Background. Healing of tibial fractures treated by locked nailing is threatened by locking screw failure. However, the effects of the design factors of the screws on their mechanical strength have rarely been studied. Method. Three-point bending tests and finite element analyses were used to investigate the bending strength of five types of commercially available tibial locking screws and two types of specially designed screws. Yielding strength and fatigue life measured in bending tests were correlated to total strain energy and maximal tensile stress computed in finite element analyses. Parametric analysis and design optimization were done according to the Taguchi method. Validation studies to assess the stress rising effect of the threads on the fatigue strength were conducted in two types of new screws made of either stainless steel or titanium alloy. Findings. The yielding strength of the screws was closely related to their total strain energy, and the logarithm of the fatigue life was closely related to the maximal tensile stress with correlation coefficients of -0.95 and -0.90, respectively. Parametric studies indicated that fatigue strength of the screws was affected mainly by inner diameter (contribution, 63.8%) and root radius (27.8%). The yielding strength was determined primarily by inner diameter (88.5%). Titanium screws had a longer fatigue life than stainless steel screws, especially in screws with larger root radii. Interpretation. A screw's strength is closely related to its design factors. Finite element models, which can reliably reflect the mechanical strength of screws can save time and effort during screw design. Larger root radius can effectively improve the fatigue strength, especially for titanium screws as compared with stainless steel screws. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [1] Increasing bending strength and pullout strength in conical pedicle screws: Biomechanical tests and finite element analyses
    Chao, Ching-Kong
    Hsu, Ching-Chi
    Wang, Jaw-Lin
    Lin, Jinn
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (02): : 130 - 138
  • [2] Mechanical tests and finite element models for bone holding power of tibial locking screws
    Hou, SM
    Hsu, CC
    Wang, JL
    Chao, CK
    Lin, J
    CLINICAL BIOMECHANICS, 2004, 19 (07) : 738 - 745
  • [3] Pushout strength of tibial locking screws: Development of finite element models
    Hsu, CC
    Wang, JL
    Hou, SM
    Chao, CK
    Lin, J
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2003, 26 (06) : 817 - 823
  • [4] Bending strength and holding power of tibial locking screws
    Lin, J
    Lin, SJ
    Chiang, HS
    Hou, SM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (385) : 199 - 206
  • [5] Comparison of the bending performance of solid and cannulated spinal pedicle screws using finite element analyses and biomechanical tests
    Shih, Kao-Shang
    Hsu, Ching-Chi
    Hou, Sheng-Mou
    Yu, Shan-Chuen
    Liaw, Chen-Kun
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (09) : 879 - 884
  • [6] Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses
    Hsu, CC
    Chao, CK
    Wang, JL
    Hou, SM
    Tsai, YT
    Lin, J
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) : 788 - 794
  • [7] Mechanical strength, fatigue life, and failure analysis of two prototypes and five conventional tibial locking screws
    Hou, SM
    Wang, JL
    Lin, J
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (10) : 701 - 708
  • [8] Fatigue strength of common tibial intramedullary nail distal locking screws
    Griffin L.V.
    Harris R.M.
    Zubak J.J.
    Journal of Orthopaedic Surgery and Research, 4 (1)
  • [9] Bending strength and holding power of a prototype tibial locking screw
    Lin, J
    Hou, SM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (403) : 232 - 239
  • [10] Finite element analyses of Ilizarov tibial fixators
    Nagesh, HS
    Menon, D
    Chandrasekharan, MP
    Pillai, TMM
    STRUCTURAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 1999, : 1537 - 1542