Simultaneous determination of 9 preservatives in processed foods using high-performance liquid chromatography with photo diode array detector

被引:2
|
作者
Lee, Do-Yeon [2 ]
Kim, Min-Hee [3 ]
Ahn, Jang-Hyuk [1 ]
机构
[1] CHA Univ, Dept Food Sci & Biotechnol, Pochon 11160, South Korea
[2] Dongguk Univ, Dept Food Sci & Biotechnol, Goyang 410820, South Korea
[3] Korea Univ, Dept Integrated Biomed & Life Sci, Seoul 02841, South Korea
来源
ANALYTICAL SCIENCE AND TECHNOLOGY | 2020年 / 33卷 / 06期
关键词
preservatives; carrez reagent; simultaneous determination; processed foods; BENZOIC-ACID; DAIRY-PRODUCTS; SORBIC ACID;
D O I
10.5806/AST.2020.33.6.233
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study was performed to develop an analytical method using Carrez reagents as the precipitant to effectively and easily remove proteins and lipids while pretreating samples for the simultaneous determination of preservatives, including dehydroacetic acid (DHA), sorbic acid (SA), benzoic acid (BA), methyl rho-hydroxybenzoate (MP), ethyl rho-hydroxybenzoate (EP), propyl rho-hydroxybenzoate (PP), isopropyl rho-hydroxybenzoate (IPP), butyl rho-hydroxybenzoate (BP), and isobutyl rho-hydroxybenzoate (IBP). The effective selectivity was determined by HPLC separation analysis for nine preservatives in the test solution, after removing interfering materials such as lipids and proteins. The method developed in this study showed excellent linearity at 0.999 or higher. The limit of detection (LOD) ranged from 0.09 to similar to 0.12 mg/L and the limit of quantitation (LOQ) was similar to 0.280.37 mg/L. The results of the recovery test on processed foods, including pickles, cheeses, processed meat products, beverages, sauces, and emulsified foods showed DHA, SA, BA, MP, EP, IPP, PP, IBP, and BP at 90.9 similar to 107.7 %, 85.4 similar to 113.7 %, 90.7 similar to 111.6 %, 84.5 similar to 111.2 %, 81.3 similar to 110.9 %, 82.5 similar to 102.2 %, 81.1 similar to 110.0 %, 80.9 similar to 109.0 %, and 82.4 similar to 110.3 %, respectively. The probability of the simultaneous analytical method developed in this study as a quantitative method was confirmed for various processed foods.
引用
下载
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [41] DETERMINATION OF FOOD PRESERVATIVES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NAKAGUMA, H
    TAJIMA, K
    KONISHI, T
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1985, 31 (01): : 32 - 36
  • [42] DETERMINATION OF 9 PHENOLIC ANTIOXIDANTS IN FOODS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    YAMADA, M
    MIYATA, M
    KATO, Y
    NAKAMURA, M
    NISHIJIMA, M
    SHIBATA, T
    ITO, Y
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1993, 34 (06): : 535 - 541
  • [43] Simultaneous Determination of Eight Preservatives in Feeds by High Performance Liquid Chromatography
    Gao, Wen-Hui
    Cao, Xiao-Mei
    Han, Jun-Hua
    Li, Xing-Feng
    Jia, Ying-Min
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (14) : 4162 - 4166
  • [44] Simultaneous quantitation of eight active components in crude and processed Radix Scrophulariae extracts by high performance liquid chromatography with diode array detector
    Cao Gang
    Cong Xiao-Dong
    Cai Hao
    Li Xiao-Meng
    Ji Jin-Yu
    Zhang Yun
    Cai Bao-Chang
    CHINESE JOURNAL OF NATURAL MEDICINES, 2012, 10 (03): : 213 - 217
  • [45] Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry
    Hostetler, KA
    Thurman, EM
    SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 248 (2-3) : 147 - 155
  • [46] The use of high-performance liquid chromatography with diode array detector for the determination of sulfide ions in human urine samples using pyrylium salts
    Zgagacz, W.
    Zakrzewski, R.
    Urbaniak, K.
    Chwatko, G.
    Nowicki, A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1157
  • [47] Determination of anthraquinones in Rhamnus purshiana using high-performance liquid chromatography coupled to diode array detector and simple ultraviolet spectroscopic analysis
    Migues, Vitor Hugo
    Mauricio, Jorge
    Gomes, Angelica Ferraz
    David, Juceni Pereira
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (14) : 2478 - 2487
  • [48] Determination of phylloquinone in foods by high-performance liquid chromatography
    Booth, SL
    Sadowski, JA
    VITAMINS AND COENZYMES, PT L, 1997, 282 : 446 - 456
  • [49] Simultaneous Determination of 10 Active Components in Hulisan Tablets by a High-Performance Liquid Chromatographic-Diode Array Detector
    Mao, Kun-jun
    Huang, Ping
    Li, Fu-qiang
    Li, Xiang
    Chen, Jian-wei
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (09) : 1449 - 1454
  • [50] Imatinib Quantification in Human Serum for Clinical Purposes using High-performance Liquid Chromatography with a Diode Array Detector
    Dziadosz, Marek
    Bartels, Heidemarie
    ACTA CHIMICA SLOVENICA, 2011, 58 (02) : 347 - 350