, Benjamin [4 ]
Schizas, Constantin [5 ]
Moser, Christophe [2 ]
Bourban, Pierre-Etienne [3 ]
Pioletti, Dominique P. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Bioengn, Lab Biomech Orthoped, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Inst Microengn, Lab Appl Photon Devices, CH-1015 Lausanne, Switzerland
[3] Ecole Polytech Fed Lausanne, Inst Mat, Lab Polymer & Composite Technol, CH-1015 Lausanne, Switzerland
[4] Univ Bern, Inst Surg Technol & Biomech, Tissue & Organ Mechanobiol, Bern, Switzerland
[5] CHU Vaudois, Dept Orthoped, CH-1011 Lausanne, Switzerland
关键词
Medical device; poly(ethylene-glycol)dimethacrylate; Minimally invasive surgery; Nano-cellulose fibers; Orthopedic implant; Photopolymerization; LOW-BACK-PAIN; INTERVERTEBRAL DISC DEGENERATION; POLY(ETHYLENE GLYCOL) HYDROGELS; MECHANICAL-PROPERTIES; LUMBAR DISC; ANIMAL-MODELS; COMPRESSION; PROSTHESIS; PUNCTURE; FUSION;
D O I
10.1016/j.biomaterials.2016.02.015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nucleus pulposus replacements have been subjected to highly controversial discussions over the last 40 years. Their use has not yet resulted in a positive outcome to treat herniated disc or degenerated disc disease. The main reason is that not a single implant or tissue replacement was able to withstand the loads within an intervertebral disc. Here, we report on the development of a photo-polymerizable poly(ethylene glycol)dimethacrylate nano-fibrillated cellulose composite hydrogel which was tuned according to native tissue properties. Using a customized minimally-invasive medical device to inject and photopolymerize the hydrogel insitu, samples were implanted through an incision of 1 mm into an intervertebral disc of a bovine organ model to evaluate their long-term performance. When implanted into the bovine disc model, the composite hydrogel implant was able to significantly re-establish disc height after surgery (p < 0.0025). The height was maintained after 0.5 million loading cycles (p < 0.025). The mechanical resistance of the novel composite hydrogel material combined with the minimally invasive implantation procedure into a bovine disc resulted in a promising functional orthopedic implant for the replacement of the nucleus pulposus. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 50 条
  • [31] The effect of dehydration history on associating hydrogels for nucleus pulposus replacement
    Gomes, K
    Thomas, J
    Lowman, A
    Marcolongo, M
    PROCEEDINGS OF THE IEEE 28TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2002, : 257 - 258
  • [32] Polyurethane scaffold with in situ swelling capacity for nucleus pulposus replacement
    Li, Zhen
    Lang, Gernot
    Chen, Xu
    Sacks, Hagit
    Mantzur, Carmit
    Tropp, Udi
    Mader, Kerstin T.
    Smallwood, Thomas C.
    Sammon, Chris
    Richards, R. Geoff
    Alini, Mauro
    Grad, Sibylle
    BIOMATERIALS, 2016, 84 : 196 - 209
  • [33] The performance of a hydrogel nucleus pulposus prosthesis in an ex vivo canine model
    Bergknut, Niklas
    Smolders, Lucas A.
    Koole, Leo H.
    Voorhout, George
    Hagman, Ragnvi E.
    Lagerstedt, Anne-Sofie
    Saralidze, Ketie
    Hazewinkel, Herman A. W.
    van der Veen, Albert J.
    Meij, Bjorn P.
    BIOMATERIALS, 2010, 31 (26) : 6782 - 6788
  • [34] In situ forming macroporous biohybrid hydrogel for nucleus pulposus cell delivery
    Brissenden, Amanda J.
    Amsden, Brian G.
    ACTA BIOMATERIALIA, 2023, 170 : 169 - 184
  • [35] Characterisation of porous knitted titanium for replacement of intervertebral disc nucleus pulposus
    Gauri Tendulkar
    Vrinda Sreekumar
    Frank Rupp
    Arun K. Teotia
    Kiriaki Athanasopulu
    Ralf Kemkemer
    Alfred Buck
    Alfred Buck
    Hans-Peter Kaps
    Jürgen Geis-Gerstorfer
    Ashok Kumar
    Andreas K. Nussler
    Scientific Reports, 7
  • [36] The effect of dehydration history on PVA/PVP hydrogels for nucleus pulposus replacement
    Thomas, J
    Gomes, K
    Lowman, A
    Marcolongo, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 69B (02) : 135 - 140
  • [37] Developing a novel functional disc emulator to investigate the nucleus pulposus replacement
    Hassan M. Raheem
    Skip E. Rochefort
    Brian K. Bay
    Journal of Materials Science: Materials in Medicine, 2021, 32
  • [38] Photopolymerization device for minimally invasive implants: application to nucleus pulposus replacement
    Schmocker, A.
    Khoushabi, A.
    Bourban, P. E.
    Pioletti, D. P.
    Moser, C.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 1333 - 1337
  • [39] Biocomposite Hydrogels with Carboxymethylated, Nanofibrillated Cellulose Powder for Replacement of the Nucleus Pulposus
    Eyholzer, C.
    de Couraca, A. Borges
    Duc, F.
    Bourban, P. E.
    Tingaut, P.
    Zirnmermann, T.
    Manson, J. A. E.
    Oksman, K.
    BIOMACROMOLECULES, 2011, 12 (05) : 1419 - 1427
  • [40] Characterisation of porous knitted titanium for replacement of intervertebral disc nucleus pulposus
    Tendulkar, Gauri
    Sreekumar, Vrinda
    Rupp, Frank
    Teotia, Arun K.
    Athanasopulu, Kiriaki
    Kemkemer, Ralf
    Buck, Alfred, Jr.
    Buck, Alfred, Sr.
    Kaps, Hans-Peter
    Geis-Gerstorfer, Juergen
    Kumar, Ashok
    Nussler, Andreas K.
    SCIENTIFIC REPORTS, 2017, 7