Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer

被引:3
|
作者
Steel, Jared [1 ]
Stewart, Allan [1 ]
Satory, Philip [1 ]
机构
[1] Auckland City Hosp, Auckland Reg Blood & Canc Serv, Auckland 1023, New Zealand
关键词
electron-photon beam matching; multileaf collimator; extended source-to-surface; head-and-neck; RADIATION-THERAPY; FIELDS;
D O I
10.1118/1.3187782
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Matching the penumbra of a 6 MeV electron beam to the penumbra of a 6 MV photon beam is a dose optimization challenge, especially when the electron beam is applied from an extended source-to-surface distance (SSD), as in the case of some head and neck treatments. Traditionally low melting point alloy blocks have been used to define the photon beam shielding over the spinal cord region. However, these are inherently time consuming to construct and employ in the clinical situation. Multileaf collimators (MLCs) provide a fast and reproducible shielding option but generate geometrically nonconformal approximations to the desired beam edge definition. The effects of substituting Cerrobend (R) for the MLC shielding mode in the context of beam matching with extended-SSD electron beams are the subject of this investigation. Methods: Relative dose beam data from a Varian EX 2100 linear accelerator were acquired in a water tank under the 6 MeV electron beam at both standard and extended-SSD and under the 6 MV photon beam defined by Cerroben (R) a and a number of MLC stepping regimes. The effect of increasing the electron beam SSD on the beam penumbra was assessed. MLC stepping was also assessed in terms of the effects on both the mean photon beam penumbra and the intraleaf dose-profile nonuniformity relative to the MLC midleaf. Computational techniques were used to combine the beam data so as to simulate composite relative dosimetry in the water tank, allowing fine control of beam abutment gap variation. Idealized volumetric dosimetry was generated based on the percentage depth-dose data for the beam modes and the abutment geometries involved. Comparison was made between each composite dosimetry dataset and the relevant ideal dosimetry dataset by way of subtraction. Results: Weighted dose-difference volume histograms (DDVHs) were produced, and these, in turn, summed to provide an overall dosimetry score for each abutment and shielding type/angle combination. Increasing the electron beam SSD increased the penumbra width (defined as the lateral distance of the 80% and 20% isodose contours) by 8-10 mm at the depths of 10-20 mm. Mean photon beam penumbra width increased with increased MLC stepping, and the mean MLC penumbra was approximate to 1.5 times greater than that across the corresponding Cerrobend (R) shielding. Intraleaf dose discrepancy in the direction orthogonal to the beam edge also increased with MLC stepping. Conclusions: The weighted DDVH comparison techniques allowed the composite dosimetry resulting from the interplay of the abovementioned variables to be ranked. The MLC dosimetry ranked as good or better than that resulting from beam matching with Cerrobend (R) for all except large field overlaps (-2.5 mm gap). The results for the linear-weighted DDVH comparison suggest that optimal MLC abutment dosimetry results from an optical surface gap of around 1 +/- 0.5 mm. Furthermore, this appears reasonably lenient to abutment gap variation, such as that arising from uncertainty in beam markup or other setup errors. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3187782]
引用
收藏
页码:4244 / 4249
页数:6
相关论文
共 50 条
  • [31] Mono-isocentric technique for photon and electron fields in treatment of head and neck cancer
    Luo, C
    Wu, X
    Shao, H
    Wen, B
    Huang, D
    Takita, C
    Wolfson, A
    Levy, R
    Krugh, K
    Markoe, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1217 - 1217
  • [32] Radiotherapy of breast cancer after breast-conserving surgery:: an improved technique using mixed electron-photon beams with a multileaf collimator
    Jansson, T
    Lindman, H
    Nygård, K
    Dahlgren, CV
    Montelius, A
    Öberg-Kreuger, C
    Asplund, S
    Bergh, J
    RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) : 83 - 89
  • [33] Evaluation of Flatening Filter Free (FFF) Beams in Radiotherapy of Head and Neck Cancer
    Wu, Q.
    Yoo, S.
    Das, S.
    Yin, F.
    MEDICAL PHYSICS, 2012, 39 (06) : 3834 - 3834
  • [34] Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation
    Ling, CC
    Burman, C
    Chui, CS
    Kutcher, GJ
    Leibel, SA
    LoSasso, T
    Mohan, R
    Bortfeld, T
    Reinstein, L
    Spirou, S
    Wang, XH
    Wu, QW
    Zelefsky, M
    Fuks, Z
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04): : 721 - 730
  • [35] Modeling of electron contamimation in clinical photon beams for Monte Carlo treatment planning
    Yang, J
    Li, JS
    Ma, CM
    MEDICAL PHYSICS, 2003, 30 (06) : 1515 - 1515
  • [36] Evaluation of radiation treatment plan quality in head and neck cancer: a comparative analysis of RapidArc technique with flattening filter and flattening filter-free photon beams
    Mishra, Atul
    Manna, Sumanta
    Mittal, Kailash Kumar
    Singh, Sharad
    Yadav, Neha
    ECANCERMEDICALSCIENCE, 2025, 19
  • [37] DOSIMETRIC EFFECTS OF ABUTTING EXTENDED SOURCE TO SURFACE DISTANCE ELECTRON FIELDS WITH PHOTON FIELDS IN THE TREATMENT OF HEAD AND NECK CANCERS
    JOHNSON, JM
    KHAN, FM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03): : 741 - 747
  • [38] ELECTRON-BEAM TREATMENT OF CANCER OF HEAD AND NECK
    TAPLEY, NDV
    ENT-EAR NOSE & THROAT JOURNAL, 1977, 56 (03) : 74 - +
  • [39] Potential of Very High Energy Electron ( FLASH) beams in pancreatic and head-and-neck treatments
    Muscato, A.
    Arsini, L.
    Campana, L.
    Carlotti, D.
    De Gregorio, A.
    De Felice, F.
    Di Felice, C.
    Fischetti, M.
    Fiore, M.
    Franciosini, G.
    Marafini, M.
    Mare, V.
    Mattei, I.
    Pacilio, M.
    Patera, V.
    Ramella, S.
    Schiavi, A.
    Sciubba, A.
    Schwarz, M.
    Toppi, M.
    Traini, G.
    Trigilio, A.
    Sarti, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S383 - S385
  • [40] Testing the adjustment of photon counterfields and electron fields in irradiation of head and neck cancer
    Hierholz, K
    Baus, W
    Kober, B
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 69 - 69