Fatigue strength of common tibial intramedullary nail distal locking screws

被引:21
|
作者
Griffin L.V. [1 ]
Harris R.M. [2 ]
Zubak J.J. [3 ]
机构
[1] California Polytechnic State University, Biomedical and General Engineering, San Luis Obispo, CA
[2] Orthopaedic Trauma, Holston Valley Medical Center, Wellmont Health System, Kingsport, TN
[3] Shannon Clinic Southwest, San Angelo, TX
关键词
Fatigue Life; Intramedullary Nail; Full Weight Bearing; Hardware Failure; High Cycle Fatigue;
D O I
10.1186/1749-799X-4-11
中图分类号
学科分类号
摘要
Background. Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8-10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative and qualitative measures of the relative performance of these screws. Methods. Fatigue tests were conducted to simulate a comminuted fracture that was treated by IM nailing assuming that all load was carried by the screws. Each screw type was tested ten times in a single screw configuration. One screw type was tested an additional ten times in a two-screw parallel configuration. Fatigue tests were performed using a servohydraulic materials testing system and custom fixturing that simulated screws placed in the distal region of an appropriately sized tibial IM nail. Fatigue loads were estimated based on a seventy-five kilogram individual at full weight bearing. The test duration was one million cycles (roughly one year), or screw fracture, whichever occurred first. Failure analysis of a representative sample of titanium alloy and stainless steel screws included scanning electron microscopy (SEM) and quantitative metallography. Results. The average fatigue life of a single screw with a diameter of 4.0 mm was 1200 cycles, which would correspond roughly to half a day of full weight bearing. Single screws with a diameter of 4.5 mm or larger have approximately a 50 percent probability of withstanding a week of weight bearing, whereas a single 5.0 mm diameter screw has greater than 90 percent probability of withstanding more than a week of weight bearing. If two small diameter screws are used, our tests showed that the probability of withstanding a week of weight bearing increases from zero to about 20 percent, which is similar to having a single 4.5 mm diameter screw providing fixation. Conclusion. Our results show that selecting the system that uses the largest distal locking screws would offer the best fatigue resistance for an unstable fracture pattern subjected to full weight bearing. Furthermore, using multiple screws will substantially reduce the risk of premature hardware failure.
引用
收藏
相关论文
共 50 条
  • [1] Distal Locking Screws for Intramedullary Nailing of Tibial Fractures
    Agathangelidis, Filon
    Petsatodis, Georgios
    Kirkos, John
    Papaapadopoulos, Pericles
    Karataglis, Dimitrios
    Christodoulou, Anastasios
    ORTHOPEDICS, 2016, 39 (02) : E253 - E258
  • [2] Placement of the distal locking screws of the femoral intramedullary nail without radiation
    Steriopoulos, KA
    Kontakis, GM
    Katonis, PG
    Galanakis, IA
    Dretakis, EK
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1996, 115 (01) : 43 - 44
  • [3] Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union
    Aso Mohammed
    Ramaswamy Saravanan
    Jason Zammit
    Richard King
    International Orthopaedics, 2008, 32 : 547 - 549
  • [4] Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union
    Mohammed, Aso
    Saravanan, Ramaswamy
    Zammit, Jason
    King, Richard
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (04) : 547 - 549
  • [5] Intramedullary locked nail for distal tibial fracture
    Bonnevialle, P
    Savorit, L
    Combes, JM
    Rongieres, M
    Bellumore, Y
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1996, 82 (05): : 428 - 436
  • [6] Technique for Guiding Distal Locking Screws into Intramedullary Nails
    Stevens, Jarrad M.
    Shiel, Sarah
    Chesser, Timothy
    TECHNIQUES IN ORTHOPAEDICS, 2021, 36 (02) : 188 - 189
  • [7] A technique for removal of fractured locking screws from an intramedullary nail
    Davies, NM
    Farnell, RD
    Unwin, AJ
    Jones, JR
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (02): : 159 - 159
  • [8] Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail
    Persiani P.
    Gurzi M.
    Moreschini O.
    Di Giacomo G.
    Villani C.
    MUSCULOSKELETAL SURGERY, 2017, 101 (1) : 19 - 23
  • [9] Nail over nail technique for distal locking of femoral intramedullary nails
    Rohilla, Rajesh
    Singh, Roop
    Magu, Narender
    Devgun, Ashish
    Siwach, Ramchander
    Gulia, Ashish
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 1107 - 1112
  • [10] Nail over nail technique for distal locking of femoral intramedullary nails
    Rajesh Rohilla
    Roop Singh
    Narender Magu
    Ashish Devgun
    Ramchander Siwach
    Ashish Gulia
    International Orthopaedics, 2009, 33